How the SureShot Liquid Cooler Works
The liquid to be cooled (a total of 3.6L) is poured into the upper tank which begins the automated cooling process. Upon sensing the presence of the hot liquid, the unit automatically activates a solenoid to allow the cooling water to circulate through the heat exchanger. The cooling cycle is activated for approximately 100 seconds during which the product flows through the cooling unit to the lower tank. As the unit is based on the use of a heat exchanger, the cooling performance of the unit is largely dependant on the cold water temperature. The relationship between the cold water temperature and the resultant product temperature is indicated in the chart shown below.
LIQUID COOLER
PRODUCT IN @ 195F
Final Product Temperature will fall between two red lines
95
90
URE (F) T
85
PERA M
GENERAL REQUIREMENTS
• Requires a cold water supply line with a minimum
of 1.5 gallons (6 liters) per minute.
• Water pressure should be between 25 - 75 psi.
• Requires access to free drain.
• Water Inlet - 0.25
• Water Outlet - 3/8
GENERAL SPECIFICATIONS - NORTH AMERICA (MODEL AC-LC1)
Capacity: Upper Tank = 3.6 L Lower Tank = 9.0 L A/C Supply Voltage: 120v AC, 60 Hz, 0.5 amp, 1 ph Dimensions (LxWxH): 20" x 9" x 24" Weight: 30 lbs (empty)
" male 45° flare fitting.
" OD / 1/4" ID.
80
ODUCT TE PR
L NA
75
FI
70
SUPPLY WATER TEMPERATURE (F)
0756065505
KEY FEATURES
• Non-drip dispense faucet.
• Stainless steel nickel brazed heat exchanger.
• Unit “power on” and “in use” indication light.
• Cooled product level indication.
• Easily removable cooled product tank.
• Standard warranty is one year, on-site parts & labor.
• USA and Canada-wide Technical Service Network with
SureShot Technical Assistance Center support.
PD: Jan 2011
A.C. Dispensing Equipment Inc. 100 Dispensing Way Lower Sackville, NS B4C 4H2 Canada