REVEAL™ FREE STANDING SERVICE REFRIGERATED MERCHANDISERS
> REAR SLIDING DOORS > SELF-CONTAINED OR REMOTE UNITS
> CAUTION! DO NOT PUSH OR PULL ON UPPER GLASS ENCLOSURE!
> ONLY USE HANDLES (AT EACH END OF CASE) TO PUSH OR PULL CASE INTO POSITION!
> SEE PAGE 3 FOR THIS OPERATING MANUAL’S MODEL APPLICABILITY AND DIMENSIONS
> SEE PAGE 8 FOR FRONT PANEL, SIDE CLADDING, AIR INTAKE GRILLE & FRONT TOE-KICK
ATTACHMENT INSTRUCTIONS
Models Are Shipped WITHOUT Panels
and Cladding Attached. See Page 8 For
Component Attachment Instructions.
Model NR3655RSV Free Standing Unit Shown
Before Front/Side Cladding and Toe-Kick
Have Been Attached
Structural Concepts Corporation · 888 E. Porter Road · Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 · www.structuralconcepts.com
I:\Manuals\Reveal_Free Standing_Refrig Service Cases 20-80692.pub
Model NR3655RSV Free Standing Unit
Shown After Front/Side Cladding and
Toe-Kick Have Been Attached
Rev A Date: 6.13.2017
TABLE OF CONTENTS
TABLE OF CONTENTS …………………………………………………………………………………...…...
REVEAL™ FREE STANDING REFRIGERATED SERVICE MODEL APPLICABILITY &
DIMENSIONS ……………………………………………………………………………………….…..
OVERVIEW / DISPLAY TYPE I vs. II / COMPLIANCE / WARNINGS / PRECAUTIONS ……………...
INSTALLATION: TOE-KICK & AIR INTAKE GRILLE REMOVAL / DISCONNECTING CA SE FROM
PALLET ...…...………………………………………………………………………………….……….
INSTALLATION, CONT’D.: CASTER ADJUSTMENT / LOCK / UNLOCK / CA SE REMOVAL
FROM PALLET .………………………………………………………………………………...……...
INSTALLATION, CONT’D: REMOVE SHIPPING BRACE AND HANDL ES / ATTACH
COMPONENTS (CLADDING, FRONT TOE-KICK, FRONT PANEL, GRILLE, ETC.) ..……….
INSTALLATION, CONT’D: BRACKET RETAINERS / SHELVING ASSEMBLY COMPONENTS ...…
INSTALLATION, CONT’D: PLUG IN UNIT / MAIN POWER SWITCH ...……………………………..….
CASE DESIGN: FRONT VIEW OF FREE STANDING, SERVICE MERCHANDISERS .......................
CASE DESIGN: REAR VIEW OF FREE STANDING, SERVICE MERCHANDISERS …..…………….
CASE DESIGN, CONT’D: CONTROLLER / DC DRIVERS / MAIN POWER SWITCH /
CONDENSER COIL FILTER ….………………………………………………………………………
CASE DESIGN, CONT’D: TUB AREA (AFTER DECK PAN REMOVAL) ……………………………….
CASE DESIGN, CONT’D: LED LIGHTS / LED LIGHT SWITCH / THERMOMETER ………………….
CASE DESIGN, CONT’D: REAR SLIDING DOOR REMOVAL / REPLACEMENT ……….……………
CASE DESIGN, CONT’D: CONDENSER PACKAGE (SELF-CONTAINED UNITS ONLY) …………..
CLEANING SCHEDULE (TO BE PERFORMED BY STORE PERSONNEL) ..…....…...…………...….
PREVENTIVE MAINTENANCE (TO BE PERFORMED BY TRAINED SERVICE PROVIDER) ……....
TROUBLESHOOTING (TO BE PERFORMED BY STORE PERSONNEL ONLY) ...………………......
TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY) ……….
TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY) CONDENSING SYSTEM ..………………………………………………………………………...….
TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY) EVAPORATOR SYSTEM ...…………………………………………………………………………...
SERIAL LABEL INFORMATION & LOCATION ..…………………………….……...…....……………..…
TEMPERATURE CONTROLLER - CAREL® ...…..……………………..…….……………………..……..
TECHNICAL SERVICE CONTACT INFORMATION & WARRANTY INFORMATION ...…...…...….....
2
3
4-5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20-21
22-23
24-26
27
28
29
30-32
33
2
REVEAL™ FREE STANDING REFRIGERATED SERVICE MODEL APPLICABILITY & DIMS.
Model
Upper Display
Case Height
Overall Case Height Case Depth x Width
NR3633RSV 13 5/8” 32 7/8” 33”D* x 35 3/4”W
NR3640RSV 20 3/8” 39 5/8” 33”D* x 35 3/4”W
NR3647RSV 27 7/8” 47 1/8” 33”D* x 35 3/4”W
NR3655RSV 35 1/4” 54 5/8” 33”D* x 35 3/4”W
NR4833RSV 13 5/8” 32 7/8 33”D* x 47 3/4”W
NR4840RSV 20 3/8” 39 5/8” 33”D* x 47 3/4”W
NR4847RSV 27 7/8” 47 1/8” 33”D* x 47 3/4”W
NR4855RSV 35 1/4” 54 5/8” 33”D* x 47 3/4”W
3
OVERVIEW / DISPLAY TYPE I vs. II / COMPLIANCE / WARNINGS / PRECAUTIONS - PAGE 1 of 2
OVERVIEW
These Structural Concepts Reveal™ cases are
designed to merchandise packaged products at 40°F
(4 °C) or less product temperatures.
Cases should be installed and operated according to
this operating manual’s instructions to insure proper
performance. Improper use will void warranty.
TYPE I vs. TYPE II ENVIRONMENTAL CONDITIONS
This unit is designed for the display of products in
ambient store conditions where temperature and
humidity are maintained within a specific range.
Type I display refrigerators are intended for use in an
area where environmental conditions are controlled
and maintained so that the ambient temperature does
not exceed 75 °F (24 °C) and 55% maximum humidity.
Type II display refrigerators are intended for use in an
area where environmental conditions are controlled
This equipment MUST be installed in compliance with
all applicable NEC, federal, state and local
ATTENTION
CONTRACTORS
and maintained so that the ambient temperature does not
exceed 80 °F (27 °C) and 55% maximum humidity.
If unsure if your unit is Type I or II, see tag next to serial
label. See SERIAL LABEL LOCATION & INFORMATION LISTED / TECH INFO & SERVICE
section in this manual for sample serial labels.
COMPLIANCE
Performance issues when in violation of applicable
NEC, federal, state and local electrical and plumbing
codes are not covered by warranty.
See below compliance guideline.
WARNINGS
Please read the important warnings in this document
carefully as they can prevent injury or death.
See next page for PRECAUTIONS.
COMPLIANCE
electrical and plumbing codes.
WARNING
ELECTRICAL
HAZARD
WARNING
KEEP
HANDS
CLEAR
WARNING
Risk of electric shock. Disconnect power before servicing unit.
CAUTION! More than one source of electrical supply is
employed with units that have separate circuits.
Disconnect ALL ELECTRICAL SOURCES before servicing.
WARNING
Hazardous moving parts. Do not operate unit with covers removed.
Fan blades may be exposed when deck panel is removed.
Disconnect power before removing deck panel.
CAUTION! IF YOUR UNIT IS SELF-CONTAINED, YOU MUST
CHECK CONDENSATE PAN POSITION & PLUG!
Water on flooring can cause extensive damage!
Before powering up unit, check and confirm that:
Condensate pan is DIRECTLY UNDER condensate drain.
Condensate pan plug is securely plugged into receptacle.
Overflow pan has plug connected to its box. Units with
optional Clean Sweep® MUST HAVE two plugs connected.
4
OVERVIEW / DISPLAY TYPE I vs. II / COMPLIANCE / WARNINGS / PRECAUTIONS - PAGE 2 of 2
PRECAUTIONS
Following are important precautions to prevent
damage to unit or merchandise.
Please read carefully!
CAUTION! LAMP REPLACEMENT GUIDELINES
CAUTION
LED lamps reflect specific size, shape and overall design.
Any replacements must meet factory specifications.
CAUTION! GFCI BREAKER USE REQUIREMENT
If N.E.C. (National Electric Code) or your local code