Super System DPL4000 User Manual

sensors
DPL4000
Portable low range dew point system for accurate and reliable verification of gases using current sensor technology.
LOW RANGE DEW POINT MEASUREMENT
TECHNICAL FEATURES
Optimal dew point range
-112 to -22 F with +/- 3.6 F accuracy
-80 to -30 C with +/- 2 C accuracy
Operating temperature
-40 to +140 F
-40 to + 60 C
Pressure range: 0 to 725 psi Alarm indication Sensor threads: ‰ NPT Sensor housing: IP65  NEMA4 (AISI316L)
o
o
o
o
oo
o
o
Determine very low dew points with high accuracy Excellent long term stability Rapid response time with fast stabilizing dew point reading Withstands condensation Includes hand held instrument, sensor, sensor housing, flow meter, quick connect fittings, logging software, and protective carrying case
Typical DP Gas Measurements
Hydrogen
Argon
Nitrogen
OTHER FEATURES
Durable handheld Easy to read LCD display
Units: Dew point ( F or C), Frost point, ppm (by weight), ppb (by voume) Process variable trending and data logging Battery powered Rechargeable battery included Battery run time: 12 hours
Sensor Quick Disconnect Includes two male quick disconnect fittings
USB Cable and Utility Software Quickly retrieve data from handheld device
INNOVATIVE SOLUTIONS WORLDWIDE
S01-07200927-001
o
o
SuperSystem
incorporated
s
Special Features
Quick Response
Easy to Use
Sensor Purge
This function evaporates all excess moisture molecules from the sensor to significantly increase the response time when the sensor goes from an ambient condition to a dry condition. A Sensor Purge will be initiated automatically when the sensor detects a large wet-to-dry environmental change or upon startup and after every 24 hours of continuous use.
Specifications
This device is used to measure very low dew points with high accuracy and excellent long term stability. It can be used across a wide range of temperatures and pressures. It measures dew point in a variety of non­corrosive gases including Nitrogen, Argon, and Hydrogen.
Total Measurement Range: -148F to +68F (-100C to +20C) Optimal Measurement Range: -112F to -22F (-80C to -30C) Accuracy (Within Optimal Range): +/- 3.6F (+/- 2C) Accuracy (Outside Optimal Range): +/- 5.4F (+/- 3C) Operating Temperature Range: -40F to +140F (-40C to +60C) Operating Pressure Range: 0-725 psi / 0-50 bar Sensor Housing: IP65 - NEMA4 (AISI316L) Power: Rechargeable Battery (included) or 4 "AA" Batteries Battery Recharging Time: Approximately 4 hours Run Time on Battery Power: Approximately 12 hours (depends on application) Output Units: Dew Point /Frost Point, ppm (by weight), ppb (by volume)