INSTALLATION AND MAINTENANCE INSTRUCTIONS
3825 Ohio Avenue, St. Charles, Illinois 60174
MP120K 120 VAC Adapter Mounting Plate
SPECIFICATIONS
General Specifications
Standard Operating Temperature: –40°F to 151°F (–40°C to 66°C)
Humidity Range: 10 to 93% non-condensing (indoor products)
Nominal Voltage: Regulated 120 VAC
Operating Voltage Range: 96-132 VAC
Current Draw From AC Line: 150 mA max.
MP120K may be used with any of the following products, at all horn and strobe settings:
P2R, P2RH, P2RK, P2RHK, P2W, P2WH, SR, SRH, SRK, SRHK, SW, SWH, PC2R, PC2RH, PC2RK, PC2RHK, PC2W, PC2WH, SCR, SCRH, SCRK, SCRHK, SCW,
SCWH, HR, HRK, HW, SR-P, SW-P, SRH-P, SWH-P, P2R-P, P2W-P, P2RH-P, P2WH-P, SCR-P, SCW-P, SCRH-P, SCWH-P, PC2R-P, PC2W-P, PC2RH-P, PC2WH-P,
SR-SP, SRH-SP, P2R-SP, P2RH-SP, SCW-SP, SCWH-SP, PC2W-SP, PC2WH-SP, CHR, CHW, CHSR, CHSW
GENERAL DESCRIPTION
The MP120K mounting plate is designed to allow the use of 120 VAC to power
SpectrAlert Advance horns, strobes, horns/strobes, chimes, and chime/strobes.
The MP120K consists of a SpectrAlert Advance mounting plate that has been
fitted with a power supply that converts 120VAC to nominal 24V FWR.
The MP120K must be installed using a 120 VAC power source. This unit
can only be used for non-synchronous applications; it will NOT work with
SpecrtAlert Sync•Circuit Modules.
NOTICE: This manual shall be left with the owner/user of this equipment.
WIRING
This module has pig-tail wires and is intended to be wired without rigid connections inside a standard electrical box.
1.800.SENSOR2; Fax: 630.377.6495
www.systemsensor.com
I56-2877-005R
FIGURE 1. NON-SYNCHRONIZED DEVICES; ANY COMBINATION OF MODELS POWERED BY A 2-WIRE CIRCUIT.
Horn Horn/strobe
Strobe Only
120 VAC
Power
Two Wire System
An
Wired for Tandem
Operation
A0356-00
D640-01-00 1 I56-2877-005R
MOUNTING
FIGURE 2.
4 X 4 X 2 1/8 BACK BOX
MOUNTING (WALL OR CEILING)
120V WIRES
120V MOUNTING PLATE MP120K
A0357-00
1. For indoor applications, attach the mounting plate as shown in Figure 2.
The mounting plate is compatible only with 4 × 4 electrical boxes.
2. Connect field wiring. (For indoor models only)
3. If the product is not to be installed at this point, use the paint cover to
prevent contamination of the mounting plate.
4. To attach product to mounting plate, remove the paint cover, then hook
tabs on the product housing into the grooves on mounting plate.
5. Then, swing product into position to engage the pins on the product with
the terminals on the mounting plate. Make sure that the tabs on the back
of the product housing fully engage with the mounting plate.
6. Secure product by tightening the single mounting screw in the front
of the product housing. For tamper resistance, the standard captivated
mounting screw may be replaced with the enclosed Torx screw.
K SERIES MOUNTING
1. K Series products may be used indoors or outdoors. They must be installed using the proper SpectrAlert Advance weatherproof back box. Do
not attempt to use boxes other than the ones supplied with the product.
2. The plastic weatherproof back box is equipped with removable side
flanges for mounting. The back box may be secured directly to the wall
or ceiling using the flanges (plastic and metal back boxes) or by using
the knockout plugs(plastic back boxes). Knockout plugs are provided to
mount directly to the wall or ceiling or to a 1900 weatherproof electrical
box, see figure 3
3. The wall mount box must be mounted with its internal post in the lower
left corner, as shown in Figure 3.
4. Threaded holes are provided in the sides of the box for ¾ inch conduit
adapters. Knockout plugs in the back of the box can be used for ¾ inch
rear entry. Unused holes must be sealed. Plugs are provided with the box
for this purpose.
5. It is the responsibility of the installer to make sure that all openings and
connections are sealed properly. Outdoor installations that are protected
from direct exposure to rain are still subject to condensation or leakage
through hidden areas, such as a soffit.
6. Water may pool on the back box due to condensation or direct exposure
to rain or snow. Use watertight fittings for all wiring connections, including the knockout plugs on the back of the box. When using plastic plugs
to fill unused threaded holes, apply teflon tape and/or silicone sealant to
reduce the chance of leakage.
7. Attach the mounting plate to the weatherproof back box using the four
unpainted screws supplied.
8. Follow steps 1 – 6 of the indoor mounting instructions to wire and attach
the product.
FIGURE 3.
A0418-03
Please refer to insert for the Limitations of Fire Alarm Systems
THREE-YEAR LIMITED WARRANTY
System Sensor warrants its enclosed product to be free from defects in materials and
workmanship under normal use and service for a period of three years from date of
manufacture. System Sensor makes no other express warranty for this product. No agent,
representative, dealer, or employee of the Company has the authority to increase or alter
the obligations or limitations of this Warranty. The Company’s obligation of this Warranty
shall be limited to the replacement of any part of the product which is found to be defective in materials or workmanship under normal use and service during the three year
period commencing with the date of manufacture. After phoning System Sensor’s toll
free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Returns Department, RA #__________, 3825
FCC STATEMENT
SpectrAlert Strobes and Horn/Strobes have been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and
D640-01-00 2 I56-2877-005R
©2011 System Sensor
Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and
suspected cause of failure. The Company shall not be obligated to replace units which
are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable
for any consequential or incidental damages for breach of this or any other Warranty,
expressed or implied whatsoever, even if the loss or damage is caused by the Company’s
negligence or fault. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you. This
Warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.
can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.