Symmons S-6060 Service Manual

Ultra-Sense
Lavatory Faucet S-6060
Battery Powered, Sensor-Activated
Installation, Operation & Service Instructions
Model Numbers
■ S-6060.......Sensor Faucet
S-6060-G...Sensor Faucet with
grid strainer drain assembly
Tools & Materials
Need Help?
Symmons customer service: (800) 796-6667, (781) 848-2250 Email: customerservice@symmons.com Monday - Friday 8:00 am - 7:00 pm EST
www.symmons.com/service
■ Technical help
■ Product information
3 mm (included)
■ Warranty policy
Quick Install Guide Ultra-Sense Lavatory Faucet, S-6060
Part Number SF-231
Single hole mount
nished deck
front view
Step 1
Attach faucet to deck
Step 2
supply lines
Operation
Three hole mount
Step 1
Attach faucet to deck
with deck plate
Step 2
supply lines
supply
input
nished deck
front view
supply
input
Faucet Part Number SF-231
Installation Instructions
Important! Prior to connecting the water supply, ensure
supply lines are ushed. Particles can clog lter and result in malfunction. Excessive particles from supply lines may require installing a separate ecient lter.
Step 1 Attach faucet to deck (1 hole)
Single hole mount without deck plate
nished deck
front view
Step 2 Connect water supply line
19 mm
OFF
Step 3 Test operation and check for leaks
Step 1 Attach faucet to deck (3 hole)
Three hole mount with deck plate
nished deck
front view
Operation
Sensor range is preset, 1/2 - 4 inches
Place hand under faucet, water will ow automatically for 10 seconds and shut o.
Auto shut-off, 1/2 to 1 second
Remove hands, water will stop automatically within 1/2 to 1 second.
Security OFF after 10 seconds
Faucet will automatically shut o aer continuous water ow for 10 seconds.
Weak or dead battery
LED will ash to signal battery is getting weak and should be replaced soon.
Page 2Page 2
OFF
2
1
3
4
6
5
solenoid
3 mm
8 mm
Service Instructions
Battery replacement
3 mm
OFF
Cleaning water supply strainer
6 volt Lithium battery
Solenoid valve replacement
Sensor replacement
2
sensor
5
6
3
4
OFF
Troubleshooting
No water flow
■ No battery installed, battery connection is loose or battery power is low.
■ Filter in strainer is clogged. Excessive clogged lter may require installing of separate ecient lter into supply line.
■ Solenoid valve connector inside faucet is loose.
■ Circuit board is faulty. Do not attempt repair, please contact Symmons customer service.
■ Solenoid valve is faulty. Do not attempt repair, please contact Symmons customer service.
7
1
8
OFF
Faucet care
Cleaning surface finish
■ Block sensor to prevent faucet from turning on while cleaning.
■ Clean nish area by using mild soap and water or non­abrasive cleaner and then rinse immediately. A non­abrasive wax may be used to preserve nish area.
Precautions
■ Ensure sensor is not damaged through impact or scratches.
■ Ensure sensor is not blocked or disturbed by any object with its detection range.
■ Ensure that no strong light source is aimed directly at sensor or through a mirror.
Page 3Page 3
Dimensions Ultra-Sense Lavatory Faucet, S-6060, S-6060-AC/ACM
Part Number SF-231
2-3/8"
(60 mm)
2-1/8"
(54 mm)
nished deck thickness
1-3/16" (30 mm) max
5-1/4"
(105 mm)
5-1/8"
(130 mm)
3-5/8"
(92 mm)
28º
center hole size
1-5/16" (34 mm) min
1-7/16" (37 mm) max
Note: Dimensions subject to change without notice
ex hose length
20-1/4" (515 mm)
strainer / adapter
3/8" compression
Parts Assembly Ultra-Sense Lavatory Faucet, S-6060
Part Number SF-231
S-6060 Replacement Parts
lid
gasket
battery pack
sensor mounting
brackets
sensor
socket retainer
solenoid
faucet body
aerator and
removal tool
top lid bolt
3 mm Allen wrench
(included)
deck plate
gasket
anchor bar
spacer
hex nut
anchor bolt
screw
ex hose
strainer/adapter
6 volt Lithium battery
8 mm socket wrench
(not included)
Model: S-6060-SM
single hole mount
Part Number Item
SF-249
SF-2CR5
SF-240
SF-246
SSF-108 SF-181
SF-158
Ordering replacement parts:
Call Symmons customer service at (800) 796-6667, (781) 848-2250 M-F 7:30 am - 7:00 pm EST or check our website at www.symmons.com for a list of Symmons distributors.
3-3/8"
(85 mm)
Battery box for 6v lithium battery
6v Lithium battery, 2CR5
Solenoid kit with membrane
Sensor kit with mounting brackets
Check / strainer kit
for ex hose
for copper tubing
(option -LST)
Single hole mounting kit
housing
check
screen
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 ©2011 Symmons Industries, Inc. Printed in U.S.A.
(800)796-6667, (781)848-2250 Fax: (800)961-9621, (781)664-1300 www.symmons.com customerservice@symmons.com
Model# S-6060 Part# SF-231 Document #ZV-783 RevDate 083011
Loading...