suprema XPASS User Manual

Page 1
Page 2
Safety Precautions
Product Com
p
Contents
3 5
p
Optional Accessories Product Description
Product Dimension
6 7 10
Cabl
es and Connectors
Power Connection
LAN Connection
11 14 16
RS485
Connection
Relay Connection Digital Input Connection
Wiegand Input/Output
18
20 23 25
Output
Installation of Wall-mount Bracket
Installation Reference
26 27 28
S
pec
ificati
on
Electrical Specification
FCC Rules
31 32 33
-2-
Page 3
Do not install the device in a
Do not place the device next
Safety Precautions
place subject to direct sun
light, humidity, dust or soot.
to heating equipments.
Do not place a magnet near the product.
When cleaning, do not splash water on the device but wipe it out with a smooth cloth or towel.
It may cause a damage or a failure to the product.
Be careful not to let liquids like water, drinks or chemicals leak inside the device.
Clean the device often to remove dust on it.
The list below is to keep user’s safety and prevent any loss. Please read safety
It may cause a failure
.
-3-
precautions carefully before use
.
Page 4
Do not drop the device. Do not disassemble, repair or
Safety Precautions
alter the device
.
The warranty does net apply to any product damage cause by an arbitrary installation or repair.
Do not let children touch the device without supervision.
Do not use the device for any other purpose than specified.
Do not damage the device. Contact your nearest dealer in
case of a trouble or problem.
The list above is to keep user’s safety and prevent any loss. Please read safety
-4-
precautions carefully before use
.
Page 5
Product
Components
Basic Components
X
pass
B
racke
t
Extended Ethernet Cable
Wall M
ounting Screws
(2 ea)
Knife Block
s
(2 ea)
Shrinkable Tub
es
Soft
ware
CD
The components shown above may differ depending on the installation environment.
-5-
Page 6
Optional Accessories
Plastic standSecure I/O Extended Bracket Adaptor
-6-
Page 7
Product Description
-7-
Page 8
LED status
-8-
Page 9
Initialization of network setting
When you install the Xpass or forget the network setting’s value of Xpass in use, can initial the network
-
settings value (TCP/IP address, RS
485 setting) in the switch of Xpasss back side as follows;
-9-
Page 10
Product Dimension
(unit : mm)
< Extended Bracket >< Front View > < Bracket >< Side View >
-10-
Page 11
Cables and Connectors
No Pin Name Full Name Color
1 485 GND 485 GND White (black string) 2 WGD GND Wiegand-GND Black 3 485 - 485 - Yellow (black string) 4 WGD D1 Wiegand-1 White 5 485 + 485 + Blue (white string) 6 WGD D0 Wiegand-0 Green 7 IN 1 Input-1 Brown
8
RLY N
O
Relay Open
G
ray (white string
)
9 IN GND Input-GND Gray 10 RLY COM Relay Com Green (white string) 11 IN 0 Input-0 Purple
12
RLY NC
Relay Close
Orange (black string)
13 TX+ TX+ (LAN) Pink 14 PWR IN+ Power IN+ Red 15 TX- TX- (LAN) Orange
-
-
16
PWR IN
Power IN
Black (white string)
17 RX+ RX+ (LAN) Blue 18 PWR OUT+ Power OUT+ Light Blue 19 RX- RX- (LAN) Yellow 20 PWR OUT- Power OUT- Black (white string) 21 VB1 VB1 Green (black string) 22 VB2 VB2 Brown (white string) 23 VB1 VB1 Green (black string) 24 VB2 VB2 Brown (white string)
-11-
Page 12
Cables and Connectors
Cable Specification
Cable Pin Name Colo
r
1
Relay
RLY NC Orange (black string) 2 RLY COM Green (white string) 3 RLY NO Gray (white string) 4 WGD D0 Green
Wiegand
5WGD D1White 6 WGD GND Black 7
Switch
IN 0 Purple 8 IN 1 Brown 9IN GNDGray
10
485
485+ Blue (white string) 11 485- Yellow (black string) 12 485 GND White (black string)
Adaptor Connector Pin Name Color
POWER OUT - Black
(
white strin
g)
Power
(g)
POWER OUT + Light Blue 3 POWER IN - Black (white string) 1 POWER IN + Red
-12-
Page 13
LAN Connector Pin Name Color
1 RX- Yellow
LAN cable
LAN
2 RX+ Blue 3TX-Orange 4 TX+ Pink 5 VB1 Green (black string)
6
VB1
Green (black string)
7 VB2 Brown (white string) 8 VB2 Brown (white string)
Ethernet extension cable
Modular Jack (A) Connector (B) Pin Name Color
14TX+Blue 23TX-Oran
g
e
g
32RX+Black 6 1 RX- Yellow 4 5 VB1 Red 5 6 VB1 Green 7 7 VB2 Brown 8 8 VB2 Gray
-13-
Page 14
Power Connection
1
Pin Pin Name Color
14 PWR IN+ Red 16 PWR IN- Black (white string)
Recommended power supply
12V ± 10%, at least 1500mA. Comply with standard IEC/EN 60950-1. To share the power with other devices, use a power supply with higher current ratings.
-14-
Page 15
Power Connection
2
Please read below carefully before you install this product. This is essential steps for stable operation. Please
make sure to turn on the power of PSE only after connect all cables related to PoE
Connect 8port Ethernet connect of Xpass body to Ethernet expansion cable in right direction
Connect RJ45 modular from Ethernet expansion cable to Ethernet cable with CAT-5
Connect the opposite side of
Ethernet cable to PoE HUB port Connect cable from PC to port from
PoE HUB and connect the opposite side of cable to Ethernet port of PC
Connect power of PoE HUB
Please use the distance of LAN cable within 100m in case of PoE power.
Recommended Power Supply
PoE(Power over Ethernet
)
-15-
()
: Use PSE(Power sourcing Equipment) that complies with IEEE802.3af standard only.
Page 16
LAN Connection
-16-
Page 17
LAN Connection (Direct connection with PC)
-17-
Page 18
RS485 Connection for Host Communication
Pin Pin Name Color
1
485 GND
Whi
te
(black
string
)
3 485 - Yellow (black string) 5 485 + Blue (white string)
1
5 3
-18-
Page 19
RS485 Connection for Secure I/O
Pin Pin Name Color
1
485 GND
White (black string)
3 485 - Yellow (black string) 5 485 + Blue (white string)
Max number of devices
Maximum eight(8) devices (including Master) interworks in an RS485 loop.
-19-
Page 20
Relay Connection
Fail safe lock
PinPin N
ame
Color
10 RLY COM Green (white string) 12 RLY NC Orange (black string)
-20-
Page 21
Relay Connection
Fail secure lock
Pin Pin Name Color
8 RLY NO Gray (white string)
10 RLY COM Green (white string)
-21-
Page 22
Relay Connection
-
Automatic door
Pin Pin Name Color
8 RLY NO Gray (white string)
10 RLY COM Green (white string)
-22-
Page 23
Digital Input Connection (Alarm, Emergency S/W)
Pin
Pin Name
Color
7 IN 1 Brown 9IN GND Gray
11 IN 0 Purple
-23-
Page 24
Digital Input Connection (RTE, Door sensor)
Pin
Pin Name
Color
7 IN 1 Brown 9IN GND Gray
11 IN 0 Purple
Request to
q
Exit
-24-
Page 25
Wiegand Input
Wiegand Input/Output
Pin Pin Name Color
2 WGD GND Black 4WGD D1 White 6 WGD D0 Green
Wiegand Output
Pin Pin Name Color
2 WGD GND Black 4WGD D1 White 6 WGD D0 Green
-25-
Page 26
Output
Pin Pin Name Color
10 RLY COM Green (white string) 12 RLY NC Orange (black string) 18 PWR OUT + Light Blue 20 PWR OUT - Black (white string)
Caution : Max. 700mA is supplied using adapter for the external output.
-26-
Be careful to satisfy the power capacity in use
.
Page 27
Fix wall mount bracket on a wall using wall mounting screws
Hook Xpass on the wall mount bracket
Installation of Wall
-
mount Bracket
Fix Xpass and wall mounting bracket using
a wall mounting screw.
-27-
Page 28
Installation Reference 1
-
Stand alone
-28-
Page 29
Installation Reference 2
Standalone (
Secure
)
-29-
Page 30
Installation Reference 3
Network
-30-
Page 31
Specification
CPU 32 bit Micro-processor
Memory 8MB FLASH + 16MB SDRAM
RF Card
13.56 MHz Mif
are
(XPM)
125 KHz EM Prox (XPE) 125 KHz HID Prox (XPH)
User Capacity 40000 user
Lo
g
Capacit
y
50000 lo
g
gp y
g
Network interfaces TCP/IP, RS485
IP Rate IP 65 class
Sound Multi-tone buzzer
LED
Multi-color LED
RTC Lithium-ion rechargeable batteries
I/O
Relay x 1 Tamper x 1 Switch input x 2
Wiegand x 1
Power 12Vdc, POE
Operating Temperature
-20 ~ 50°C
Size 45 x 130 x 27mm
(
W x H x D )
()
Certificates CE, FCC, KCC, IP65
Caution for RTC Battery
-31-
It may be occurred the risk of
explosion
for improper replacement of battery
.
Please use the specified battery according to proper instruction.
Page 32
Min. Typ. Max. Notes
Power
Electrical Specification
Voltage (V) 10.8 13.2 Use regulated DC power adaptor only
Current (mA) - 182
Switch Input
V
IH (V) - TBD -
VIL (V) - TBD
Pull-up resistance () - 4.7k - The input ports are pulled up with 4.7k resistors
TTL/Wie
g
and Output
gp
VOH (V) - 5 -
VOL (V) - 0.8 -
Pull-u
p
resistance (Ω
)
-4.7k -
The outputs ports are open drain type, pulled up with 4.7k
p()
resistors internally
Relay
Switching capacity (A) - -
1
0.3
30V DC 125V AC
Switching power (resistive)
--
30W
37.5V A
DC AC
Switching voltage (V) - -
110 125
DC
A
C
-32-
Page 33
Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the
Caution
FCC Rules
equipment
.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interface, and (2) this device must accept any interface received, including interference that
Warning
may cause undesired operation.
This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
Information to User
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, user and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation
;
if this equipment does cause harmful interference to radio or
;qp
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more the following measures:
1. Reorient / Relocate the receiving antenna
.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help
-33-
Page 34