X10SRW-F
USER’S MANUAL
Revision 1.1
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver
is connected.
• Consult the authorized dealer or an experienced radio/TV technician for help.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other reproductive harm.
Manual Revision 1.1
Release Date: August 23, 2016
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2016 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
Preface
This manual is written for system integrators, IT professionals, and
knowledgeable end users. It provides information for the installation and use of the
X10SRW-F motherboard.
About This Motherboard
The X10SRW-F supports a single Intel® E5-2600/1600 Series Processor in
an LGA2011 R3 socket. With the Intel® C612 Express chipset built in, the X10SRW-
F motherboard supports Intel® Server Platform Services (Intel SPS), offering great
system enhancement to high performance storage platforms. Please refer to our
website (http://www.supermicro.com/products/) for processor and memory support
updates. This product is intended to be installed and serviced by professional
technicians.
Manual Organization
Chapter 1 describes the features, specications and performance of the mother-
board, and provides detailed information on the Intel® C612 Express chipset.
Chapter 2 provides hardware installation instructions. Read this chapter when in-
stalling the processor, memory modules and other hardware components into the
system. If you encounter any problems, see Chapter 3 , which describes trouble-
shooting procedures for video, memory and system setup stored in the CMOS.
Chapter 4 includes an introduction to the BIOS, and provides detailed information
on running the CMOS Setup utility.
Appendix A provides BIOS Error Beep Codes.
Appendix B lists software program installation instructions .
Appendix C contains UEFI BIOS Recovery instructions.
Appendix D contains Dual Boot Block instructions.
Preface
iii
X10SRW-F User’s Manual
Conventions Used in the Manual:
Special attention should be given to the following symbols for proper system instal-
lation:
Warning: Critical information given to prevent damage to the components or injury
to yourself.
Note: Additional Information provided for correct system setup.
iv
Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Web Site: www.supermicro.nl
Contacting Supermicro
Asia-Pacic
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3992
Email: support@supermicro.com.tw
Web Site: www.supermicro.com.tw
v
X10SRW-F User’s Manual
Table of Contents
Preface
Chapter 1 Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Chipset Overview ......................................................................................... 1-10
1-3 Special Features ............................................................................................1-11
1-4 PC Health Monitoring .....................................................................................1-11
1-5 ACPI Features ............................................................................................... 1-12
1-6 Power Supply ................................................................................................ 1-12
1-7 Super I/O ....................................................................................................... 1-13
Chapter 2 Installation
2-1 Standardized Warning Statements ................................................................. 2-1
2-2 Static-Sensitive Devices .................................................................................. 2-4
2-3 Motherboard Installation .................................................................................. 2-5
2-4 Processor and Heatsink Installation................................................................ 2-7
Installing the LGA2011 Processor .................................................................2-7
Installing a Passive CPU Heatsink ................................................................2-11
Removing the Heatsink ................................................................................. 2-12
2-5 Installing DDR4 Memory ............................................................................... 2-13
DIMM Installation .......................................................................................... 2-13
Removing Memory Modules ......................................................................... 2-14
Memory Support ............................................................................................ 2-14
Memory Population Guidelines ..................................................................... 2-15
2-6 Connectors/IO Ports ...................................................................................... 2-17
Backplane I/O Panel ..................................................................................... 2-17
Universal Serial Bus (USB) ...................................................................... 2-18
Ethernet Ports .......................................................................................... 2-19
Serial Ports (COM1/COM2)...................................................................... 2-19
Unit Identier Switch/UID LED Indicator .................................................. 2-20
VGA Port ..................................................................................................2-20
Front Control Panel ....................................................................................... 2-21
Front Control Panel Pin Denitions ............................................................... 2-22
NMI Button ............................................................................................... 2-22
Power LED .............................................................................................. 2-22
HDD LED .................................................................................................. 2-23
NIC1/NIC2 LEDs ...................................................................................... 2-23
Overheat (OH)/Fan Fail/PWR Fail/UID LED ............................................ 2-24
vi
Table of Contents
Power Fail LED ........................................................................................ 2-24
Reset Button ........................................................................................... 2-25
Power Button ........................................................................................... 2-25
2-7 Connecting Cables ........................................................................................ 2-26
ATX Main PWR & CPU PWR Connectors (J24 & JPWR1) ..................... 2-26
Fan Headers (Fan 1-2, Fan 4-7) .............................................................. 2-27
Chassis Intrusion (JL1) ........................................................................... 2-27
Internal Speaker/Buzzer (SP1) ................................................................ 2-28
DOM PWR Connector (JSD1) .................................................................. 2-29
Standby Power ......................................................................................... 2-29
T-SGPIO 1/2/3 Headers ........................................................................... 2-30
Power SMB (I2C) Connector .................................................................... 2-30
TPM Header/Port 80 Header ................................................................... 2-31
2-8 Jumper Settings ............................................................................................ 2-32
Explanation of Jumpers ................................................................................ 2-32
LAN1/LAN2 Enable/Disable ..................................................................... 2-32
CMOS Clear (JBT1) ................................................................................. 2-33
PCI-E Slot SMB Enable (I2C1/I2C2) ......................................................... 2-33
VGA Enable .............................................................................................. 2-34
Watch Dog Enable/Disable ...................................................................... 2-35
2-9 Onboard Indicators ........................................................................................ 2-36
LAN 1/LAN 2 LEDs .................................................................................. 2-36
IPMI Dedicated LAN LEDs ....................................................................... 2-36
BMC Heartbeat LED (LEDM1) ................................................................. 2-37
Unit Identication LED (LE1) .................................................................... 2-37
Onboard Power LED (LE2) ..................................................................... 2-38
2-10 SATA Connections ......................................................................................... 2-39
SATA/SAS Connections ........................................................................... 2-39
Chapter 3 Troubleshooting
3-1 Troubleshooting Procedures ........................................................................... 3-1
3-2 Technical Support Procedures ........................................................................ 3-3
3-3 Frequently Asked Questions ........................................................................... 3-4
3-4 Battery Removal and Installation .................................................................... 3-5
3-5 Returning Merchandise for Service................................................................. 3-6
Chapter 4 BIOS
4-1 Introduction ...................................................................................................... 4-1
Starting BIOS Setup Utility .............................................................................. 4-1
How To Change the Conguration Data ......................................................... 4-1
vii
X10SRW-F User’s Manual
How to Start the Setup Utility ......................................................................... 4-2
4-2 Main Setup ...................................................................................................... 4-2
The following Main menu items will be displayed: ..................................... 4-2
System Date/System Time ........................................................................ 4-3
Supermicro X10SRW-F .............................................................................. 4-3
BIOS Version: This item displays the version of the BIOS ROM used in the
system. ....................................................................................................... 4-3
Build Date: This item displays the date when the version of the BIOS ROM
used in the system was built. ................................................................... 4-3
Memory Information ................................................................................... 4-3
Total Memory: This item displays the total size of memory available in the
system. ....................................................................................................... 4-3
Memory Speed: This item displays the default speed of the memory
modules installed in the system.. ............................................................... 4-3
4-3 Advanced Setup Congurations ...................................................................... 4-4
Boot Feature ................................................................................................. 4-4
Quiet Boot .................................................................................................. 4-4
AddOn ROM Display Mode ........................................................................ 4-4
Bootup Num-Lock ....................................................................................... 4-4
Wait For 'F1' If Error ................................................................................... 4-5
INT19 (Interrupt 19) Trap Response .......................................................... 4-5
Re-try Boot ................................................................................................. 4-5
Power Conguration ........................................................................................ 4-5
DeepSx Power Policies .............................................................................. 4-5
Watch Dog Function ................................................................................... 4-5
Power Button Function ............................................................................... 4-5
Restore on AC Power Loss ........................................................................ 4-6
Chipset Conguration ................................................................................... 4-6
CPU Conguration ..................................................................................... 4-6
Clock Spread Spectrum ............................................................................. 4-6
Hyper-Threading ......................................................................................... 4-7
Performance/Watt ....................................................................................... 4-7
Execute Disable Bit (Available if supported by the OS & the CPU) .......... 4-7
PPIN Control .............................................................................................. 4-7
Hardware Prefetcher (Available when supported by the CPU) ................. 4-7
Adjacent Cache Line Prefetch (Available when supported by the CPU) ... 4-7
DCU Streamer Prefetcher (Available when supported by the CPU) ......... 4-7
DCU IP Prefetcher...................................................................................... 4-8
viii
Table of Contents
DCU (Data Cache Unit) Mode ................................................................... 4-8
Direct Cache Access (DCA) ....................................................................... 4-8
DCA Prefetch Delay ................................................................................... 4-8
X2APIC (Extended Advanced Programmable Interrupt Controller) ........... 4-8
AES-NI ........................................................................................................ 4-8
Intel Virtualization Technology .................................................................... 4-8
Advanced Power Management Conguration ............................................. 4-9
Chipset Conguration .................................................................................4-11
North Bridge ................................................................................................4-11
IIO Conguration .........................................................................................4-11
Intel VT for Directed I/O (VT-d) ................................................................ 4-13
QPI (Quick Path Interconnect) Conguration ............................................ 4-13
South Bridge ............................................................................................... 4-17
Legacy USB Support ................................................................................ 4-17
XHCI Hand-Off ......................................................................................... 4-17
EHCI Hand-Off ......................................................................................... 4-17
USB Mass Storage Driver Support .......................................................... 4-17
Port 60/64 Emulation ................................................................................ 4-17
USB 3.0 Support ...................................................................................... 4-17
EHCI1 ....................................................................................................... 4-17
EHCI2 ....................................................................................................... 4-18
XHCI Pre-Boot Drive ................................................................................ 4-18
XHCI Idle L1 ............................................................................................. 4-18
PCH DMI ASPM ....................................................................................... 4-18
SATA Conguration .................................................................................... 4-18
SATA Controller ........................................................................................ 4-18
Congure SATA as ................................................................................... 4-18
*If the item above "Congure SATA as" is set to IDE, the following items
will display: ............................................................................................... 4-19
*If the item above "Congure SATA as" is set to RAID, the following items
will display: ............................................................................................... 4-20
sSATA Conguration ................................................................................... 4-21
sSATA Controller ...................................................................................... 4-21
Congure sSATA as ................................................................................. 4-21
*If the item above "Congure sSATA as" is set to IDE, the following items
will display: ............................................................................................... 4-22
*If the item above "Congure sSATA as" is set to RAID, the following items
will display: ............................................................................................... 4-22
Server ME (Management Engine) Conguration ....................................... 4-23
ix
X10SRW-F User’s Manual
PCIe/PCI/PnP Conguration ...................................................................... 4-23
The following PCI information will be displayed: ..................................... 4-23
PCI AER (Advanced Error-Reporting) Support ........................................ 4-24
VGA Palette Snoop .................................................................................. 4-24
PERR# Generation Support ..................................................................... 4-24
SERR# Generation Support ..................................................................... 4-24
Above 4G Decoding (Available if the system supports 64-bit PCI decoding)
4-24
SR-IOV Support (Available if the system supports Single-Root
Virtualization) ............................................................................................ 4-24
Maximum Payload .................................................................................... 4-24
Maximum Read Request .......................................................................... 4-24
ASPM Support .......................................................................................... 4-24
MMIOHBase ............................................................................................. 4-25
MMIO High Size ....................................................................................... 4-25
RSC-R2UW-2E8R Slot1 PCI-E x8 (OPROM)/RSC-R2UW-4E8 Slot4 PCI-E
x8 (OPROM)/RSC-R2UW-4E8 Slot3 PCI-E x8 (OPROM)/RSC-R2UW-4E8
Slot1 PCI-E x8 (OPROM)/ RSC-R2UW-4E8 Slot2 PCI-E x8 (OPROM) . 4-25
Onboard LAN1 Option ROM/Onboard LAN2 Option ROM ...................... 4-25
VGA Priority .............................................................................................. 4-25
Network Stack .......................................................................................... 4-25
Ipv6 PXE Support (Available when Network Stack is set to Enabled) .... 4-25
Super IO Conguration ............................................................................. 4-26
Serial Port 1 Conguration/Serial Port 2 Conguration ........................ 4-26
Serial Port 1/Serial Port 2 ........................................................................ 4-26
Device Settings ........................................................................................ 4-26
Change Port 1 Settings/Change Port 2 Settings ..................................... 4-26
Serial Port 2 Attribute ............................................................................... 4-26
Serial Port Console Redirection ................................................................. 4-26
COM 1 Console Redirection .................................................................... 4-26
COM1 Console Redirection ....................................................................... 4-27
SOL/COM2 ............................................................................................... 4-28
SOL/COM2 Console Redirection ............................................................. 4-28
SOL/COM2 Console Redirection Settings ................................................. 4-28
Serial Port for Out-of-Band Management/Windows Emergency Management
Services (EMS) ........................................................................................ 4-30
EMS (Emergency Management Services) Console Redirection ............. 4-30
EMS Console Redirection Settings ............................................................ 4-30
Trusted Computing (Available when a TPM device is installed and detected
by the BIOS) ................................................................................................. 4-31
x
Table of Contents
Conguration ............................................................................................ 4-31
Security Device Support ........................................................................... 4-31
TPM State ................................................................................................ 4-31
Pending Operation ................................................................................... 4-31
Current Status Information ....................................................................... 4-31
ACPI Settings ............................................................................................ 4-32
WHEA Support ......................................................................................... 4-32
4-4 Event Logs .................................................................................................... 4-33
Change SMBIOS Event Log Settings ....................................................... 4-33
Enabling/Disabling Options ...................................................................... 4-33
SMBIOS Event Log .................................................................................. 4-33
Runtime Error Logging Support ............................................................... 4-33
Memory Corrected Error Enabling (Available when the item above-Runtime
Error Logging Support is set to Enable) .................................................. 4-33
PCI-Ex (PCI-Express) Error Enable ......................................................... 4-33
Memory Correctable Error Threshold ....................................................... 4-33
Erasing Settings ....................................................................................... 4-34
Erase Event Log ....................................................................................... 4-34
When Log is Full ...................................................................................... 4-34
SMBIOS Event Log Standard Settings .................................................... 4-34
Log System Boot Event ........................................................................... 4-34
MECI (Multiple Event Count Increment) .................................................. 4-34
METW (Multiple Event Count Time Window) ........................................... 4-34
View System Event Log ........................................................................... 4-34
4-5 IPMI ............................................................................................................... 4-35
IPMI Firmware Revision ........................................................................... 4-35
IPMI Status ............................................................................................... 4-35
System Event Log ..................................................................................... 4-35
Enabling/Disabling Options ...................................................................... 4-35
SEL Components ..................................................................................... 4-35
Erasing Settings ....................................................................................... 4-35
Erase SEL ................................................................................................ 4-35
When SEL is Full ...................................................................................... 4-36
BMC Network Conguration ...................................................................... 4-36
IPMI LAN Selection .................................................................................. 4-36
IPMI Network Link Status ......................................................................... 4-36
Update IPMI LAN Conguration ............................................................... 4-36
Conguration Address Source ................................................................. 4-36
xi
X10SRW-F User’s Manual
4-6 Security Settings ........................................................................................... 4-38
Password Check ...................................................................................... 4-38
Administrator Password ........................................................................... 4-38
4-7 Boot Settings ................................................................................................. 4-39
Setup Prompt Timeout ............................................................................. 4-39
Boot Mode Select ..................................................................................... 4-39
Fixed Boot Order Priorities ....................................................................... 4-39
Add New Boot Option .............................................................................. 4-40
Boot Option File Path ............................................................................... 4-40
Delete Boot Option ................................................................................ 4-40
4-8 Save & Exit ................................................................................................... 4-41
Discard Changes and Exit ...................................................................... 4-41
Save Changes and Reset ........................................................................ 4-41
Save Options ............................................................................................ 4-41
Save Changes .......................................................................................... 4-41
Discard Changes ...................................................................................... 4-41
Restore Defaults ....................................................................................... 4-41
Save As User Defaults ............................................................................. 4-42
Restore User Defaults .............................................................................. 4-42
Boot Override ........................................................................................... 4-42
Appendix A BIOS Error Beep Codes
A-1 BIOS Error Beep Codes .................................................................................A-1
Appendix B Software Installation Instructions
B-1 Installing Software Programs ..........................................................................B-1
B-2 Installing SuperDoctor5 ...................................................................................B-2
Appendix C UEFI BIOS Recovery Instructions
C-1 An Overview to the UEFI BIOS ......................................................................C-1
C-2 How to Recover the UEFI BIOS Image (-the Main BIOS Block)....................C-1
C-3 To Recover the Main BIOS Block Using a USB-Attached Device..................C-1
Appendix D Dual Boot Block on Grantley Platforms
D-1 IPMI GUI Browser ...........................................................................................D-2
D-2 IPMI Command Sets .......................................................................................D-7
User Approach ............................................................................................................D-9
xii
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
Checklist
Congratulations on purchasing your computer motherboard from an acknowledged
leader in the industry. Supermicro boards are designed with the utmost attention to
detail to provide you with the highest standards in quality and performance.
Please check that the following items have all been included with your motherboard.
If anything listed here is damaged or missing, contact your retailer.
The following items are included in the retail box:
• One (1) Supermicro Motherboard
• Ten (10) SATA cables
• One (1) I/O shield
• One (1) Quick Reference Guide
Note: For your system to work properly, please follow the links below to
download all necessary drivers/utilities and the user's manual for your
motherboard.
Supermciro product manuals: http://www.supermicro.com/support/manuals/
Product Drivers and utilities: ftp://ftp.supermicro.com/
If you have any questions, please contact our support team at support@supermicro.
com.
1-1
X10SRW-F User’s Manual
X10SRW-F Motherboard Image
Note: All graphics shown in this manual were based upon the latest PCB Revision
available at the time of publishing of the manual. Your motherboard or components
may or may not look exactly the same as the graphics shown in this manual.
1-2
X10SRW-F Motherboard Layout
Chapter 1: Introduction
MAC CODE
BAR CODE
IPMI CODE
JSD2
SATA4
UID
LE1
JUIDB1
BIOS
LICENSE
JBRSET1
SXB1_1
SXB2
2-3:DISABLE
LAN1
1-2:ENABLE
JPL2
JPL3
LAN2
2-3:DISABLE
1-2:ENABLE
1-2:NORMAL
JPME2:
2-3:ME MANUFACTURE MODE
2-3:BIOS RECOVERY
1-2:NORMAL
I-SATA1
SXB1_2
SXB1_3
I-SATA0
I-SATA3
I-SATA2
VGA
DM1
LAN2
USB0/1(3.0)
LAN1
USB2/3
IPMI_LAN
JPL1
DM2
LEDM1
JPG1
JPME2
JWD1
2-3:NMI
JWD:Watch Dog
1-2:RST
JBR1
JBR1
JBT1
JPB1
1-2:ENABLE
JPB1:BMC
2-3:DISABLE
S-SATA3
S-SATA1
S-SATA2
S-SATA0
JPG1:VGA
1-2:ENABLE
2-3:DISABLE
BT1
JPF1
ON:POWER FORCE ON
JI2C1/2:
I2C BUS FOR PCI-E SLOT
2-3:DISABLE
1-2:ENABLE
INTRUSION JL1:
CHASSIS
T-SGPIO3
(SATA SGPIO2)
T-SGPIO2
(SATA SGPIO1)
T-SGPIO1
(SATA SGPIO0)
USB9/10
JOH1
X10SRW-F
REV: 1.01
DESIGNED IN USA
CPU
JIPMB1
COM1
JPF2
123
IPMI
4
COM2
JF1
ON
JPL1/LAN
1-2:ENABLE
2-3:DISABLE
TPM/PORT80
JI2C2 J29
JTPM1
JI2C1
LEDLED12LEDFAIL
NMIXPWRHDDNICNICUIDPSRSTPWR
USB4/5
J30
111
USB6/7
SP1
JPF1
USB8(3.0)
J23
T-SGPIO3
1
T-SGPIO2
T-SGPIO1
JUSB3-1A
USB11/12(3.0)
JD1:
SPEAKER-PIN 4-7
PWR LED-PIN 1-3
JD1
LE2
JF1
JPI2C1
JSTBY1
JSD1
SATA5
1
LGA2011-3
1
JPWR1
DIMMD1
DIMMD2
DIMMC1
DIMMC2
JL1
JP4
FAN5
FAN6
FAN7
FAN4
FAN3
DIMMB2
DIMMB1
JVR1
DIMMA2
DIMMA1
FAN2
J24
FAN1
Notes:
• See Chapter 2 for detailed information on jumpers, I/O ports and JF1 front
panel connections.
• " " indicates the location of "Pin 1".
• Jumpers not indicated are for testing only.
• When the onboard Power LED Indicator (LE2) is on, system power is on.
Unplug the power cable before installing or removing any components.
1-3
X10SRW-F User’s Manual
X10SRW-F Quick Reference
MAC CODE
BAR CODE
IPMI CODE
JSD2
SATA4
JP4
JPL1
USB9/10
JIPMB1
COM1
123
IPMI
4
COM2
JF1
ON
JPL1/LAN
1-2:ENABLE
2-3:DISABLE
TPM/PORT80
JI2C2 J29
JTPM1
JI2C1
LEDLED12LEDFAIL
NMIXPWRHDDNICNICUIDPSRSTPWR
USB4/5
J30
111
USB6/7
SP1
JPF2
JPF1
USB8(3.0)
J23
T-SGPIO3
1
T-SGPIO2
T-SGPIO1
JUSB3-1A
USB11/12(3.0)
JD1:
SPEAKER-PIN 4-7
PWR LED-PIN 1-3
JD1
LE2
JOH1
JF1
JPI2C1
JSTBY1
JPWR1
J24
FAN1
UID
LE1
JUIDB1
SXB1_1
2-3:ME MANUFACTURE MODE
I-SATA1
SXB1_2
SXB1_3
I-SATA0
I-SATA3
I-SATA2
JSD1
SATA5
JL1
FAN5
FAN6
FAN7
VGA
BIOS
LICENSE
JBRSET1
SXB2
2-3:DISABLE
LAN1
1-2:ENABLE
JPL2
JPL3
LAN2
2-3:DISABLE
1-2:ENABLE
1-2:NORMAL
JPME2:
2-3:NMI
JWD:Watch Dog
1-2:RST
2-3:BIOS RECOVERY
1-2:NORMAL
JBR1
JPB1
2-3:DISABLE
DM1
JPME2
JWD1
JBR1
JBT1
1-2:ENABLE
JPB1:BMC
S-SATA3
S-SATA1
S-SATA2
S-SATA0
LGA2011-3
DIMMD1
DIMMD2
DIMMC1
DIMMC2
FAN4
LAN2
LEDM1
X10SRW-F
REV:1.01
DESIGNED IN USA
CPU
1
FAN3
USB0/1(3.0)
LAN1
JPG1
USB2/3
IPMI_LAN
DM2
BT1
JPF1
JPG1:VGA
ON:POWER FORCE ON
1-2:ENABLE
JI2C1/2:
I2C BUS FOR PCI-E SLOT
2-3:DISABLE
1-2:ENABLE
2-3:DISABLE
INTRUSION JL1:
CHASSIS
T-SGPIO3
(SATA SGPIO2)
T-SGPIO2
(SATA SGPIO1)
T-SGPIO1
(SATA SGPIO0)
1
DIMMB2
DIMMB1
DIMMA2
DIMMA1
JVR1
FAN2
X10SRW-F Jumpers
Jumper Description Default
JBR1 BIOS Recovery Pins 1-2 (Normal)
JBRSET1 FIQ Request Pins 1-2 (Normal)
JBT1 CMOS Clear Short: Clear CMOS, Open: Normal Operation
2
C1/JI2C2 SMB to PCI-E Slots Pins 2-3 (Disabled)
JI
JPB1 BMC Enable/Disable Pins 1-2 (Enabled)
JPG1 VGA Enable Pins 1-2 (Enabled)
JPL1 LAN Enable Pins 1-2 (Enabled)
JWD1 Watch Dog Enable Pins 1-2 (Reset)
1-4
Chapter 1: Introduction
X10SRW-F Headers/Connectors
Connector Description
BT1 Onboard Battery
COM1/COM2 COM1 (Port)/COM2 (Header)
FAN1-2, FAN4-7 System/CPU Fan Headers
J24 24-pin Main ATX Power Connector
JD1 Speaker/Buzzer (Pins 1-3: Power LED, Pins 4-7: Speaker)
JF1 Front Panel Control Header
JIPMB1 System Management Bus Header for the IPMI Slot
JL1 Chassis Intrusion Header
JOH1 Overheat LED/Fan Fail
2
JPI
C1 Power SMB (System Management Bus)
JPWR1 8-pin CPU Power Connector
JSD1/JSD2 SATA DOM (Device_On_Module) Power Connector
JSTBY1 Standby Power Header
JTPM1 Trusted Platform Module/Port 80 Connector
JUIDB1 UID (Unit Identication) Button
JVR1 PWM SMB Programming (for debugging only)
LAN1/LAN2 Gigabit (RJ45) Ports (LAN1/2)
IPMI_LAN IPMI_Dedicated LAN
I-SATA 0-3
S-SATA 0-3
(Intel PCH) Serial ATA (SATA 3.0) Ports 0-3
S-SATA Ports 0-3 (6Gb/sec)
SATA 4/5 SATA DOM (Disk_On_Module) Ports 4/5
SP1 Internal Speaker/Buzzer
SXB1A, SXB1B,
SMC-Proprietary WIO_L (Left) Add-On Card slots
SXB1C
SXB2 SMC-Proprietary WIO_R (Right) Add-On Card slot
T-SGPIO 1/2/3 Serial_Link General Purpose I/O Headers 1/2/3 for SATA Connections
UID SW Unit Indentier Switch
USB 0/1 Backpanel USB 3.0 Ports 0/1
USB 2/3 Backpanel USB 2.0 Ports 2/3
USB 4/5, 6/7, 9/10 Front Panel Accessible USB 2.0 Headers 4/5, 6/7, 9/10
USB 8 USB 3.0 Type A Header
USB 11/12 (3.0) Front Panel Accessible USB 3.0 Port 11/12
VGA Backpanel VGA Port
1-5
X10SRW-F User’s Manual
X10SRW-F LED Indicators
LED Description State/Color Status
LE1 UID LED Blue: On Unit Identied
LEDM1 BMC Heartbeat LED Green: Blinking BMC Normal
1-6
Chapter 1: Introduction
Motherboard Features
CPU Single Intel ® E5-2600/1600 Series Processor in an
LGA2011 R3 socket.
Note: Both E5-2600v4 and E5-1600v4 re-
quire Revision 2.0 BIOS (or higher).
Memory Eight (8) ECC DDR4 RDIMM/LRDIMM/UDIMM at 2400
MHz (max.) memory (1 DPC) up to 256GB RDIMM, 512GB
LRDIMM, or 64GB UDIMM.
Dual-channel memory
DIMM sizes
RDIMM 1GB, 2 GB, 4GB, 8GB, 16GB, and
32GB
Chipset Intel
Expansion Slots PCI Slots
Network Intel i350 Dual Gigabit LAN controller
I/O Devices SATA/SAS Connections
®
C612 Express
One (1) SMC-Proprietary WIO Left Add-On card slot
One (1) standard PCIe Right Add-On card slot
Two (2) RJ-45 rear I/O panel connectors with Link and
Activity LEDs
Ten (10) SATA ports
• AHCI controller supports six (6)
SATA3 devices compatible with
RAID 0, 1, 5, 10
• sSATA controller supports four
SATA 3.0 (6Gb/s)
(4) SATA3 devices compatible
with RAID 0, 1, 10
• RAID configurations cannot
cross the two (AHCI and sSATA)
controllers
SATA DOM Two (2) SATA DOM Ports (SATA 4/5)
USB Devices
Eight (8) USB 2.0 ports ( 2 rear, 6 via headers)
Four (4) USB 3.0 headers for USB 3.0 support (2 rear, 1
Type-A, 1 via header)
Serial (COM) Ports
Two (2) COM Ports (1 header, 1 rear)
1-7
X10SRW-F User’s Manual
Graphics Controller
AST 2400 Graphics Controller
BIOS 128 Mb AMI BIOS
Plug and Play (PnP), DMI 2.3, PCI 2.3, ACPI 1.0/2.0/3.0,
USB Keyboard and SMBIOS 2.5
Power Conguration ACPI/ACPM Power Management
Main Switch Override Mechanism
Keyboard Wake-up from Soft-Off
Power-on mode for AC power recovery
PC Health Monitoring CPU Monitoring
Onboard voltage monitors for CPU core, +3.3V, +5V,+12V,
+3.3V Stdby, VBAT, Memory, PCH and BMC voltage
CPU 5-phase switching voltage
CPU/System overheat LED and control
CPU Thermal Trip support
Thermal Monitor support
Fan Control
Fan status monitoring with rmware 4-pin fan speed con trol via IPMI interface
Low noise fan speed control
System Management PECI (Platform Environment Conguration Interface) 2.0
support
UID (Unit Identication)/Remote UID
System resource alert via SuperDoctor
SuperDoctor
Chassis Intrusion header and detection
BIOS ash upgrade utility
Dimensions WIO form factor: 8" x 13" (203.2mm x 330.2mm)
®
SPI Flash BIOS
®
5, Watch Dog, NMI
®
5
1-8
RJ45
BMC Boot Flash
RJ45
LAN1
RJ45
LAN2
RTL8211E-VB-CG
DDR3
BIOS
VGA CONN
LAN3
X10SRW-F Block Diagram
1-6
1-5
1-4
1-3
1-2
1-1
DDRIV
PCI-E X16
PCI-E X16
PCI-E X8
LAN
I350
RGRMII
SPI
SPI
Temp Sensor
EMC1402-1 *2 at diff SMBUS
BMC
AST2400
COM1
Connector
1-8
1-7
PCI-E X16 G3
PCI-E X16G3
PCI-E X8 G3
RMII/NCSI
CHA,B
CHC,D
PCI-E X1 G2
USB 2.0
SPI
COM2
Header
LPC
PE3 PE1
PCI-E X4
VR12.5
5 PHASE
145W
SNB CORE
DDR-IV
PE2
PCI-E X4 (#5..8)
#2
#1
#4
#3
P13 USB2.0
TPM HEADER
Debug Card
FRONT PANEL
PCH
Chapter 1: Introduction
P0
P1
DMI2
DMI2
4GB/s
0
6.0 Gb/S
USB 2.0
P0-P12
(P7-P10,P12
FOR USB3)
USB 3.0
P1-P4 & P6
SPI
BIOS
HEADER
SYSTEM POWER
FAN SPEED
CTRL
9
8
7
6
5
4
3
2
1
SATA
USB
USB
System Block Diagram
Note: This is a general block diagram and may not exactly represent
the features on your motherboard. See the Motherboard Features
pages for the actual specications of each motherboard.
1-9
X10SRW-F User’s Manual
1-2 Chipset Overview
The X10SRW-F supports a single Intel® E5-2600/1600 Series Processor in an
LGA2011 R3 socket. Built upon the functionality and the capability of the Intel®
C612 Express chipset, the motherboard provides substantial enhancement to
system performance and storage capability for high performance platforms in a
sleek package.
The high-speed Direct Media Interface (DMI) featured in the Intel® C612 Express
chipset supports high-speed Direct Media Interface (DMI) for chip-to-chip true
isochronous communication, providing up to 5 GT/s of software-transparent data
transfer rate on each read/write direction. In addition, the X10SRW-F also features
a TCO timer which allows the system to recover from a software/hardware lock
and perform tasks, including Function Disable and Intruder Detect.
Intel C612 Express Chipset Features
• Direct Media Interface (up 5 GT/s transfer, Full Duplex)
• Dual NAND Interface
• Intel I/O Virtualization (VT-d) Support
• Intel Trusted Execution Technology Support
• PCI Express 2.0 Interface (up to 5.0 GT/s)
• SATA Controller (up to 6Gb/sec)
• Advanced Host Controller Interface (AHCI)
Note: Both E5-2600v4 and E5-1600v4 require Revision 2.0 BIOS (or
higher).
1-10
Chapter 1: Introduction
1-3 Special Features
Recovery from AC Power Loss
Basic I/O System (BIOS) provides a setting for you to determine how the system will
respond when AC power is lost and then restored to the system. You can choose
for the system to remain powered off, (in which case you must press the power
switch to turn it back on), or for it to automatically return to a power-on state. See
the Advanced BIOS Setup section to change this setting. The default setting is
Last State.
1-4 PC Health Monitoring
This section describes the PC health monitoring features of the board. All have
an onboard System Hardware Monitoring chip that supports PC health monitoring.
An onboard voltage monitor will scan these onboard voltages continuously: CPU
Vcore, 12V, 5V, 5VSB, 3.3V, 3.3VSB, Memory, PCH, BMC and Battery voltages.
Once a voltage becomes unstable, a warning is given, or an error message is sent
to the screen. The user can adjust the voltage thresholds to dene the sensitivity
of the voltage monitor.
Environmental Temperature Control
The thermal control sensor monitors the CPU temperature in real time and will turn
on the thermal control fan whenever the CPU temperature exceeds a user-dened
threshold. The overheat circuitry runs independently from the CPU. Once the ther-
mal sensor detects that the CPU temperature is too high, it will automatically turn
on the thermal fans to prevent the CPU from overheating. The onboard chassis
thermal circuitry can monitor the overall system temperature and alert the user when
the chassis temperature is too high.
Note: To avoid possible system overheating, please be sure to provide
adequate airow to your system.
System Resource Alert
This feature is available when the system is used with SuperDoctor® 5 in the
Windows OS environment or used with SuperDoctor II in Linux. SuperDoctor
is used to notify the user of certain system events. For example, you can also
congure SuperDoctor to provide you with warnings when the system temperature,
CPU temperatures, voltages and fan speeds go beyond predened thresholds.
1-11
X10SRW-F User’s Manual
1-5 ACPI Features
ACPI stands for Advanced Conguration and Power Interface. The ACPI specica-
tion denes a exible and abstract hardware interface that provides a standard
way to integrate power management features throughout a PC system, including
its hardware, operating system and application software. This enables the system
to automatically turn on and off peripherals such as CD-ROMs, network cards, hard
disk drives and printers.
In addition to enabling operating system-directed power management, ACPI also
provides a generic system event mechanism for Plug and Play, and an operating
system-independent interface for conguration control. ACPI leverages the Plug and
Play BIOS data structures, while providing a processor architecture-independent
implementation that is compatible with Windows 7, Windows 8, and Windows 2008
Operating Systems.
Slow Blinking LED for Suspend-State Indicator
When the CPU goes into a suspend state, the chassis power LED will start to blink
to indicate that the CPU is in suspend mode. When the user presses any key, the
CPU will "wake up", and the LED will automatically stop blinking and remain on.
1-6 Power Supply
As with all computer products, a stable power source is necessary for proper and
reliable operation. It is even more important for processors that have high CPU
clock rates.
This motherboard accommodates 24-pin ATX power supplies. Although most
power supplies generally meet the specications required by the CPU, some are
inadequate. In addition, the 12V 8-pin power connector located at JPWR1 is also
required to ensure adequate power supply to the system.
Warning: To avoid damaging the power supply or motherboard, please use a power
supply that contains a 24-pin and an 8-pin power connectors. Be sure to connect the
24-pin (J24) and the 8-pin (JPWR1) power connectors on the motherboard to the
power supply. Failure in doing so will void the manufacturer warranty on your power
supply and motherboard.
It is strongly recommended that you use a high quality power supply that meets ATX
power supply Specication 2.02 or above. It must also be SSI compliant. (For more
information, please refer to the web site at http://www.ssiforum.org/). Additionally, in
areas where noisy power transmission is present, you may choose to install a line lter
to shield the computer from noise. It is recommended that you also install a power
surge protector to help avoid problems caused by power surges.
1-12
Chapter 1: Introduction
1-7 Super I/O
The Super I/O supports two high-speed, 16550 compatible serial communication
ports (UARTs). Each UART includes a 16-byte send/receive FIFO, a programmable
baud rate generator, complete modem control capability and a processor interrupt
system. Both UARTs provide legacy speed with baud rate of up to 115.2 Kbps
as well as an advanced speed with baud rates of 250 K, 500 K, or 1 Mb/s, which
support higher speed modems.
The Super I/O provides functions that comply with ACPI (Advanced Conguration
and Power Interface), which includes support of legacy and ACPI power manage-
ment through an SMI or SCI function pin. It also features auto power management
to reduce power consumption.
1-13
X10SRW-F User’s Manual
Notes
1-14
Chapter 2: Installation
Chapter 2
Installation
2-1 Standardized Warning Statements
The following statements are industry-standard warnings, provided to warn the user
of situations which have the potential for bodily injury. Should you have questions or
experience difculty, contact Supermicro's Technical Support department for assis-
tance. Only certied technicians should attempt to install or congure components.
Read this section in its entirety before installing or conguring components in the
Supermicro chassis.
Battery Handling
Warning!
There is a danger of explosion if the battery is replaced incorrectly. Replace the
battery only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer's instructions
電池の取り扱い
電池交換が正しく行われなかった場合、破裂の危険性があります。 交換する電池はメー
カーが推奨する型、または同等のものを使用下さい。 使用済電池は製造元の指示に従
って処 分して下さい。
警告
电池更换不当会有爆炸危险。请只使用同类电池或制造商推荐的功能相当的电池更
换原有电池。请按制造商的说明处理废旧电池。
警告
電池更換不當會有爆炸危險。請使用製造商建議之相同或功能相當的電池更換原有
電池。請按照製造商的說明指示處理廢棄舊電池。
Warnung
Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die
Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp.
Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
2-1
X10SRW-F User’s Manual
Attention
Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer
que par une pile de type semblable ou équivalent, recommandée par le fabricant.
Jeter les piles usagées conformément aux instructions du fabricant.
¡Advertencia!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Re-
emplazar la batería exclusivamente con el mismo tipo o el equivalente recomen-
dado por el fabricante. Desechar las baterías gastadas según las instrucciones
del fabricante.
!הרהזא
תנכס תמייק ץוציפ .הניקת אל ךרדב הפלחוהו הדימב הללוסה לש ףילחהל שי
גוסב הללוסה תא מ םאותה תרבח למומ ןרצי תצ .
תוללוסה קוליס תושמושמה עצבל שי .ןרציה תוארוה יפל
경고!
배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일
하거나 제조사에서 권장하는 동등한 종류의 배터리로만 교체해야 합니다. 제조사
의 안내에 따라 사용된 배터리를 처리하여 주십시오.
Waarschuwing
Er is ontplofngsgevaar indien de batterij verkeerd vervangen wordt. Vervang de
batterij slechts met hetzelfde of een equivalent type die door de fabrikant aan-
bevolen wordt. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften
afgevoerd te worden.
2-2
Chapter 2: Installation
Product Disposal
Warning!
Ultimate disposal of this product should be handled according to all national laws
and regulations.
製品の廃棄
この製品を廃棄処分する場合、国の関係する全ての法律・条例に従い処理する必要が
ありま す。
警告
本产品的废弃处理应根据所有国家的法律和规章进行。
警告
本產品的廢棄處理應根據所有國家的法律和規章進行。
Warnung
Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen
des Landes erfolgen.
¡Advertencia!
Al deshacerse por completo de este producto debe seguir todas las leyes y regla-
mentos nacionales.
Attention
La mise au rebut ou le recyclage de ce produit sont généralement soumis à des
lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de
l'organisme compétent.
רצומה קוליס
!הרהזא
ו תויחנהל םאתהב תויהל בייח הז רצומ לש יפוס קוליס .הנידמה יקוח
2-3
X10SRW-F User’s Manual
경고!
이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다.
Waarschuwing
De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming
met alle nationale wetten en reglementen.
2-2 Static-Sensitive Devices
Electrostatic-Discharge (ESD) can damage electronic com ponents. To avoid dam-
aging your system board, it is important to handle it very carefully. The following
measures are generally sufcient to protect your equipment from ESD.
Precautions
• Use a grounded wrist strap designed to prevent static discharge.
• Touch a grounded metal object before removing the board from the antistatic
bag.
• Handle the board by its edges only; do not touch its components, peripheral
chips, memory modules or gold contacts.
• When handling chips or modules, avoid touching their pins.
• Put the motherboard and peripherals back into their antistatic bags when not in
use.
• For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the motherboard.
• Use only the correct type of onboard CMOS battery. Do not install the onboard
battery upside down to avoid possible explosion.
Unpacking
The motherboard is shipped in antistatic packaging to avoid static damage. When
unpacking the board, make sure that the person handling it is static protected.
2-4