PRODUCT SPECIFICATIONS
PLAN VIEW SIDE VIEW
22 3/8"
15 5/8"
36 5/8"
1 1 /2"
12 1/4"
81"
88"
5"
8 1/2"
8 1/2"
6 7/8"
9 1/2"
TYP.
15 5/8"
15 5/8"
15 5/8"
3 3/8"
1 3/4"
7 1/2"
1 7/8"
*SELF-CONTAINED MODELS CO3678R & CO4778R
SERVICE ACCESS AREAS ONLY ACCESSIBLE
BY PULLING OUT COMPRESSOR UNIT
TOE-KICK
NOTE: CO3678R - (X) = 30" - (1) DOOR, SERVICE SIDE LH HINGE STD (RH HINGE OPT)
CO4778R - (X) = 19" - (2) DOORS RH & LH HINGED
CO5978R - (X) = 19 5/8" - (2) DOORS RH & LH HINGED
CO7178R - (X) = 30" - (2) DOORS RH & LH HINGED
REMOVABLE
REAR WALL
SPACERS
OPEN AREA
REQUIRED
AIR FLOW
CASE
FRONT
REAR DOOR
OPTION
ROLLER DOOR
OPTION ADDS
7" TO HEIGHT
REMOVABLE
REAR WALL
SPACERS
REAR SWING
DOOR, SEE NOTE
OPTIONAL
ELECTRICAL ACCESS
5 1/2" SERVICE ACCESS
AREA FOR C07178R
SELF-CONTAINED*
1 1/4"
D1
9" SERVICE ACCESS
AREA FOR CO5978R
SELF-CONTAINED*
L2
25 3/4"
14 3/4"
3 3/8"
1"
TYP.
2"
TYP.
"X"
L1
.
2"
15 1/2"
27" TO TOE-KICK
12"
8 3/4"
8 1/2"
36 3/8"
17 1/8"
NOTE: ALL DIMENSIONS APPROXIMATE
ELECTRICAL JUNCTION BOX
(SUPPLIED WITH 6" LEADS OR POWER CORD).
LOCATION OF CONDENSATE DRAIN TUBE
(SUPPLIED WITH
3
4
" OR 1
1
2
" PVC DRAIN TUBE).
DRY CASE SERVICE ACCESS AREA.
SELF-CONTAINED CASE SERVICE ACCESS AREA.
REMOTE CASE SERVICE ACCESS AREA.
REFRIGERATION LINE CONNECTION.
Intended Use of Display Area: Packaged refrigerated products
Integrated Product Temperature (IPT): 41°F
Intended Environment: Designed to operate in ambient conditions of 75°F / 55% relative humidity.
Important Note:
1) 40 1/4" Minumum entry door clearence required (w/out shipping
skid) 2) Performance issues (product temperatures, water on floor,
etc.) caused by adverse conditions are not covered by warranty. 3)
Keep unit at least 15’ from exterior doors, overhead HVAC vents, or
any air curtain disruption. 4) End panels must be tightly joined
or kept at least 6” away from any structure to prevent condensation.
5) Do not expose unit to direct sunlight or any heat source (ovens,
fryers, etc.). 6) Keep at least 8” of clearance above unit for air
discharge (self-contained only).
Model L1* L2* Volts++ Amps NEMA Plug Volts++ Amps*** BTUH Ship Wt Frt Cls
CO3678R 960 11036 1/4 5 1/8 5300120/1/60 NEMA 5-20P15.12 120/1/60 2.11
Self-Contained Refrigeration/Dry Remote Refrigeration w/Leads
CO4778R 1150 11047 1/4 11 8000220/1/60** NEMA 14-20P10.845 120/1/60 2.11
CO5978R 1350 11059 1/4 22 1/2 9350220/1/60** NEMA 14-20P10.785 120/1/60 2.05
CO7178R 1550 11071 1/4 18 1/2 11050220/1/60** NEMA 14-20P15.045 120/1/60 3.94
++ Operating range for 120 volt rating is 110-120 volts; operating range for 220 volt rating is 208-230 volts.
** Requires 3 wires + ground
*** Does not include electric defrost on freezer models
REGULATORY APPROVALS
ETL Listed Certified to CAN/CSA 22.2
ETL Listed Conforms to UL 471
ETL Sanitation Conforms to NSF 7
REV: M - 2/17/2012
Note: Information is subject to change at any time.
888 E. Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com