Super System OEM H2 User Manual

H Analyzer
2
Hydrogen Analyzer used for nitriding and other process gas applications
Nitriding Potential (Kn)
PN: 13537
800 X 480 Color Touch Screen
Included Software for Data Management
Data manager for downloading
Print charts and tabular data Add notes when capturing data Graphical display on PC Export utilities
Portable H Analyzer
PN: 13536
2
Measures H from 0 to 100% with 0.01%
resolution Calculates NH , DA, and Kn for nitriding applications Rechargeable batteries Ethernet and USB communications Includes software for data management Built in sample pump Rugged enclosure for portable industrial use Built in data logging Color touch-screen
Displays 0 - 100% H
2
Calculates and Displays %DA and Kn
Capable of %DA and Kn with manual input of N and NH flows
General Specifications
Input Voltage: 100 - 240 VAC Maximum Current Draw: 0.2A @ 120 VAC Enclosure Weight: 22.5 lbs / 10.2 KG
Analog Outputs: Two 4-20mA outputs common supply and isolated
from other electronics Output variables: %H , %NH , %DA, and Kn on either output
Field calibration for zero and span Ethernet and USB communications
Hydrogen measurement:
Range: 0 to 100% Accuracy: +/- 0.01% Repeatability: +/- 0.01% Resolution: +/- 0.01%
2
3
2
3
Sample flow rate:
1.5-2 cfh
2
3
INNOVATIVE SOLUTIONS WORLDWIDE
S04-03201023-003
SuperSystems
incorporated
OEM H Sensor
2
PN: 20624
Features
Measures H from 0 to 100% with 0.01% resolution Calculates NH , DA, and Kn for nitrider applications Two isolated 4-20mA analog outputs One RS232 port with Modbus RTU or a simple ASCII protocol One RS485 port with Modbus RTU protocol Wide power supply input range (9-30 VDC)
Temperature and Humidity:
Electronics: 0 to 50 C, RH to 90% non-condensing Sample Gas: 0 to 70 C, RH 0 to 90% non-
condensing Storage: -20 to 70 C, H 0 to 90% non-condensing
2
3
o
o
o
Specifications
RS-232 Serial Communications:
Protocols: Modbus RTU or simple ASCII Baud Rates: 9600, 19200, or 38400 Format: 8 bits, no parity; 1 stop bit, no handshaking Connection: DB-9P
RS-485 Serial Communications:
Protocol: Modbus RTU Baud Rates: 9600, 19200, or 38400 Format: 8 bits, no parity; 1 stop bit, no handshaking
Analog Outputs:
Two 4-20mA outputs common supply and isolated from other electronics Output variables: %H , %NH , %DA, and Kn on either output
Adjustable range of PV: zero and span Resolution: 0.005 mA Accuracy: +/- 0.01% of range Linearity: +/- 0.01% Minimum load resistance: 0 ohm Maximum load resistance: 500 Ω
2
3
Hydrogen measurement:
Range: 0 to 100% Accuracy: +/- 0.01% Repeatability: +/- 0.01% Resolution: +/- 0.01%
Material:
Stainless steel sensor housing
SuperSystems
7205 Edington Drive
Cincinnati, OH 45249
513.772.0060 phone
513.772.9466 fax
incorporated
Sample flow rate:
1.5-2 cfh
Power requirement:
9 to 30 volts DC @ 2 watts
Weight:
350g
www.supersystems.com 800.666.4330