STIEBEL ELTRON HydroShark 7, HydroShark 10, HydroShark 12, HydroShark 14, HydroShark 19 Operation And Installation Manual

...
OPERATION AND INSTALLATION UTILISATION ET INSTALLATION
Electric Modulating Micro-Boiler
»HydroShark 7 »HydroShark 10 »HydroShark 12 »HydroShark 14 »HydroShark 19 »HydroShark 24 »HydroShark 29 »HydroShark 36
HydroShark 7 - HydroShark 10:
Conforms to ANSI/UL Std. 499 Certifi ed to CAN/CSA Std. E335-1 & E335-2-35
Conforme à la norme ANSI/UL Std. 499 Certifi é à la norme CAN/CSA Std. E335-1 & E335-2-35
HydroShark 12 - HydroShark 36:
Conforms to ANSI/UL Std. 834 Certifi ed to CAN/CSA C22.2 No 64
Conforme à la norme ANSI/UL Std. 834 Certifi é à la norme CAN/CSA C22.2 No 64
HydroShark Electric Boiler (7-36 KW) Installation Manual and Owner’s Guide
HydroShark 12 - HydroShark 36
UL 834
HydroShark 7 - HydroShark 10
UL 499
The
HydroShark Electric Boiler features advanced
technology, impressive energy-saving performance, and a compact design. Exclusively manufactured by Stiebel Eltron, a leader in heating technologies for the past 80 years.
Featuring
• Effi ciency: 100 %
• Wall Hung
Flow Activated: .5 GPM
Copper Heating Vessel
Temperature Range: 86°-140° F*
No Venting Required
Modulation Status LED
Do not return to stores. Dam-
ages or repairs call
Stiebel Eltron 800.805.5384
Models:
HydroShark 7 HydroShark 10 HydroShark 12 HydroShark 14 HydroShark 19 HydroShark 24 HydroShark 29 HydroShark 36
2 | HYDROSHARK WWW.HYDRO-SHARK.COM
If you have any questions,
please call or write to:
17 West St.
West Hatfi eld, MA 01088
CONTENTS
Installation Manual
SPECIFICATIONS..........................................................................................................4
INTRODUCTION............................................................................................................5
MOUNTING THE UNIT...................................................................................................6
INSTALLATION...............................................................................................................7
Electrical Connections.........................................................................................7
Fluid connections.................................................................................................10
Technical Data.....................................................................................................10
Wiring Diagrams...................................................................................................11
APPLICATIONS..............................................................................................................12
OWNER’S GUIDE
TROUBLESHOOTING..................................................................................................15
General...............................................................................................................15
Components Diagram.........................................................................................16
PARTS LIST...................................................................................................................17
PRESSURE DROP TABLE............................................................................................18
IMPORTANT!
BOILERS ARE TO BE USED FOR RADIANT FLOOR HEATING ONLY!**
THIS MANUAL MUST BE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL THE HydroShark BOILERS. IF YOU DO NOT FOLLOW THE SAFETY RULES OR THE INSTRUCTIONS OUTLINED IN THIS MANUAL, THE UNIT MAY NOT OPERATE PROPERLY AND IT COULD CAUSE PROPERTY DAMAGE, SERIOUS BODILY INJURY AND/OR DEATH.
MANUFACTURER WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED IN THIS MANUAL OR BE­CAUSE OF IMPROPER USE. IMPROPER USE INCLUDES THE USE FOR THIS APPLIANCE TO HEAT ANY LIQUID OTHER THAN WATER OR PROPYLENE GLYCOL. FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OR IMPROPER USE VOIDS THE WARRANTY. NEVER REMOVE THE UNITS FRONT COVER UNLESS POWER IS TURNED OFF.
IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OR OPERATION OF THESE BOILER, PLEASE CALL OUR TECHNICAL SERVICE LINE AT 800.805.5384.
**Unless when used with Stiebel Eltron DHW Integrator Panels (Use HydroShark 29 or HydroShark 36 KW Boilers only with Combi Panel Systems, Size boilers accordingly)
WWW.HYDRO-SHARK.COM HYDROSHARK| 3
Installation Manual
CONGRATULATIONS
Congratulations and thank you for choosing our micro boiler. Before use, we
recommend that you read through this installation manual carefully. Keep
this manual for future reference.
If you need an additional manual, contact the manufacturer or your local distributor. When you call, please tell us the product name and the serial
number of your unit written on the rating plate of the boiler.
4 | HYDROSHARK WWW.HYDRO-SHARK.COM
SPECIFICATIONS
HYDROSHARK
AMP
MODEL KW VOLTS WIRE SIZE
HydroShark 7 7
HydroShark 10 10 6 40 (1) 50 32,765
HydroShark 12 12 4 50 (1) 70 40,956
HydroShark 14 14 2 x 8 60 (2) 40 49,147
240
HydroShark 19 19 2 x 6 80 (2) 50 65,526
HydroShark 24 24 2 x 4 100 (2) 70 81,912
HydroShark 29 29 3 x 6 120 (3) 50 98,977
HydroShark 36 36 3 x 4 150 (3) 70 122,868
8 30 (1) 40 24,573
DRAW (MAX)
DBL POLE BREAKER
SIZE
BTU
HydroShark Boiler Temp vs Flow Rate
8 7
6
5 4
with 70 Deg F Return Fluid
____
HydroShark 7
____
HydroShark 10
____
HydroShark 12
____
HydroShark 14
____
HydroShark 19
____
HydroShark 24
____
HydroShark 29
____
HydroShark 36
WATER
TEMP
RANGE
86° - 140° F
3
2
Boiler Flow-GPM
1 0
90 100 110 120 130
WWW.HYDRO-SHARK.COM HYDROSHARK| 5
140
DEG F
INTRODUCTION
IMPORTANT!
Read this entire manual. Failure to follow all the guides, instructions and rules could cause personal injury or property damage. Improper installation, adjustment, alteration, service and use of this unit can result in serious injury.
This unit must be installed by a licensed electrician and plumber. The installation must comply with all national, state and local plumbing and electric codes. Proper installation is the responsibility of the installer. Failure to comply with the installation and operating instructions or improper use voids the warranty.
Save these instructions for future reference. Installer should leave these instructions with the consum­er.
If you have any questions regarding the installation, use or operation of this micro boiler, or if you need any additional installation manuals call Stiebel Eltron at 800.805.5384 or visit us online at www. hydro-shark.com
GENERAL
The output of heat from the boiler is electronically controlled. The boiler will deliver any water tem­perature between 86° F - 140° F. Set the desired water delivery temperature using the knob on the front cover. (Do not exceed temperatures above 130° when using this product with tubing in
concrete)
When the power light is ashing, full element power is being applied. When the power light is not ashing, the element power is being modulated to the water delivery temperature.
Recommend setting for radiant fl oor heating (Tubing in Concrete) is 105° F - 125° F.
Recommended setting for Staple Up (Floor Warming Only) is 130° - 140° F.
Temperature setting and water delivery temperatures may vary depending on fl ow rates. Size boil- er accordingly. See fl ow rate chart for more information.