Safety Precautions
Product Com
Optional Accessories
Product Description
Product Dimension
Power Connection
LAN Connection
Relay Connection
Digital Input Connection
Wiegand Input/Output
20
23
25
Output
Installation of Wall-mount Bracket
Installation Reference
on
Electrical Specification
FCC Rules
31
32
33
-2-

Do not install the device in a
Do not place the device next
place subject to direct sun
light, humidity, dust or soot.
Do not place a magnet
near the product.
When cleaning, do not splash
water on the device but wipe it
out with a smooth cloth or towel.
It may cause a damage or
a failure to the product.
Be careful not to let liquids like
water, drinks or chemicals leak
inside the device.
Clean the device often to
remove dust on it.
The list below is to keep user’s safety and prevent any loss. Please read safety
precautions carefully before use

Do not drop the device. Do not disassemble, repair or
.
The warranty does net apply to any
product damage cause by an
arbitrary installation or repair.
Do not let children touch the
device without supervision.
Do not use the device for
any other purpose than
specified.
Do not damage the device. Contact your nearest dealer in
case of a trouble or problem.
The list above is to keep user’s safety and prevent any loss. Please read safety
precautions carefully before use

The components shown above may differ depending on the installation environment.
-5-

Plastic standSecure I/O Extended Bracket Adaptor
-6-

Initialization of network setting
When you install the Xpass or forget the network setting’s value of Xpass in use, can initial the network
settings value (TCP/IP address, RS
485 setting) in the switch of Xpasss back side as follows;

(unit : mm)
< Extended Bracket >< Front View > < Bracket >< Side View >
-10-

No Pin Name Full Name Color
1 485 GND 485 GND White (black string)
2 WGD GND Wiegand-GND Black
3 485 - 485 - Yellow (black string)
4 WGD D1 Wiegand-1 White
5 485 + 485 + Blue (white string)
6 WGD D0 Wiegand-0 Green
7 IN 1 Input-1 Brown
9 IN GND Input-GND Gray
10 RLY COM Relay Com Green (white string)
11 IN 0 Input-0 Purple
13 TX+ TX+ (LAN) Pink
14 PWR IN+ Power IN+ Red
15 TX- TX- (LAN) Orange
17 RX+ RX+ (LAN) Blue
18 PWR OUT+ Power OUT+ Light Blue
19 RX- RX- (LAN) Yellow
20 PWR OUT- Power OUT- Black (white string)
21 VB1 VB1 Green (black string)
22 VB2 VB2 Brown (white string)
23 VB1 VB1 Green (black string)
24 VB2 VB2 Brown (white string)
-11-

Cable Specification
Cable Pin Name Colo
1
Relay
RLY NC Orange (black string)
2 RLY COM Green (white string)
3 RLY NO Gray (white string)
4 WGD D0 Green
Wiegand
5WGD D1White
6 WGD GND Black
7
Switch
IN 0 Purple
8 IN 1 Brown
9IN GNDGray
10
485
485+ Blue (white string)
11 485- Yellow (black string)
12 485 GND White (black string)
Adaptor Connector Pin Name Color
POWER OUT - Black
POWER OUT + Light Blue
3 POWER IN - Black (white string)
1 POWER IN + Red
-12-

LAN Connector Pin Name Color
1 RX- Yellow
LAN cable
LAN
2 RX+ Blue
3TX-Orange
4 TX+ Pink
5 VB1 Green (black string)
7 VB2 Brown (white string)
8 VB2 Brown (white string)
Modular Jack (A) Connector (B) Pin Name Color
14TX+Blue
23TX-Oran
32RX+Black
6 1 RX- Yellow
4 5 VB1 Red
5 6 VB1 Green
7 7 VB2 Brown
8 8 VB2 Gray
-13-

Pin Pin Name Color
14 PWR IN+ Red
16 PWR IN- Black (white string)
Recommended power supply
12V ± 10%, at least 1500mA.
Comply with standard IEC/EN 60950-1.
To share the power with other devices, use a power supply with higher current ratings.
-14-

Please read below carefully before you install this product. This is essential steps for stable operation. Please
make sure to turn on the power of PSE only after connect all cables related to PoE
① Connect 8port Ethernet connect of
Xpass body to Ethernet expansion
cable in right direction
② Connect RJ45 modular from
Ethernet expansion cable to Ethernet
cable with CAT-5
Connect the opposite side of
Ethernet cable to PoE HUB port
④ Connect cable from PC to port from
PoE HUB and connect the opposite
side of cable to Ethernet port of PC
⑤ Connect power of PoE HUB
Please use the distance of LAN cable within 100m in case of PoE power.
Recommended Power Supply
PoE(Power over Ethernet
: Use PSE(Power sourcing Equipment) that complies with IEEE802.3af standard only.

LAN Connection (Direct connection with PC)

RS485 Connection for Host Communication
3 485 - Yellow (black string)
5 485 + Blue (white string)

RS485 Connection for Secure I/O
3 485 - Yellow (black string)
5 485 + Blue (white string)
Max number of devices
Maximum eight(8) devices (including Master) interworks in an RS485 loop.
-19-

10 RLY COM Green (white string)
12 RLY NC Orange (black string)
-20-

Pin Pin Name Color
8 RLY NO Gray (white string)
10 RLY COM Green (white string)
-21-

Pin Pin Name Color
8 RLY NO Gray (white string)
10 RLY COM Green (white string)
-22-

Digital Input Connection (Alarm, Emergency S/W)
7 IN 1 Brown
9IN GND Gray
11 IN 0 Purple
-23-

Digital Input Connection (RTE, Door sensor)
7 IN 1 Brown
9IN GND Gray
11 IN 0 Purple
Request to

Pin Pin Name Color
2 WGD GND Black
4WGD D1 White
6 WGD D0 Green
Wiegand Output
Pin Pin Name Color
2 WGD GND Black
4WGD D1 White
6 WGD D0 Green
-25-

Pin Pin Name Color
10 RLY COM Green (white string)
12 RLY NC Orange (black string)
18 PWR OUT + Light Blue
20 PWR OUT - Black (white string)
Caution : Max. 700mA is supplied using adapter for the external output.
Be careful to satisfy the power capacity in use

Fix wall mount bracket on a wall using
wall mounting screws
Hook Xpass on the wall mount bracket
Fix Xpass and wall mounting bracket using
a wall mounting screw.
-27-

CPU 32 bit Micro-processor
Memory 8MB FLASH + 16MB SDRAM
125 KHz EM Prox (XPE)
125 KHz HID Prox (XPH)
User Capacity 40000 user
Lo
Network interfaces TCP/IP, RS485
IP Rate IP 65 class
Sound Multi-tone buzzer
RTC Lithium-ion rechargeable batteries
I/O
Relay x 1
Tamper x 1
Switch input x 2
Wiegand x 1
Power 12Vdc, POE
Operating Temperature
-20 ~ 50°C
Size 45 x 130 x 27mm
Certificates CE, FCC, KCC, IP65
Caution for RTC Battery
-31-
It may be occurred the risk of
for improper replacement of battery
.
Please use the specified battery according to proper instruction.

Min. Typ. Max. Notes
Power
Voltage (V) 10.8 13.2 Use regulated DC power adaptor only
Current (mA) - 182
Switch Input
IH (V) - TBD -
VIL (V) - TBD
Pull-up resistance (Ω) - 4.7k - The input ports are pulled up with 4.7k resistors
TTL/Wie
VOH (V) - 5 -
VOL (V) - 0.8 -
Pull-u
-4.7k -
The outputs ports are open drain type, pulled up with 4.7k
Relay
Switching capacity (A) - -
1
0.3
30V DC
125V AC
Switching power
(resistive)
--
37.5V
A
DC
AC
Switching voltage (V) - -
110
125
DC

Changes or modifications not expressly approved by the manufacturer
responsible for compliance could void the user’s authority to operate the
.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interface, and
(2) this device must accept any interface received, including interference that
Warning
may cause undesired operation.
This equipment has been tested and found to comply with the limit of a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, user and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation
if this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more the
following measures:
1. Reorient / Relocate the receiving antenna
.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit difference from that to
which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help
-33-