sensors
H Analyzer
2
Hydrogen Analyzer used for nitriding and other
process gas applications
Nitriding Potential (Kn)
PN: 13537
800 X 480 Color Touch Screen
Included Software for Data Management
Data manager for downloading
Print charts and tabular data
Add notes when capturing data
Graphical display on PC
Export utilities
Portable H Analyzer
PN: 13536
2
Measures H from 0 to 100% with 0.01%
resolution
Calculates NH , DA, and Kn for
nitriding applications
Rechargeable batteries
Ethernet and USB communications
Includes software for data management
Built in sample pump
Rugged enclosure for portable industrial
use
Built in data logging
Color touch-screen
Displays 0 - 100% H
2
Calculates and Displays %DA and Kn
Capable of %DA and Kn with manual input of N and NH flows
General Specifications
Input Voltage: 100 - 240 VAC
Maximum Current Draw: 0.2A @ 120 VAC
Enclosure Weight: 22.5 lbs / 10.2 KG
Analog Outputs: Two 4-20mA outputs common supply and isolated
from other electronics
Output variables: %H , %NH , %DA, and Kn on either
output
Field calibration for zero and span
Ethernet and USB communications
Hydrogen measurement:
Range: 0 to 100%
Accuracy: +/- 0.01%
Repeatability: +/- 0.01%
Resolution: +/- 0.01%
2
3
2
3
Sample flow rate:
1.5-2 cfh
2
3
INNOVATIVE SOLUTIONS WORLDWIDE
S04-03201023-003
SuperSystems
incorporated
OEM H Sensor
2
PN: 20624
Features
Measures H from 0 to 100% with 0.01% resolution
Calculates NH , DA, and Kn for nitrider applications
Two isolated 4-20mA analog outputs
One RS232 port with Modbus RTU or a simple ASCII
protocol
One RS485 port with Modbus RTU protocol
Wide power supply input range (9-30 VDC)
Temperature and Humidity:
Electronics: 0 to 50 C, RH to 90% non-condensing
Sample Gas: 0 to 70 C, RH 0 to 90% non-
condensing
Storage: -20 to 70 C, H 0 to 90% non-condensing
2
3
o
o
o
Specifications
RS-232 Serial Communications:
Protocols: Modbus RTU or simple ASCII
Baud Rates: 9600, 19200, or 38400
Format: 8 bits, no parity; 1 stop bit, no handshaking
Connection: DB-9P
RS-485 Serial Communications:
Protocol: Modbus RTU
Baud Rates: 9600, 19200, or 38400
Format: 8 bits, no parity; 1 stop bit, no handshaking
Analog Outputs:
Two 4-20mA outputs common supply and isolated from
other electronics
Output variables: %H , %NH , %DA, and Kn on either
output
Adjustable range of PV: zero and span
Resolution: 0.005 mA
Accuracy: +/- 0.01% of range
Linearity: +/- 0.01%
Minimum load resistance: 0 ohm
Maximum load resistance: 500 Ω
2
3
Hydrogen measurement:
Range: 0 to 100%
Accuracy: +/- 0.01%
Repeatability: +/- 0.01%
Resolution: +/- 0.01%
Material:
Stainless steel sensor housing
SuperSystems
7205 Edington Drive
Cincinnati, OH 45249
513.772.0060 phone
513.772.9466 fax
incorporated
Sample flow rate:
1.5-2 cfh
Power requirement:
9 to 30 volts DC @ 2 watts
Weight:
350g
www.supersystems.com 800.666.4330