Model S-6095-AC-12V, p/n SF-01399 (5¼" spout) ■ Model S-6098-AC-12V, p/n SF-01400 (8" spout)
Single
hole mount
Step 1
Attach faucet
to deck
Step 2
Connect water
supply line
nished deck
front view
Operation
Date Code
-nn = year
-11
Three
hole mount
with deck plate
Step 1
Attach faucet
and deck plate
to deck
Step 2
Connect water
supply line
supply
input
supply
input
AC
nished deck
front view
AC
Spout swivel modifications
120°
2.5 mm
remove all pins for 360º
60°
top view
top view
Installation Instructions, S-6095-AC-12V and S-6098-AC-12V
Important! Prior to connecting the water supply, ensure
supply lines are ushed. Particles can clog lter and result
in malfunction. Excessive particles from supply lines may
require installing a separate ecient lter.
Step 1 Attach faucet to deck (1 hole)
Single hole mount
nished deck
front view
Step 2 Connect power and supply line
™
strainer
check/
adapter
12 VDC
power
HOT
120 VAC
power outlet
Symmons MAXLINE
5-210 water temperature
limiting valve shown for
illustration if required.
temp
adjust
COLD
3/8"
1/2"
tempered supply output
Step 3 Test operation & check for leaks
Step 1 Attach faucet to deck (3 hole)
Three hole mount with deck plate
nished deck
front view
Operation
Sensor range: typically 1/2 to 10
inches
Place hands under faucet, water will ow
automatically for 10 seconds and shut o.
*******************************
Auto shut-off: 1/2 to 1 second
Remove hands, water will stop
automatically within 1/2 to 1 second.
*******************************
Security OFF: 10 seconds
Faucet will automatically shut o aer
continuous water ow for 10 seconds.
Page 2
Multi-Faucet Installation Instructions, S-6095-ACM-12V and S-6098-ACM-12V
+LEAD #1
-LEAD #2
Visual Install Guide
Multi-Faucets S-6095/6098-ACM-12V
+12 VDC
– RET (GND)
Input: 100 - 240 VAC47-63 Hz @ 1.0 amps
Standard 10 foot DC power cable (optional 20 foot) included with each faucet.
Power supply supportsup
to eight (8) Sensor Faucets
AWG #20
AWG #16
AWG #16
AWG #20
12 inch (305 mm) DC power cable
DC power receptacle
DC power cable plug
Model S-6244 (p/n SF-194)Termination Enclosure
Switching Power Supply Output: 12 VDC@ 3.33 amps max
Model S-6240-12V(p/n SF-01448)
Wire nut,terminate wires together
Wire nut,terminate wires together
green-yellow...(Protective earth)
blue................ (Neutral)
brown............. (Line)
wire labels
+LEAD #1 = +12 VDC
-LEAD #2 = -RET (GND)
Installation Requirements
e following items are not
included and purchased separately:
Switching Powers Supply,
Model# S-6240-12V
Power Supply supports up to eight
faucets. Mounting strap and screws
are included.
Standard electrical termination
enclosure or equivalent
(6"H x 10"H x 4"D).
Model S-6244 enclosure box may
be purchased from Symmons or
similar type from a local electrical
supplier.
Page 3
Wire nuts - Secure wire connections
using two wire nuts that can join (8)
AWG #20 wires and (1) AWG #16
wire. Purchace from a local electrical
supplier.
Electrical Installation
120/240 VAC to 12 VDC power
supply must be mounted in a
electrical termination enclosure box
with wire connection in accordance
with local state electrical codes.
Important! A licensed
electrician must connect
AC power source to
power cord leading into
termination enclosure.
4-5/8" (118 mm)
2"
(52 mm)
1-3/8"
(35 mm)
1/64"
(0.5 mm)
Male
Receptical
AC Input
(IEC 320
Inlet)
Symmons p/n, SF-01448
12VDC
Output
4 foot DC power cord
6 foot
AC power
cord
Dimensions
Power Supply, S-6240-12V
Installation Instructions, S-6095-AC-12V and S-6098-AC-12V
Multi-Faucet Installation
Reference Visual Guide illustration on page 3.
Step 1 Install Faucets
■ Install each sensor faucet per installation instructions
on page 2.
■ e maximum number of faucets DC power supply
can support is (8) eight.
■ A 10 foot (20 foot optional) extended DC power
cable is supplied with each faucet.
Step 2 Mount Termination Box
■ Mount box to a wall, under a
sink or closet location.
■ Ensure the furthest faucet is
located within 19 feet (5.8
meters) of the termination
enclosure.
Step 3 Run faucet’s extended DC power cable
■ Plug extended DC power cable plug into each faucet’s
power receptacle.
■ Run each extended power cable from faucet under
the sink to the termination box. Feed cable through
a strain relief and punched-out hole into the
termination box.
Avoid contact with water pipes and secure
cable in accordance with state and local
electrical codes.
Step 6 Connect AC Power
■ Connect 120/240 VAC power source to wire ends of
AC power cord. Note: A licensed electrician must
connect AC power source to power cord.
■ Plug AC power cord into power supply.
Faucets may all activate for one cycle on initial power up.
Step 4 Prepare power cable wire ends
■ Faucet extended DC power cables
Strip o a few inches of cable jacket and then strip
each wire to expose copper ends.
■ Power supply DC power cable
Strip o a few inches of cable jacket and then strip
ends of each wire to expose copper ends.
Step 5 Connect DC power wires
■ +12 VDC line - Connect each of the faucet’s
+LINE #1 black wires to the power cables red wire.
■ -RET (GND) line - Connect each of the faucet’s
- LINE #2 black wires to the power cables black wire.
■ Wire nuts - Secure wire connections using two wire
nuts with size that can join (8) AWG#20 wires and (1)
AWG#16 wire.
DimensionsEnclosure Box, S-6244
Symmons p/n, SF-194
10"
(254 mm)
6" (152 mm)
Note: Dimensions subject to change without notice.
Page 4
4"
(102 mm)
120 VAC
power
2.5 mm wrench
(included)
wrench
(included)
1
5
2
4
3
Service
Replace Solenoid Valve
Replace sensor
Cleaning water supply strainer
COLD
™
5-210 water
120 VAC
HOT
Symmons MAXLINE
temperature limiting valve shown for
illustration only and is not required
Troubleshooting
No water flow
■ Faucet is not receiving power from AC outlet. In multifaucet installations, faucet is not receiving power.
■ Filter in strainer is clogged. Excessive clogged lter
may require installing of separate ecient lter into
supply line.
■ Solenoid valve connector inside faucet is loose.
■ Circuit board is faulty. Do not attempt repair, please
2
contact Symmons customer service.
■ Solenoid valve is faulty. Do not attempt repair, please
contact Symmons customer service.
1
120 VAC
power
3
5
4
6
Faucet care
Cleaning surface finish
■ Block sensor with sensor cu to
prevent faucet from turning on
while cleaning.
■ Clean nish area by using
mild soap and water or nonabrasive cleaner and then rinse
immediately. A non-abrasive
wax may be used to preserve
nish area.
Precautions
■ Ensure sensor is not damaged through impact or
scratches.
■ Ensure sensor is not blocked or disturbed by any
objects.
■ Ensure a strong light source is not aimed directly at
sensor or through a mirror.
Center hole size
1-5/16" (34 mm) min
1-3/8" (37 mm) max
hose length
14-9/16"
(370 mm)
strainer / adapter
Note: Dimensions subject to change without notice.
3/8" compression
Parts Assembly Ultra-Sense Lavatory Faucet, S-6095-AC/ACM-12V, S-6098-AC/ACM-12V
S-6095-AC/ACM-12V, p/n SF-01399......5¼" Spout
S-6098-AC/ACM-12V, p/n SF-01400......8" Spout
aerator
1.5 gpm
removal key
spout, swivel or
xed forward
position
2.5 mm wrench
(included)
spout removal
screw
faucet body
2.5 mm wrench
(included)
snap on-off
sensor
protector
body fastener
screw
o-ring
sensor
sensor holder
removal tool
solenoid valve
120 VAC
transformer
wall plug
valve body
p/n SF-236
u-washer
hex nut
S-6095 / S-6098 Replacement Parts
Part Number Item
SF-240
SF-01531
SF-01532
SSF-108
SF-01657
SF-01535
FLR-130-1.5-KIT
FLR-01526
FLR-01524
Ordering replacement parts:
Call Symmons customer service at (800) 796-6667,
(781) 848-2250 M-F 7:30 am - 7:00 pm EST
or check our website at www.symmons.com for a
list of Symmons distributors.
Solenoid valve
with removal tool
Sensor
Sensor holder
Check / strainer kit
for ex hose
connections
Single hole
mounting kit
Spout rotation limit pins
and 60˚ limiter
Aerator, vandal resistant, with