33” and 35” DEEP SERVICE REFRIGERATED DISPLAY CASES
PLEASE NOTE THE FOLLOWING:
1. YOUR SPECIFIC MODEL NUMBER IS ON THE SERIAL LABEL ON CASE REAR (NEAR MAIN POWER SWITCH).
2. SEE “MODELS (AND THEIR RESPECTIVE CASE DIMENSIONS) LISTED IN THIS MANUAL” SECTION FOR
ADDITIONAL INFORMATION REGARDING SPECIFIC CASE DIMENSIONS OF STANDARD MODELS AND
PN 55009
CDRs.
(HMG2642R.4439)
[35” Deep Model]
HMG3953R
(HMG3953R)
[33” Deep Model]
(HMG7553R)
HMG7553R
[33” Deep Model]
(HMG2653R)
HMG2653R
[33” Deep Model]
Structural Concepts Corporation · 888 E. Porter Road · Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 · www.structuralconcepts.com
TABLE OF CONTENTS ……………………………………………………………………………………...
MODELS LISTED IN MANUAL (AND DETERMINING THEIR RESPECTIVE CASE DIMENSIONS)
OVERVIEW AND WARNINGS ……………..…….…………………………..………………………...…..
RAISING THE CURVED GLASS / OPENING REAR DOOR / REMOVING REAR DOORS ………...
DRAIN, HOSE AND BRACKET PLACEMENT ILLUSTRATIONS …………..…………..……….……..
MAINTENANCE FUNDAMENTALS - STANDARD LIGHT FIXTURES ...…………..……..…….…......
MAINTENANCE: REFRIGERATION PKG., TEMP. CONTROLLER, EVAPORATOR PAN ACCESS
CLEANING SCHEDULE - TO BE PERFORMED BY STORE PERSONNEL ………………………….
TROUBLESHOOTING - GENERAL ISSUES ………………………………………..…………...……….
TROUBLESHOOTING - CONDENSING SYSTEM ………………………………..……………..…..…..
TROUBLESHOOTING - EVAPORATOR SYSTEM ………………………………..……………..……...
PREVENTIVE MAINTENANCE (TO BE PERFORMED BY TRAINED SERVICE PROVIDER) ….....
SERIAL LABEL INFORMATION & LOCATION ..……………………………………...…....…………..…
TEMPERATURE CONTROLLER - CAREL® ...…. ……………………..……..…………………...……..
TECHNICAL SERVICE CONTACT INFORMATION & WARRANTY INFORMATION ...……….….....
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16-18
19
20
21
22
23-25
26
2
MODELS LISTED IN THIS MANUAL (AND DETERMINING THEIR RESPECTIVE CASE DIMENSIONS)
DETERMINING YOUR MODEL AND ITS CASE DIMENSIONS:
Note 1. Your model number can be found on serial label at rear of case (near main power switch).
Note 2. Dimensions of most models can be found at www.structuralconcepts.com. Simply enter
the case model number into the Product Number Search box. Click the product specification
link for complete dimensions.
Note 3. If your specific model is not found, contact technical service (phone number is listed at
Technical Service section in this manual) for dimensions.
Note 4. CDRs (Customer Design Requests) are listed with a 4-digit number. All CDR dimensions
are identical to standard model dimensions.
THIS OPERATING MANUAL ENCOMPASSES THE FOLLOWING MODELS (AND THEIR
RESPECTIVE CDRs):
Model HMG2653R
Model HMG3953R
Model HMG5153R
Model HMG6353R
Model HMG7553R
(33” Deep Models)
Model HMG2642R.4439
(35” Deep Model)
OVERVIEW AND WARNINGS
OVERVIEW
• These Structural Concepts Harmony® service cases are designed to merchandise packaged products
at 41°F or less product temperatures.
• These cases should be installed and operated according to this operating manual’s instructions to
insure proper performance. Improper use will void warranty.
This unit is designed for the display of products in ambient store conditions where temperatures and
humidity are maintained within a specific range.
• For NSF® Type 1 Conditions (most cases): ambient conditions are to be at 55% max. humidity / 75°F.
• For NSF® Type 2 Conditions: ambient conditions are to be at 60% maximum humidity / 80°F.
• If unsure if your case is Type 1 or Type 2, contact Structural Concepts Technical Service (see
Technical Service section in this manual for phone number).
Caution: Do not allow air conditioning, electric fans, open doors or windows to create air currents
around display case as this may detrimentally affect proper case temperatures and operation.
ATTENTION INSTALLER
This equipment must be installed in compliance with all
applicable NEC, federal, state and local plumbing codes.
WARNING
ELECTRICAL
HAZARD
WARNING
ELECTRICAL
HAZARD
WARNING
KEEP HANDS
CLEAR
WARNING
HOT
SURFACE
WARNING
Risk of electric shock.
Disconnect power before servicing unit
WARNING
More than one source of electrical supply is employed
with units that have separate circuits.
Disconnect all sources before servicing.
WARNING
Hazardous moving parts. Do not operate unit with covers removed.
Fan blades may be exposed when deck panel is removed.
Disconnect power before removing deck panel.
WARNING
Evaporator Pan is Hot! Disconnect and allow to cool
before cleaning or removing from case.
CAUTION
CAUTION
Lamps have been treated to resist breakage
and must be replaced with similarly treated lamps.
4
INSTALLATION: SKID REMOVAL, ADJUSTABLE FRONT TOE-KICK / REMOVABLE FRONT GRILLE
1. Remove Case From Skid (Levelers)
• Remove shipping brace that may be
securing case to skid.
• Support case to prevent tipping.
• Caution! Levelers can be damaged if case
hits floor with heavy force!
• Carefully slide unit to
rear of skid and tip
backward off skid.
• Illustration may not
2. Remove Case From Skid (Casters)
Remove shipping brackets that may be securing
casters to skid
• Place ramp up against skid (to allow case to
smoothly slide off from skid).
• Maintain support of case at all times or center
of gravity may cause case to fall.
• Unlock Casters. Roll unit to rear of skid.
Roll down ramp
and off from skid.
reflect every feature
or option of your
particular case.
Note: Illustrations
shown reflect a
general outline of
Slide Skid Out
sample cases and do
not reflect features or
options of your
Case can be repositioned with pallet truck when
front lower panel is removed. Blocking may be
necessary to obtain adequate height.
3. Adjustable Front Toe-Kick / Removable Front Grille
• Front toe-kick is adjustable. Simply loosen screws (one at each end) and adjust accordingly.
To remove front grille, remove screws located at underside of front panel. This will allow access to
•
drain line or refrigeration lines.
Front Grille will fall forward and can be lifted up and away from case.
•
Replace Front Grille in reverse order it was removed from case.
•
• Note: Illustration below may not reflect every feature or option of your particular case.