suprema BioLite Solo User Manual

Page 1
EN 102.00.BLS V1.13
Page 2
2
This manual is provided for information purpose only. All information included herein is subject to change without notice. Suprema is not responsible for any changes, direct or indirect, arising from or related to us of this manual.
Copyright 2008 Supremainc. All rights reserved.
Page 3
3
Contents
Safety Instructions .................................................................................................... 4
1. Before Use ............................................................................................................. 5
1.1 Components .................................................................................................................. 5
1.2 Body .............................................................................................................................. 6
1.3 Methods for fingerprint input .......................................................................................... 7
1.4 System setup procedure ................................................................................................ 8
1.4.1 Registering the initial administrator .......................................................................... 9
1.4.2 Stand-alone configuration ................................................................ ...................... 10
1.4.3 Configuring Secure I/O .......................................................................................... 12
1.4.4 Configuring environment settings .......................................................................... 14
1.5 Authorization methods ................................................................................................. 14
2. User Management ................................................................................................ 16
2.1 Enrolling a user ........................................................................................................... 16
2.2 Editing a user data....................................................................................................... 18
2.3 Deleting a user data .................................................................................................... 21
3. Configuration for Screen and Sound ................................................................. 22
3.1 Date, Time ................................................................................................................... 22
3.2 Backlight...................................................................................................................... 23
3.3 Sound ................................................................ .......................................................... 23
4. Device Configuration .......................................................................................... 24
4.1 Authorization ............................................................................................................... 24
4.2 In/Out .......................................................................................................................... 26
4.3 System ................................ ................................................................ ........................ 30
5. FAQ ..................................................................................................................... 334
5.1 Error messages ......................................................................................................... 345
5.2 Troubleshooting ......................................................................................................... 356
5.3 Usage summary ........................................................................................................ 367
5.4 System Installation .................................................................................................... 378
5.4.1 Cable specifications ............................................................................................. 378
5.4.2 Connecting Power & 485 ..................................................................................... 389
5.4.3 Connecting the relay ............................................................................................. 40
5.4.4 Connecting the switch ......................................................................................... 411
5.4.5 Electrical specifications ....................................................................................... 411
5.4.6 Installing the bracket ........................................................................................... 422
5.5 Specifications ............................................................................................................ 433
Page 4
4
Safety Instructions
Installation
In Use
Do not arbitrarily install or repair the product.
The warranty does not apply to any product damage caused by an arbitrary installation or repair.
Endure that password does not exposed to unauthorized individuals. Frequent change of password is recommended.
Any illegal access to
your product may happen.
Do not operate the product with wet hands and keep the device away from any liquid contact.
It may cause a damage
or a failure to the product..
Do not forcibly press the buttons of the product and avoid any contact with sharp object to the device.
It may cause a failure.
Do not clean the device with any form of liquid. Use soft and dry cloth only.
Page 5
5
1. Before Use
1.1 Components
Main Body
Wall mounting bracket
Extended bracket
(Option)
Fixing Screws
(2 EA)
Knife Blocks
(2 EA)
Star-shape wrench
(For fixing bracket)
Adapter (Option)
Shrinkable Tubes
The components shown above may differ depending on the installation environment.
Diode
(1 EA)
Page 6
6
1.2 Body
No.
Name
Description
1
LCD Display
The operation status is displayed.
2
Key Pad
0–9 Buttons: Used to enter the ID and password. < > Arrow Buttons: Used to move the selected item.
Button: Used to select the desired function. Button: Used to enter the menu. Button: Used to exit from the menu or cancel the desired action.
3
LED Lamp
The operation status is displayed with an alert sound.
- Green (Sound: beep beep beep beep!): Authorization success
- Red (Sound: beep beep beep!) : Authorization failure
- Pink (Sound: beep!) : Processing
- Blue and Sky Blue blink in turn at an interval of 2 seconds (No sound): Normal operation
- Red and Pink blink in turn at an interval of 2 seconds (No sound): Device locked or no administrator
- Blue and Red blink in turn at an interval of 2 seconds (No sound): The time is reset due to battery discharge.
- Red blinks at an interval of 2 seconds (No sound): Device initialization failure. Please contact with the manufacturer.
- Yellow blinks shortly (No sound): Input ready status
4
Fingerprint Touch Area
Used to input a fingerprint for authentication.
Page 7
7
1.3 Methods for fingerprint input
BioLite Solo can easily recognize fingerprints even though the angle and location of the pattern change. However, it is recommended to properly input fingerprints for more precise recognition.
Selecting a finger on fingerprint enrollment
How to proerply place a fingerprint
Place your finger firmly on the sensor area. Adjust the finger so that its middle position can be located in the center of the sensor. When the finger is vertically placed or its angle goes astray, the recognition may be a failure.
Up to two fingerprints can be enrolled for each user in preparation of any abnormal situation like having a wounded finger or carrying an object with a hand. In the case of a low recognition, the user can register the same fingerprint twice to increase the recognition rate. It is recommended to use the index or middle finger. In case of other fingers, the recognition rate decreases because it tends to be more difficult to place the finger in the center of the sensor area.
Place the first
Finger
When enrolling your fingerprint, the first finger input window prompts. Then register the desired finger on the terminal as shown in the figure below. When the re-entry window appears with a tick sound, re-enter the previously enrolled finger. The fingerprint input is made twice. (Gently push your finger on the sensor to have a full fingerprint.)
Page 8
8
1.4 System setup procedure
Install the system according to the environment
- Grasp the locations for installation site, door open switch,
dead bolt, and such.
- Install the system (see 5.4).
Step 1
Register an initial administrator
- Register the initial administrator for setting devices (See 1.4.1).
Step 2
Configure the system
- Stand alone configuration (see 1.4.2.) or
- Secure I/O configuration (see 1.4.3)
Step 3
Test for system operation
- Check the door lock/unlock status and switch operation.
- Deliver the setting items to the customer.
Step 4
Configure the environment
- Configure various environments (see 1.4.4).
Step 5
Register users
- Use the system after user registration (see 2.1).
Step 6
Page 9
9
1.4.1 Registering the initial administrator
There is no administrator set for the product in the initial status. So register an administrator for configuring the environments for relay, door open switch, door open detection sensor, and such.
1. When the product is connected, a window
appears as shown in the right figure. Enter an ID and press OK.
2. When the authorization mode window appears,
use /◀ buttons to move to PIN Only, and press OK.
3. When the password entry window appears, enter
the desired password and press OK.
4. When the password re-entry window appears,
enter the previously input password again and press OK.
5. The completion message window appears.
Operation Mode
PIN Only
Enroll
Enter PIN
****
Enroll
Confirm PIN
****
Enroll
Completed
This procedure is necessary to temporarily configure the installation­related settings. Modify the administrator information after the installation is complete.
Enter ID 1
Enroll Admin
Page 10
10
1.4.2 Stand-alone configuration
This configuration is the most common installation method.
1. As shown in the figure, connect BioLite Solo to
respective switches.
See 5.4.6 Installing the bracket.
2. Configure the internal relay settings as shown below. (It is explained based on the
figure above.)
Use / buttons to select Internal and press OK.
Use / buttons to select Input 0 and press
OK.
Relay
Internal
Door
Exit Button
Input 0
Internal
Use / buttons to select N.O and press OK. *N.O/N.C
Type
N.O
Exit Button
Device
In/Out
Use / buttons to select the In/Out icon and press OK.
Press MENU -> Enter ID ­> Enter the password -> Use / buttons to select the Device icon and press OK.
Item
Door
In/Out
Use / buttons to select Door and press OK.
For actual wring method, see ”5.4 System Installation.
Cont.
Page 11
11
※ Opening Mode
- Temporary Open
: When the door is open, it is automatically closed after a specific time.
- Toggle: The door is open after the first authorization success and it remains unlocked until the second authorization success.
Enter the time and press OK.
*The time is set for automatically closing the door after the specified time.
Use / buttons to select Not Use for
Held
Open Alarm
and press OK.
*Not Use/Sound/ Backlight/Sound and Light/SIO Relay0/SIO Relay1
Door Sensor
Input 1
Internal
Held Open Alarm
Not Use
Door
Use / buttons to select N.O and press OK.
*N.O/N.C
Use / buttons to select Input 1 and press OK. *Not Use/Input0/Input1
Use / buttons to select Temporary Open for opening mode and press OK.
* Temporary Open/ Toggle
Opening Mode
Temporary Open
Door
Type
N.O
Door Sensor
Open Time
3
Door
Use / buttons to select Not Use for Forced Open Alarm and press OK.
*Not Use/Sound/ Backlight/Sound and Light/SIO Relay0/ SIO Relay1
The completion message window appears.
Forced Open Alarm
Not Use
Door
Complete
When you exit from the menu before completing the relay setup, the configuration is not stored so please finish configuration until the message Complete appears.
Page 12
12
Cont.
1.4.3 Configuring Secure I/O
This connects BioLite Solo to Secure I/O.
1. Connect wires between BioLite Solo, Secure I/O, and respective switches as shown
below.
See 5.4.6 Installing the bracket.
2. Configure the relay settings as shown below. (Based on the figure above)
Use / buttons to select SIO Relay 0 and press OK.
Use / buttons to select SIO Relay 0 and press OK.
(*Not Use/ SIO Input 0/ SIO Input 1)
Relay
SIO Relay 0
Door
Exit Button
SIO Input 0
SIO Relay 0
Use / buttons to select N.O and press OK.
Type
N.O
Exit Button
Device
In/Out
Use / buttons to select the In/Out icon and press OK.
Press Menu -> Enter ID -> Enter password ->Use/ buttons to select the
Device icon and press OK.
Item
Door
In/Out
Use / buttons to select Door and press OK.
For actual wiring, see 5.4 System Installation.
Sync button should be pressed after complete the relay setting.
Page 13
13
Opening Mode
-Temporary Open: When the door is open, it is automatically closed after a specific time.
-Toggle: The door is opened after the first authorization success and it remains unlocked
until the second authorization success.
Enter the time and press OK.
*The time is set for automatically closing the door after the specified time.
Use / buttons to select Not Use for Held Open Alarm and press OK.
*Not Use/Sound/Backlight/ Sound & Light/SIO Relay0/ SIO Relay1
Door Sensor
SIO Input 1
SIO Relay 0
Held Open Alarm
Not Use
Door
Use / buttons to select N.O and press OK.
Use / buttons to select SIO Input 1 and
press OK.
*Not Use/ SIO Input0/ SIO Input1
Opening Mode
Temporary Open
Door
Use / buttons to select Temporary Open for opening mode and press OK.
* Temporary Open/Toggle
Type
N.O
Door Sensor
Open Time(sec)
3
Door
Use / buttons to select Not Use for Forced Open Alarm and press OK.
*Not Use/Sound/Backlight/ Sound & Light/SIO Relay0/ SIO Relay1
The completion message window appears.
Forced Open Alarm
Not Use
Door
Complete
When you exit from the menu before completing the relay setup, the configuration is not stored so please finish configuration until the message “Complete” appears.
Sync button (In case of using Secure I/O)
Synchronization between Secure I/O and BioLite Solo is to enhance security by exchanging an encrypted key, which prevents the operation of Secure I/O when the external device has been exchanged by an intruder. Sync button should be pressed when Relay setting is completed.
Page 14
14
1.4.4 Configuring environment settings
Settings for date and time: Set the values as 3.1 Date, Time. Setting for authorization period: Set the value after reading the case of
authorization period selection in 4.1 Authorization,
Fingerprint authorization related settings: Set the values after reading the case of
fingerprint selection in 4.1 Authorization.
Setting for fingerprint sensor mode: Set the value after reading the case of
fingerprint sensor mode selection in 4.1 Authorization.
1.5 Authorization methods
Finger Only
Finger or PIN
Enter the ID of the user and press OK.
Enter the password of the user and press OK.
The door is open with the authentication success message.
Input the fingerprint of the user.
The door is open with the authentication success message.
Enter ID
2
Enter Finger or PIN
Access Granted
ID : 2
Access Granted
ID : 2
BioLite Solo
10:33:02
In case of the user registration by Finger or PIN, you can open the door by entering the fingerprint only.
Input the fingerprint of the user.
The door is open with the authentication success message.
Access Granted
ID : 2
BioLite Solo
10:33:02
Or
Page 15
15
Finger and PIN
PIN Only
Enter the ID of the user and press OK.
Input the fingerprint of the user.
Enter the password of the user and press OK.
The door is open with the authentication success message.
Enter ID
2
Enter Finger
Enter PIN
****
Access Granted
ID : 2
Enter ID
2
Enter the ID of the user and press OK.
Enter the password of the user and press OK.
The door is open with the authentication success message.
Enter PIN
Access Granted
ID : 2
Page 16
16
2. User Management
This chapter explains how to enroll, modify, and delete user data.
2.1 Enrolling a user
You can enroll a new user as shown below:
1. Use /◀ buttons to select the User ( ) icon
and press OK.
2. Use /◀ buttons to select Enroll ( ) icon and
press OK.
3. The ID that can be used appears. Use it or enter
another ID and press OK. (1–8 digit number)
4. Use /◀ buttons to select Level and press OK.
(Level: General /Administrator)
The user enrollment and environment configuration
are enabled only in Administrator level.
5. Use /◀ buttons to select Operation Mode.
(Finger Only /PIN Only/Finger or PIN/Finger and PIN)
Refer 1.5 Authorization methods.
User
Enroll
Enter ID
3
Enroll
Level
General
Enroll
Operation Mode
Finger Only
Enroll
ID is used to edit or delete the user data so please keep it carefully.
Page 17
17
6. Enter the finger or PIN depending on the operation mode.
(Password: 4–8 digit number, Fingerprint: 1st finger/1st + 2nd fingers)
Finger Only/Finger or PIN/Finger and PIN
In order to skip the second fingerprint enrollment after enrolling the first
fingerprint, press ESC.
The user can enroll one or two fingerprints for passing the door.
PIN Only/ Finger and PIN
For password, it is recommended to enter 4 to 8 digit number not to be easily
exposed.
7. When the user enrollment is successfully done,
the completion message window appears.
User can be enrolled up to maximum 200.
Completed
Confirm PIN
*****
Enroll
Place the first
finger again
Place the first
finger
Place the second
finger
(Skip=ESC)
Enter PIN
*****
Enroll
Place the first finger on the sensor.
Place the same finger on the sensor again.
Place the second finger in the same manner.
Page 18
18
2.2 Editing a user data
You can modify the data of the previously enrolled user.
1. Use /◀ buttons to select the User ( ) icon
and press OK.
2. Use /◀ buttons to select the Edit ( ) icon
and press OK.
3. Enter the ID or fingerprint of the desired user and
press OK.
4. Use ▶/ buttons to select the desired item and press OK .
Select any of Level, Operation Mode, Security Level, Fingerprint, PIN, and Access
Timezone.
Changing the user level
The user registration and environment configuration are enabled only in
Administrator level.
User
Item
Level
Edit
Use / buttons to select Level and press OK.
Use / buttons to select General or Administrator.
Press OK.
Edit
Enter ID/Finger
4
Edit
Level
General
Edit
Page 19
19
Changing the operation mode of the user
Operation: *PIN Only/Finger or Pin/Finger and PIN
/Finger Only
Changing the security level of the user
※ Security Level
: *Per Device/Lower/Low/
Normal
/High/Higher
-Per Device: The security in Device>Authorization>Fingerprint> on page 25 is applied.
-The higher the security level, the more sensitive the fingerprint recognition. But the authorization failure rate can increase.
Changing the fingerprint of the user
Item
Operation Mode
Edit
Use / buttons to select Operation Mode and press OK.
Use / buttons to select a operation mode and press OK.
Press OK.
Use / buttons to select Security Level and press OK.
Use / buttons to select a security level.
Place the first
finger again
Operation Mode
Finger Only
Edit
Item
Security Level
Edit
Security Level
Normal
Edit
Press OK.
Item
Fingerprint
Edit
Place the second
finger
(Skip=ESC)
Place the first
finger
Use / buttons to select Fingerprint and press OK.
Place the first finger on the sensor.
Place the same finger on the sensor again.
Enroll the second fingerprint in the same manner.
Page 20
20
Changing the PIN of the user
Changing the access timezone (authorization trial is enabled) of the user
※ Access Timezone
: *
Per Device /Always Allowed/Always Blocked/Per Weekday
- Per Device
: The access timezone set in 4.1 Authorization is applied.
[In case of selecting Per Weekday]
Select Weekday: You can select maximum of 5 timezone for each day.
Press OK.
Use / buttons to select Access Timezone and press OK.
Select the access time zone of the user.
Select Weekday
Sunday
Per Weekday
After selecting the timezone for each day as shown in the figure, enter values for Start Time and End Time.
Item
PIN
Edit
Use / buttons to select PIN and press OK.
Enter the desired password and press OK.
After re-entering the password of the user, press OK.
Enter PIN
****
Edit
Confirm PIN
****
Edit
Item
Access Timezone
Edit
Access Timezone
Per Device
Edit
Timezone
1
Sunday
Start Time(hhmm)
0000
1
End Time(hhmm)
1200
1
When you exit without setting the time after selecting Select Weekday only, the start time and end time are set to 00:00” and Timezone is set to “Always Blocked.
Page 21
21
2.3 Deleting a user data
You can delete unnecessary user data.
1. Use /◀ buttons to select the User ( ) icon
and press OK.
2. Use /◀ buttons to select the Delete ( ) icon
and press OK.
3. After entering the ID or finger to delete and press
OK.
4. When the action is successfully made, the
message Deletion appears.
The deleted user cannot be recovered.
If necessary, enroll it again.
User
Delete
Enter ID/Finger
4
Delete
Deletion
If all the users including the administrator are deleted, you must register the initial administrator again (see 1.4.1).
Page 22
22
3. Configuration for Screen and Sound
3.1 Date, Time
You need to set the current system date and time. Based on these settings, the values are correctly stored when you save data for Select Weekday or log data.
1. Use /◀ buttons to select the Screen, Sound
( ) icon and press OK.
2. Use /◀ buttons to select the Date, Time ( )
icon and press OK.
3. Enter the current date by following the suggested
format and press OK.
4. Enter the current time by following the suggested
format and press OK.
Screen, Sound
Date, Time
Date(YYYYMM00)
20080605
Date, Time
Time(hhmmss)
102055
Date, Time
Page 23
23
3.2 Backlight
1. Use /◀ buttons to select the Screen, Sound
( ) icon and press OK .
2. Use /◀ buttons to select Backlight ( ) icon
and press OK.
3. Use /◀ buttons to select a backlight operation status and press OK.
3.3 Sound
1. Use /◀ buttons to select the Screen, Sound
( ) icon and press OK.
2. Use /◀ buttons to select Sound ( ) icon
and press OK.
3. Use /◀ buttons to select the sound operation status and press OK.
Or
Screen, Sound
Or
Backlight
Mode
On at Use
Backlight
Mode
Always On
Backlight
Screen, Sound
Sound
Mode
On
Sound
Mode
Off
Sound
Page 24
4. Device Configuration
4.1 Authorization
1. Use /◀ buttons to select the Device ( ) icon
and press OK.
2. Use /◀ buttons to select the Authorization
( ) icon and press OK.
3. Use /◀ buttons to select any of
Access
Timezone
, Fingerprint, and Sensor Mode and
press OK.
In case of Access Timezone
[In case of Per Weekday]
See the description of [In case of selecting Per Weekday] on page 20.
Item
Access Timezone
Authorization
Press OK.
Use / buttons to select Access Timezone and press OK.
Select the desired access time zone.
* Always Allowed /Always Blocked/Per Weekday
Authorization
Item
Access Timezone
Authorization
Device
Type
Always Allowed
Access Timezone
When you exit without setting the time after selecting Select Weekday only, the start time and end time are set to 00:00” and Timezone is set to “Always Blocked.
The users can use the access time zone specified here. (See the description in Per Device on page 20.) In order to apply the setting directly to each user, select one of Always Allowed, Always Blocked or Per Weekday in user’s access Timezone setting. (refer page 20)
Page 25
In case of Fingerprint
Security Level: The higher the security level, the more sensitive the fingerprint recognition. But the
authorization failure rate can increase.
Image Quality
: It is the image quality level used when entering the fingerprint data.
In case of Low, the fingerprint can be easily input but the correct authorization is
not guaranteed.
Sensitivity
: The higher the value, the more sensitive the sensor.
Check Duplicate:
When enrolling a user, it determines whether or not to check the fingerprint
data is already enrolled.
Item
Fingerprint
Authorization
Use / buttons to select Fingerprint and press OK.
Use / buttons to select Security Level and
press OK.
Use / buttons to select Security Level and press OK.
* Normal /Secure/More Secure
Use / buttons to select Image Quality and press OK.
Use / buttons to select Image Quality and press OK.
*Normal/High/Low
Use / buttons to select Sensitivity and press OK.
Use / buttons to select Sensitivity level and press OK.
*0~7
Use / buttons to select Check Duplicate and press OK.
Use / buttons Check Duplicate and press OK.
* Not Use /Use
Item
Security Level
Fingerprint
Security Level
Normal
Fingerprint
Item
Image Quality
Fingerprint
Image Quality
Normal
Fingerprint
Item
Sensitivity
Fingerprint
Sensitivity
7
Fingerprint
Item
Check Duplicate
Fingerprint
Check Duplicate
Not Use
Fingerprint
Page 26
In case of
Sensor Mode (operates the fingerprint sensor)
Sensor Mode
: *
Always On
/ID Entered/OK Pressed
- Always On: The sensor always waits for a fingerprint input.
-ID Entered/OK Pressed: It requires entry of ID or OK before a fingerprint input.
4.2 In/Out
1. Use /◀ buttons to select the Device ( ) icon
and press OK.
2. Use /◀ buttons to select In/Out ( ) icon and
press OK.
3. Use /◀ buttons to select any of Serial Conn.,
Tamper On, and Door and press OK.
In case of Serial Conn.
※ Serial Conn. Speed : Not Use/9600/19200/36400/57600/*115200
-It is used only when the log data is retrieved after connecting the PC.
Press OK.
Use / buttons to select Sensor Mode and press OK.
Use / buttons to select a sensor mode.
Item
Sensor Mode
Authorization
Press OK.
Use / buttons to select Serial Conn.
And
press
OK.
Use / buttons to select the data speed.
Item
Serial Conn.
In/Out
Device
On Condition
Always On
Sensor Mode
In/Out
Item
Serial Conn.
In/Out
Serial Conn.
Not Use
In/Out
Page 27
Cont.
In case of Tamper On
※ Tamper
: *
Ignore
/Locked
-Locked: When the device is forcibly removed, the Device is locked.
(To release the lock, the administrator must perform authorization.)
In case of Door (When using the internal relay)
Opening Mode: When a specific time elapses after the door is open, the door is
automatically closed.
Item
Tamper On
In/Out
Item
Door
In/Out
Press OK.
Use / buttons to select Tamper On and press
OK.
Use / buttons to select a tamper method.
Use / buttons to select Door.
Use / buttons to select Internal.
Use / buttons to select Exit Button.
* Not Use/ Input 0/ Input 1
Tamper
Ignore
In/Out
Relay
Internal
Door
Exit Button
Input 0
Internal
Use / buttons to select the type for
Exit
Button
.
*N.O/N.C
Type
N.O
Exit Button
Door Sensor
Input 1
Internal
Use / buttons to select a
door sensor type.
*N.O/N.C
Use / buttons to select Door Sensor.
*Not Use/Input
Opening Mode
Temporary Open
Door
Use / buttons to select a opening mode.
*Temporary Open/ Toggle
Type
N.O
Door Sensor
Enter the time and press OK.
Use / buttons to select the type for Held Open Alarm.
* Not Use /Sound/Backlight/ Sound& Light/SIO Relay0/ SIO Relay1
Held Open Alarm
Not Use
Door
Open Time(sec)
3
Door
Page 28
Cont.
※ Opening Mode
- Temporary Open: When the door is open, it is automatically closed after a specific time.
- Toggle: The door is opened after the first authorization success and it remains unlocked
until the second authorization success.
In case of Door (When using the SIO relay)
Use / buttons to select the relay type.
Use / buttons to select the exit button.
* Not Use/SIO Input0/ SIO Input1
Relay
SIO Relay0
Door
Exit Button
SIO Input0
SIO Relay0
Item
Door
In/Out
Use / buttons to select Door.
Use / buttons to select the type of the exit button.
*N.O/N.C
Type
N.O
Exit Button
Enter the held open time by using the Numeric buttons and press OK.
Forced Open Alarm
Not Use
Door
Completed
Use / buttons to select the type for Forced Open Alarm.
*Not Use/Sound/ Backlight/Sound and Light/SIO Relay0/ SIO Relay1
The completion message window appears.
When you exit from the menu before completing the relay setup, the configuration is not stored so please finish configuration until the message “Complete” appears.
Door Sensor
SIO Input1
SIO Relay0
Use / buttons to select the door sensor type.
*N.O/N.C
Use / buttons to select the door sensor.
*Not Use/ SIO Input1
Type
N.O
Door Sensor
Held Open Time(sec)
30
Door
Page 29
Opening Mode: When a specific time elapses after the door is open, the door is
automatically closed.
Opening Mode
- Temporary Open
: When the door is open, it is automatically closed after a specific time.
- Toggle: The door is opened after the first authorization success and it remains unlocked until the second authorization success.
Enter the time and press OK.
Use / buttons to select the alarm type.
*Not Use/Sound/Backlight/ Sound and Light/SIO Relay0/SIO Relay1
Held Open Alarm
Sound
Door
Enter the time for Held Open Alarm by using the Numeric buttons and press OK.
Held Open Alarm(sec)
30
Door
Opening Mode
Temporary Open
Door
Use / buttons to select the type of the opening mode.
*Temporary Open/ Toggle
Open Time(sec)
3
Door
Use / buttons to select the type for Forced Open Alarm.
*Not Use/Sound/ Backlight/Sound and Light/SIO Relay0/ SIO Relay1
The completion message window appears.
Forced Open Alarm
Not Use
Door
Complete
Page 30
4.3 System
1. Use /◀ buttons to select the Device ( ) icon
and press OK.
2. Use ▶/◀ buttons to select the System ( )
icon and press OK.
3. Use ▶/◀ buttons to select any of Information,
Factory Default, Delete All Log, Delete User DB, and Language and press OK.
In case of Information
Item
Log
Information
Use / buttons to select Log.
Use / buttons to select Not Use.
Device
System
Item
Information
System
Filter
Not Use
Log User
All
Filter
Use / buttons to select any of All and Select ID.
Use / buttons to select any of All and Specify Date
.
The log filtering result appears on the screen. (Use / buttons to see the previous/next logs.)
6/18 14:20(3)
Delete OK
6/18 13:46(3)
Enroll OK
The entire logs appear. (Use / buttons to see the previous/next logs.)
6/18 16:21(1)
Set Time
6/18 14:20(3)
Delete OK
Filter
-
Not Use
: Displays all.
-
Use
: Only the specified log is
displayed.(ID/Date/Event Type)
When the date is specified, the
logs occurred earlier than the specified date.
When Use is selected
Event
All
Filter
Use / buttons to select the event type.
*All/Success/Failure/In/Out/ System
Date
All
Filter
Page 31
In case of Information Continued
In case of Factory Default
In case of Initialize, the settings are deleted but the log data and user DB are
not deleted.
Item
Factory Default
System
Use / buttons to select Num. Of User.
The number of current users and the number of fingerprints enrolled appear.
The version of the firmware appears.
Use / buttons to select Factory Default and press OK.
Use / buttons to determine whether or not to initialize it.
*Cancel/ Initialize
Item
Num. Of User
Information
Item
Firmware Ver.
Information
User
Templates
6/800
4/200
Firmware Ver.
V0.9_080603
Information
Initialize?
Initialize
Factory Default
In case of Initialize, the message Initialized appears.
Initialized
Use / buttons to select Firmware Ver
.
The version of the hardware appears.
Item
Hardware Ver.
Information
Hardware Ver.
1024(Rev.C)
Information
Use / buttons to select Hardware Ver.
Page 32
In case of Delete All Log
In this case, all users in/out data are deleted and they cannot be recovered.
In case of Delete User DB
In this case, the users DB is completely deleted so you must immediately
register the initial administrator (see 1.4.1).
When the user DB is deleted, it cannot be recovered.
In case of Language
To use custom language, desired language resource file needs to be downloaded
to t he device using AdminLite program on PC. Please contact Suprema for details.
Item
Delete User DB
System
In case of Delete, the message Deletion appears.
Use / buttons to select Delete All Log and press OK.
Use / buttons to determine whether or not to delete them.
*Cancel/ Delete
In case of Delete, the message Deletion appears.
Use / buttons to select Delete User DB and press OK.
Use / buttons to determine whether or not to delete the user DB.
*Cancel/Delete
Use / buttons to select Language and press OK.
Use / buttons to select the language.
* English/ Korean/Custom
Press OK.
Item
Delete All Log
System
Delete?
Delete
Delete All Log
Deletion
Delete?
Delete
Delete User DB
Deletion
Item
Language
System
Item
English
Language
Page 33
In case of Contrast
Contrast value is not affected by Factory default.
Use / buttons to select Contrast and press OK.
Use / buttons to adjust contrast parameter.
* Default value is 18
Press OK.
Item
Contrast
System
Item
18
System
Page 34
5. FAQ
5.1 Error messages
Error Message
Solution
!Unknown ID
The user ID that does not exist in the device is entered.
!Not Matched
The entered fingerprint or password is not matched to the enrolled one.
!Duplicate Finger
When enrolling a user fingerprint, the fingerprint that has been input already exists in the device (when checking the duplicated case).
!Failed
The number of users exceeds 200, so you cannot enroll more users.
!Not Administrator
A normal user tries to enter the menu.
!Not Authorized
The fingerprint authentication for the administrator fails when entering the menu.
!Wrong PIN
The entered password for authentication is not matched the enrolled
one.
!ID In Use
The user ID to enroll already exists.
!Invalid Value
An invalid value is entered.
!Failed
The user ID to delete does not exist.
!Unknown Finger
The entered fingerprint for entering the menu or editing/deleting a user data does not exist.
!Access Restricted
The authentication trial happens except for the allowed time zone.
!No Log
There is no log data.
!Not Recognizable
The fingerprint data cannot be extracted due to wrong finger input.
!Device Locked
The device is locked because the case has been open.
Page 35
5.2 Troubleshooting
Category
Trouble
Solution
Power
The power is supplied but the device does not operate.
- When the device is disconnected from the bracket, it may not work when using the tamper switch.
- Check the adapter or power cable.
Password
The password is lost.
- Enter the queried password after contacting the administrator in case of a normal user.
- When the administrator password is lost, contact with the installation agency.
The locked door is not open after entering the password and pressing OK.
- Check whether the correct password is input.
- Check whether you have changed the password recently.
- If you cannot find the password, contact the administrator.
Fingerprint
The fingerprint has been enrolled but its recognition encounters an error.
- BioLite Solo has the technology of Suprema that won the first award in FVC2004 and FVC2006 because it has world number one quality in recognition.
- For better performance in fingerprint recognition, correct registration is a must.
- Enroll the fingerprint again after seeing 1.3 Methods for fingerprint input
- The recognition rate may vary due to the characteristic of each finger so enroll the fingerprint of another finger.
It was good at recognizing fingerprints but suddenly it fails in recognition.
- Check whether the finger or the sensor is covered with sweat, moisture, or dust.
- In case the fingerprint has any damage, the device may consider it as the one of wrong person.
- Wipe the finger or sensor with a dry cloth and retry.
- When the fingerprint is so dry, blow your steam of breath into it and retry.
Door lock
Even if you close the door, the door is not locked.
- The electric lock failure is most likely to happen. Check it after contacting the installation agency.
Time
The time is not correct.
- BioLite Solo has an embedded battery but it can be discharged by a long time use. Accordingly the time may not be correct. Correct the time after seeing 3.1 Date, Time.
Administrator connection
The administrator mode cannot be entered because of losing the administrator password or resignation.
- BioLite Solo allows the administrator to give access rights so only the administrator can enter the menu.
- When you have no choice but to enter the administrator menu, you can be granted an administrator password after following the predefined procedure. (Contact with the installation agency.)
Page 36
5.3 Usage summary
It provides the mainly used functions
.
button: Used to select the desired function.
Function
Method for setting
(Sequentially perform the following items.)
Initial administrator registration
Enter ID Select PIN Only for authorization method Enter password Enter password again
Date & time setting
Select Screen, Sound ( ) icon Select Date, Time ( ) icon Enter date Enter time
User registration
Select User ( ) icon Select Enroll ( ) icon Enter ID Select General or Administrator in Level Select authorization method Enter fingerprint or password
User password modification
Select User ( ) icon Select Edit ( ) icon Enter ID or fingerprint Select PIN Enter the desired password Enter it again
User fingerprint modification
Select User ( ) icon Select Edit ( ) icon Enter ID or fingerprint Select Fingerprint Enter the fingerprint of the user
Enter it again
User authorization method modification
Select User ( ) icon Select Enroll ( ) icon Enter ID or fingerprint Select Operation Mode Select an authorization method
User deletion
Select User ( ) icon Select Delete ( ) icon Enter ID or fingerprint to delete
All user deletion
Select Device ( ) icon Select System ( ) icon Select Delete User DB Select Delete
Initialization (Environment settings deletion)
Select Device ( ) icon Select System ( ) icon Select Factory Default Select Initialize
Page 37
5.4 System Installation
5.4.1 Cable specifications
Type
No.
Name
Color
Door open
switch
&
Door open
sensor
1
GND
Black
2
SWIN 1
Brown
3
GND
Black
4
SWIN 0
Purple
Relay
5
Normal Close
Orange (White String)
6
Common
Green (White String)
7
Normal Open
Gray (White String)
Power & 485
8
Power + (12Vdc)
Red
9
Power GND
Black
10
485 GND
White (Black String)
11
485 +
Blue (Black String)
12
485 -
Yellow (Black String)
Page 38
5.4.2 Connecting Power & 485
RS-485 is used when connecting the Secure I/O.
For power supply, use a product of DC 12V (± 10%) and minimum 500mA. (To share the power with other devices, use a power supply with higher current ratings.).
Page 39
5.4.3 Connecting the relay
1. Fail safe lock
2. Fail secure lock
N.O. (Normally Open): A control signal closes the circuit. N.C. (Normally Closed): A control signal opens the circuit. Take care of the direction of the diode. Make sure to install the diode near to the door lock. Make sure to use different power supplies for the BioLite Solo and the door lock. Make sure to install the diode at both ends of the circuit as shown in the figures above (and below) in order to protect the relay contact from the reverse current that occurs when the
Page 40
3. Automatic door
Page 41
5.4.4 Connecting the switch
5.4.5 Electrical specifications
Type
Name
Min.
Typ.
Max.
Notes
Power Voltage (V)
10.8
12
13.2
Use regulated DC power adaptor only
Current (mA)
- 250
Switch Input
VIH (V)
-
TBD
- VIL (V)
-
TBD
Pull-up resistance (Ω )
-
4.7k
-
The input ports are pulled up with 4.7k resistors
Relay
Switching capacity (A)
- - 1
0.3
30V DC 125V AC
Switching power (resistive)
- - 30W
37.5VA
DC AC
Switching voltage (V)
- - 110
125
DC AC
Page 42
5.4.6 Installing the bracket
1. Fix the bracket to the place where BioLite Solo is
to be installed using the fixing screws.
2. Install BioLite Solo on the bracket.
3. Fix BioLite Solo and the wall mount bracket by
rotating the star-shape screw by the hexagonal wrench.
If the installation place is on concrete, drill holes, insert knife blocks into the holes, and fix them by using fixing screws.
Page 43
5.5 Specifications
Item
Specification
CPU
400MHz DSP
Memory
4MB Flash and 8MB RAM
Fingerprint sensor
500dpi optical sensor
User capacity
200 users (2 fingerprints per user)
Matching speed
Less than 1 second
Operation mode
Fingerprint, Password, Fingerprint + Password
LCD
128 x 64 Graphic LCD (Monochrome)
Keypad
3x4 keypad, 3 navigation keys
User interface
Multi-color LED and Multi-tone buzzer
TTL I/O
2 inputs for exit switch and door sensor
Internal relay
Deadbolt, EM lock, door strike, automatic door
IP rate
IP65 class
Log capacity
5,000 events
Timer
RTC Charge-type Backup Battery Embedded
Rated Voltage
DC 12V (Min. 500mA and above)
Size
60 x 185 x 40 mm (Width x Height x Depth)
Page 44