16.8 Details on energy consumption ������������������������������ 14
16.9 Data table �������������������������������������������������������� 14
GUARANTEE
ENVIRONMENT AND RECYCLING
2 | SHZ S (GB) www.stiebel-eltron.com
SPECIAL INFORMATION | OPERATION
General information
SPECIAL INFORMATION
- The appliance may be used by children aged8
and older and persons with reduced physical,
sensory or mental capabilities or a lack of experience and know-how, provided that they are
supervised or they have been instructed on how
to use the appliance safely and have understood
the resulting risks. Children must never play with
the appliance. Children must never clean the appliance or perform user maintenance unless they
are supervised.
- The connection to the power supply is only permissible as a permanent connection in conjunction with the removable cable grommet. Ensure
the appliance can be separated from the power
supply by an isolator that disconnects all poles
with at least 3mm contact separation.
- Observe the maximum permissible pressure (see
chapter Installation/ Specification/ Data table).
- The appliance is pressurised. During the heat-up
process, expansion water will drip from the safety
valve.
- Regularly activate the safety valve to prevent
it from becoming blocked, e.g. by limescale
deposits.
- Drain the appliance as described in chapter „Installation/ Maintenance/ Draining the
appliance“.
- Install a type-tested safety valve in the cold water
supply line. Please note that, depending on the
static pressure, you may also need a pressure reducing valve.
- Size the drain so that water can drain off unimpeded when the safety valve is fully opened.
OPERATION
1. General information
The chapters “Special Information” and “Operation” are intended
for both the user and qualified contractors.
The chapter "Installation" is intended for qualified contractors.
Note
Read these instructions carefully before using the appliance and retain them for future reference.
Pass on the instructions to a new user if required.
1.1 Safety instructions
1.1.1 Structure of safety instructions
KEYWORD Type of risk
!
Here, possible consequences are listed that may result
from failure to observe the safety instructions.
Steps to prevent the risk are listed.
1.1.2 Symbols, type of risk
SymbolType of risk
!
1.1.3 Keywords
KEYWORDMeaning
DANGER Failure to observe this information will result in serious
WARNING Failure to observe this information may result in serious
CAUTION Failure to observe this information may result in non-
Injury
Electrocution
Burns
(burns, scalding)
injury or death.
injury or death.
serious or minor injury.
- Fit the discharge pipe of the safety valve with
a constant downward slope and in a room free
from the risk of frost.
- The safety valve discharge aperture must remain
open to atmosphere.
www.stiebel-eltron.com SHZ S (GB) | 3
OPERATION
Safety
1.2 Other symbols in this documentation
Note
General information is identified by the symbol shown
on the left.
Read these texts carefully.
SymbolMeaning
!
This symbol indicates that you have to do something. The ac-
tion you need to take is described step by step.
Material losses
(appliance, consequential and environmental losses)
Appliance disposal
1.3 Units of measurement
Note
All measurements are given in mm unless stated otherwise.
2. Safety
2.1 Intended use
The appliance is intended for heating domestic hot water and can
supply one or more draw-off points.
This appliance is designed for domestic use. It can be used safely
by untrained persons. The appliance can also be used in a nondomestic environment, e.g. in a small business, as long as it is
used in the same way.
Any other use beyond that described shall be deemed inappropriate. Observation of these instructions and of instructions for any
accessories used is also part of the correct use of this appliance.
2.2 General safety instructions
WARNING Burns
During operation, the tap and safety assembly can reach
temperatures in excess of 60°C.
There is a risk of scalding at outlet temperatures in excess of 43°C.
Note
The appliance is under pressure. During the heat-up process, expansion water will drip from the outlet side of the
safety valve and/ or of the T&P valve. If water continues
to drip when heating is completed, please inform your
qualified contractor.
2.3 CE designation
The CE designation shows that the appliance meets all essential
requirements according to the:
- Electromagnetic Compatibility Directive
- Low Voltage Directive
2.4 Test symbols
See type plate on the appliance.
3. Appliance description
The appliance heats domestic hot water electrically subject to the
connected heating output or with rapid heat-up. You can adjust
the temperature using the temperature selector. Subject to the
power supply, the water is heated automatically to the required
temperature. The currently available heat content is displayed.
The internal steel cylinder is coated with special directly applied
enamel and is equipped with a protective anode. The anode protects the internal cylinder from corrosion.
Dual circuit operation
During off-peak tariff periods (power supply utilities' enable
times), the appliance automatically heats up the water content
subject to the connected heating output and temperature setting.
In addition, you can start the booster heater during peak tariff
periods.
Single circuit operation
In this operating mode, the appliance heats up the water automatically subject to the connected heating output and temperature
setting.
Manual rapid heat-up operation
The appliance heats the water if the rapid heat-up button is
pressed. Once the selected temperature has been reached, the
appliance switches off and does not restart.
WARNING Injury
!
The appliance may be used by children aged 8 and up
and persons with reduced physical, sensory or mental
capabilities or a lack of experience provided that they
are supervised or they have been instructed on how to
use the appliance safely and have understood the resulting risks. Children must never play with the appliance.
Children must never clean the appliance or perform user
maintenance unless they are supervised.
Material losses
!
Protect the water lines and the safety assembly against
frost.
4 | SHZ S (GB) www.stiebel-eltron.com
3.1 Frost protection
The appliance is also protected against frost on the temperature
setting "cold" subject to it being switched 'live'. The appliance
switches on in good time and heats the water. The water supply
lines and the safety assembly are not protected against frost by
the appliance. You can use the appliance in single circuit, dual
circuit or manual rapid heat-up operation.
OPERATION
Settings
4. Settings
The temperature can be freely adjusted.
5
4
3
1 ON/OFF indicator
2 Heat content indicator
3 Rapid heat-up key
4 Temperature selector
5 SERVICE ANODE indicator
• Cold
E Recommended energy saving position, low scaling, 60°C
70°C Maximum temperature setting
Depending upon the system, the actual temperatures may vary
from the set value.
Material losses
!
Notify your qualified contractor if the SERVICE
ANODE indicator illuminates.
1
2
ON/OFF indicator
The ON/OFF indicator illuminates in single circuit and manual
rapid heat-up operation while the water is heated, in dual circuit
operation, it only illuminates during rapid heat-up.
Dual circuit operation with rapid heat-up
You can switch on rapid heat-up with the corresponding key. A
remote control can also be installed for this purpose. The rapid
heat-up function stops and will not restart when the selected
temperature has been reached.
Manual rapid heat-up operation
You have to start the appliance with the rapid heat-up key. Once
the selected temperature has been reached, the appliance switches off and does not restart.
26�02�07�0356
5. Cleaning, care and maintenance
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
Check the taps/valves regularly. You can remove limescale
deposits at the spouts using commercially available descaling
agents.
Have the electrical safety of the appliance and the func-
tion of the safety assembly regularly checked by a qualified
contractor.
The protective anode must be replaced by the qualified
contractor as soon as the SERVICE ANODE indicator illuminates (see chapter "Maintenance / Replacing the protective
anode").
Heat content indicator
The currently available mixed water volume is displayed at 40°C
with a cold water temperature of 15°C and a temperature setting
of 65°C. The number of lights indicates the minimum available
mixed water volume at 40°C.
This enables you to match the temperature setting to your draw-off
pattern to ensure optimum efficiency and save energy. We recommend you set the temperature initially to 65°C. You can lower the
set temperature if more than one indicator illuminates when your
maximum draw-off volume is reached.
SHZ 30 S (GB)l102030405060
SHZ 50 S (GB)l1330456580100
SHZ 100 S (GB) l256090130160200
SHZ 150 S (GB) l4090135190240295
6. Troubleshooting
FaultCauseRemedy
The water does not heat
up.
The flow rate is low. The aerator in the tap or
SERVICE ANODE indicator
illuminates.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-00000):
There is no power. Check the fuses/MCBs in
shower head is scaled up
or contaminated.
Replace the protective
anode.
your fuse box.
Clean and/or descale the
aerator or shower head.
Notify your qualified
contractor.
Nr.: 000000-0000-000000
Made in Germany
D0000047942
www.stiebel-eltron.com SHZ S (GB) | 5