Structural Concepts CO3660R User Manual

PRODUCT SPECIFICATIONS
PLAN VIEW SIDE VIEW
NOTE: ALL DIMENSIONS APPROXIMATE
LOCATION OF CONDENSATE DRAIN TUBE (SUPPLIED WITH
3
4
" OR 1
1
2
" PVC DRAIN TUBE).
DRY CASE SERVICE ACCESS AREA.
SELF-CONTAINED CASE SERVICE ACCESS AREA.
REMOTE CASE SERVICE ACCESS AREA.
REFRIGERATION LINE CONNECTION.
1 7/8"
6"
1 1/2"
REAR DOOR OPTION
NOTE: CO3660R - (X) = 30" - (1) DOOR, SERVICE SIDE LH HINGE STD (RH HINGE OPT) CO4760R - (X) = 19" - (2) DOORS RH & LH HINGED CO5960R - (X) = 19 5/8" - (2) DOORS RH & LH HINGED CO7160R - (X) = 30" - (2) DOORS RH & LH HINGED
REAR SWING DOOR, SEE NOTE
REMOVABLE REAR WALL SPACERS
9" SERVICE ACCESS AREA FOR CO5978R
SELF-CONTAINED
REMOVABLE
REAR WALL
SPACERS
*SELF-CONTAINED MODELS CO3660R & CO4760R
SERVICE ACCESS AREAS ONLY ACCESSIBLE
BY PULLING OUT COMPRESSOR UNIT
CASE FRONT
L1
3 3/8"
D1
1"
TYP.
34 3/4"
L2
14 3/4"
TOE-KICK
18 1/8"
1 1/4"
8"
8"
9 5/8"
OPEN AREA
REQUIRED
( AIR FLOW)
12"
22 3/8"
15 5/8"
15 5/8"
CASE
FRONT
8 1/4"
12 1/4"
27" TO TOE-KICK
63 1/8"
9 1/2"
TYP.
21" SERVICE ACCESS
AREA FOR CO7160R
SELF CONTAINED
25 3/4"
2"
17 1/8"
33 1/8"
1 1/4"
3 3/8"
25 3/4"
2"
TYP.
70 1/8"
ROLLER DOOR
OPTION ADDS
7" TO HEIGHT
Intended Use of Display Area: Packaged refrigerated products Integrated Product Temperature (IPT): 41°F Intended Environment: Designed to operate in ambient conditions of 75°F / 55% relative humidity.
Model L1* L2* Volts++ Amps NEMA Plug Volts++ Amps*** BTUH Ship Wt Frt Cls CO3660R 800 11036 1/4 5 1/8 3970120/1/60 NEMA 5-20P14.6 120/1/60 1.59
Self-Contained Refrigeration/Dry Remote Refrigeration w/Leads
CO4760R 1100 11047 1/4 11 4017120/1/60 NEMA 5-20 P12.9 120/1/60 1.59 CO5960R 1150 11059 1/4 22 1/2 4725120/1/60 NEMA 5-20P15.25 120/1/60 1.44
Important Note:
1) 40 1/4" Minumum entry door clearence required (w/out shipping skid) 2) Performance issues (product temperatures, water on floor, etc.) caused by adverse conditions are not covered by warranty. 3) Keep unit at least 15’ from exterior doors, overhead HVAC vents, or any air curtain disruption. 4) End panels must be tightly joined or kept at least 6” away from any structure to prevent condensation.
5) Do not expose unit to direct sunlight or any heat source (ovens, fryers, etc.). 6) Keep at least 8” of clearance above unit for air discharge (self-contained only).
CO7160R 1200 11071 1/4 18 1/2 5450220/1/60** NEMA 14-20P9.795 120/1/60 2.28
++ Operating range for 120 volt rating is 110-120 volts; operating range for 220 volt rating is 208-230 volts. ** Requires 3 wires + ground *** Does not include electric defrost on freezer models
REGULATORY APPROVALS
ETL Listed Certified to CAN/CSA 22.2 ETL Listed Conforms to UL 471 ETL Sanitation Conforms to NSF 7
REV: H - 2/20/2012
Note: Information is subject to change at any time. 888 E. Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com
Printed: 2/27/2012 2:04:35 PM
Loading...