Suprema BEW2-ODP, BEW2-OHP Installation Guide

BioEntry W2
INSTALLATION GUIDE
Version 1.27 English
EN 101.00.BEW2 V1.27A
Contents
Components ................................................................................................................................................... 5
Name and function of each part ............................................................................................................... 6
Cables and connectors......................................................................................................................................................... 7
How to enroll a fingerprint ........................................................................................................................ 8
Selecting a finger for fingerprint input ........................................................................................................................ 8
Fingerprint enroll method ................................................................................................................................................ 8
Fixing the bracket and the product .......................................................................................................... 9
Power supply connection ........................................................................................................................... 11
Network connection .................................................................................................................................... 12
TCP/IP ..................................................................................................................................................................................12
TTL input connection ................................................................................................................................. 13
Relay connection ......................................................................................................................................... 14
Fail Safe Lock ....................................................................................................................................................................14
Fail Secure Lock ................................................................................................................................................................14
Automatic door connection ............................................................................................................................................15
Connecting as a standalone ...................................................................................................................... 16
Connecting to Secure I/O 2 ...................................................................................................................... 17
Wiegand connection ................................................................................................................................... 18
Resetting Network Settings ......................................................................................................................... 18
Restoring the Factory Defaults .................................................................................................................... 18
Dimensions ................................................................................................................................................... 20
Disclaimers ................................................................................................................................................... 22
Copyright notice .......................................................................................................................................... 22
Open Source License .................................................................................................................................... 22
GNU General Public License ..............................................................................................................................................22
GNU Lesser General Public License ..................................................................................................................................28
OpenSSL License ................................................................................................................................................................30
Original SSLeay License .....................................................................................................................................................30

Safety Instructions

Safety Instructions
Observe the following instructions to use the product safely and prevent any risk of injury or property damage.
Warning
Noncompliance of instructions could lead to serious injury or death.
Installation
Do not install the product in a place with direct sunlight, moisture, dust, or soot.
• A fire or electric shock may occur.
Do not install the product in a place with heat from an electric heater.
• A fire or electric shock may occur due to overheating.
Install the product in a dry place.
• Otherwise, a product damage or electric shock may occur due to moisture.
Install the product in a place with no electromagnetic interference.
• Otherwise, a product damage or electric shock may occur.
The user should not install or repair the product independently.
• A fire, electric shock, or personal injury may occur.
If the product has been damaged due to independent installation or repair of the product by the user, free A/S service will not
be provided.
Operation
Do not allow liquids such as water, beverages, or chemicals get into the product.
• A fire, electric shock, or product damage may occur.
Caution
Noncompliance of instructions could lead to minor injury or product damage.
Installation
Do not install the power supply cable in a place where people pass by.
• Product damage or physical injury may occur.
Do not install the product near a highly magnetic object such as a magnet, TV, (especially CRT) monitor, or speaker.
• A product failure may occur.
If installing the product outside where the product is completely exposed, it is recommended to install the product together with the enclosure.
Use a separate power supply for Secure I/O 2, electric lock and BioEntry W2 respectively.
• If connecting and using the power supply to these devices together, the devices may malfunction.
When installing a number of devices, allow a space between the devices for installation.
• Otherwise, one device may affect the RF performance of other devices, resulting in malfunction.
3
Safety Instructions
Operation
Do not drop the product or apply an impact to the product.
• A product failure may occur.
Be careful not to contaminate or damage the fingerprint contact unit with a dirty hand or foreign substances.
• Deterioration in fingerprint authentication performance and a product failure may occur.
When cleaning the product, wipe the product with a soft and dry cloth and no water, benzene or alcohol.
Otherwise, a product failure may occur.
Electronic Access Control Systems, would be invalidated through the use of any add-on, expansion, memory or other module manufactured or supplied by the manufacturer or manufacturers representative.
4

Introduction

BioEntry W2
Wall Bracket
PVC Anchor
Fixing Screw
Diode
120 Ω resistor
Drilling Template
Quick Guide
Ferrite Core
Shrink Tubes
Bracket Fixing Screw
Open Source Software Guide

Components

Introduction
(2 EA)
(1 EA)
NOTE
Components may vary according to the installation environment.
(2 EA)
(Star Shaped)
5

Name and function of each part

RF card authentication unit
Fingerprint authentication unit
TTL input cable
Relay output cable
Resets the network configuration. For details, refer to the Resetting Network Setting.
Restoring the Factory Defaults.
Fingerprint
LED lamp
RF card
authentication unit
LED status indicator for
Network reset button
Cable
authentication unit
Introduction
Network
Name Feature
LED lamp Indicates the operational status of the product with the color of the LED lamp.
Reads RF cards for entering and exiting.
Reads fingerprints placed on it for entering and exiting.
Wiegand input or output cable
Cable
LED lamp for Network Shows the status of the network connection.
Reset button
Power cable
RS485 cable
Ethernet connector
Deletes all data and certificate on the device and reset the settings. For details, refer to the
6

Cables and connectors

and the lead shall not be spliced to a conductor larger than 18 AWG (0.82 mm2).
1
RLY N O
Gray (White stripe)
2
RLY C OM
Green (White stripe)
3
RLY N C
Orange (White stripe)
Blue
Brown
Red
Green
6
WG D0
Green
7
WG D1
White
8
WG GND
Black
9
TTL IN 1
Brown
10
TTL IN 0
Purple
11
PWR +VDC
Red
12
Not Connected
Pink
13
PWR GND
Black (White stripe)
14
485 TRXN
Yellow (Black stripe)
15
485 TRXP
Blue (White stripe)
16
485 GND
White (Black stripe)
17
ENET TXP
White
18
ENET TXN
Orange
19
ENET RXP
Black
20
ENET RXN
Yellow
Introduction
Pin Name Color
4 VB2
5 VB1
NOTE
There are several conductors of size of AWG 26 and they shall be covered by a common jacket or the equivalent when field wiring;
7
Introduction
In preparation for the case that the fingerprint of a specific finger cannot be used, for
or the middle finger when scanning the
1
Place the finger with the fingerprint to be registered on the fingerprint authentication unit and press the finger gently for better authentication.
2
After a beep sounds, scan the fingerprint of the registered finger again (scan the fingerprint of a finger to be registered twice).

How to enroll a fingerprint

In order to improve the fingerprint authentication rate, register the fingerprint correctly. BioEntry W2 can recognize a fingerprint even if the angle and position of a user's fingerprint input change. If you register the fingerprint with attention to the following matters, the authentication rate can be improved.

Selecting a finger for fingerprint input

example if the user is lifting a load with one hand or a finger gets hurt, up to 10 fingerprints for each user can be registered.
In the case of a user whose fingerprint cannot be recognized well, the authentication rate can be improved by enrolling the same finger twice repeatedly.
• If a finger has a cut or the fingerprint is blurry, select another finger for the fingerprint.
• It is recommended to use the index finger
fingerprint. The authentication rate can be reduced if it is difficult to place another finger at the center of fingerprint sensor accurately.

Fingerprint enroll method

NOTE
Cautions for enrolling a fingerprint
When a fingerprint is recognized, it is compared with the initially registered fingerprint, so the initial fingerprint enroll is the most important. Pay attention to the following matters when enrolling the fingerprint.
Place the finger deep enough to contact with the sensor completely.
Place the center of the fingerprint in the center of the sensor.
If a finger has a cut or the fingerprint is blurry, select another finger for the fingerprint.
Scan the fingerprint correctly without moving according to the instruction on the screen.
If you make the finger upright so that the contact area with the sensor has decreased or the angle of finger has warped, fingerprint
authentication may not be performed.
When the fingerprint recognition fails
BioEntry W2 can recognize a fingerprint regardless of a change of season or finger condition. However, the authentication rate may vary according to the external environment or fingerprint input method.
If the fingerprint authentication cannot be done smoothly, it is recommended to take the following measures.
If the finger is smeared with water or sweat, dry off the finger and then scan the finger.
If the finger is too dry, blow your breath on the fingertips and then scan the finger.
If the finger has a cut, register the fingerprint of another finger.
The initially registered fingerprint often may have not been scanned correctly, so register the fingerprint again according to ‘Cautions
for enrolling a fingerprint’.
8

Installation

100 mm
270 mm
120 mm
250 mm
150 mm
170 mm
Installation

Fixing the bracket and the product

1 Determine the correct position to install the bracket using the provided drilling template. Fix the bracket firmly using fixing
screws through the bracket to the position where BioEntry W2 will be installed.
NOTE
If installing BioEntry W2 on a concrete wall, drill holes, insert PVC anchors, and fix them with fixing screws.
To avoid RF interference, a minimum separation distance must be maintained.
Wall
Wall thickness
Distance
Wall thickness Distance
Wall
300 mm
9
2 Install BioEntry W2 onto the fixed bracket.
product fixing screw for enhanced security.
3 Assemble BioEntry W2 with the bracket by rotating the product fixing screw.
Installation
NOTE
When assembling the product with the bracket, you can use the included bracket fixing screw(Star Shaped) instead of the
10
Loading...
+ 22 hidden pages