STIEBEL ELTRON DHC-E 8/10, DHC-E 11 L, DHC-E 12 Operation And Installation

OPERATION AND INSTALLATION OPERACIÓN E INSTALACIÓN UTILISATION ET INSTALLATION
ЭКСПЛУАТАЦИЯ И МОНТАЖ
ELECTRONICALLY CONTROLLED INSTANTANEOUS WATER HEATER | CALENTADOR INSTANTÁNEO CON CONTROLADO ELECTRÓNICA | CHAUFFE-EAU INSTANTANÉ À GESTION ÉLECTRONIQUE |
ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ
The DHC-E series is tested and certifi ed by WQA against NSF/ ANSI 372 for lead free compliance.
STIEBEL ELTRON, Inc.
17 West Street | West Hat fi eld, MA 01088 Tel. 413-247-3380 | Fax 413-247-3369 Email info@stiebel-eltron-usa.com www.stiebel-eltron-usa.com
2 | DHC-E WWW.STIEBEL-ELTRON-USA.COM
CONTENTS | OPERATION
OPERATION
1. General information _________________________________________2
1.1 Safety information _______________________________________________ 2
1.2 Other symbols in this document ______________________________ 3
2. Safety __________________________________________________________3
2.1 Intended use ______________________________________________________ 3
2.2 General Information_____________________________________________ 3
2.3 Safety Precautions _______________________________________________ 3
2.4 Test symbols ______________________________________________________ 3
3. Register your product _______________________________________4
4. General ________________________________________________________4
5. Troubleshooting ______________________________________________4
INSTALLATION
6. Mounting the appliance _____________________________________5
6.1 Application ________________________________________________________ 5
7. Mounting ______________________________________________________5
8. Water connections ___________________________________________6
9. Electrical connection _________________________________________6
9.1 DHC-E 8/10 - Appliance with output power options ______ 6
9.2 DHC-E 11 L _________________________________________________________ 7
9.3 Temperature setting/anti-scalding protection ____________ 7
9.4 Terminal block ____________________________________________________ 7
10. Commissioning _______________________________________________7
10.1 Appliance handover _____________________________________________ 7
11. Troubleshooting ______________________________________________8
11.1 Display options LED diagnostic „traffi c lights“ _____________ 8
11.2 Fault table _________________________________________________________ 8
12. Normal maintenance _________________________________________8
13. Technical Data ________________________________________________8
13.1 Dimensioned drawing __________________________________________ 8
13.2 Wiring diagram __________________________________________________ 9
13.3 Maximum temperature increase above ambient water temperature _____________________________________________________ 10
13.4 Data table ________________________________________________________ 11
14. Spare parts _________________________________________________ 12
15. Warranty ____________________________________________________ 13
OPERATION
1. General information
Note
Read these instructions carefully before using the ap­pliance and familiarize yourself with its functions. Keep these instructions safe. Pass on the instructions to a new user if required.
1.1 Safety information
1.1.1 Structure of safety information
KEYWORD: Type of risk Here, possible consequences are listed that may re­sult from not observing the safety information.
 Steps to prevent the risk are listed.
1.1.2 Symbols. type of risk
Symbol Type of risk
!
Injury
Electrocution
Burns or scalding
1.1.3 Keywords
KEYWORD Description
DANGER If this information is not observed, it will result in serious
injury or death.
WARNING If this information is not observed, it can result in serious
injury or death.
CAUTION If this information is not observed, it can lead to medium
or minor injury.
OPERATION
SAFETY
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM DHC-E | 3
1.2 Other symbols in this document
Note
Notes are bordered by horizontal lines above and below the text. General information is identifi ed by the symbol shown on the left.
 Read these notes carefully.
Symbol
!
Damage to the appliance and environment
Appliance disposal
 This symbol indicates that you have to do something. The ac-
tion you need to take is described step by step.
2. Safety
Observe the following safety information and regulations. Operate the appliance only when fully installed and with all safety
equipment fi tted.
2.1 Intended use
The appliance is intended for heating domestic hot water and can supply several draw-off points.
Any other use beyond that described shall be deemed inappro­priate.
Observation of these instructions is also part of the correct use of this appliance.
2.2 General Information
Read this entire manual. Failure to follow all the guides, instruc­tions and rules could cause personal injury or property damage. Improper installation, adjustment, alteration, service and use of this appliance can result in serious injury.
This appliance must be installed by a licensed electrician and plumber. The installation must comply with all national, state and local plumbing and electric codes. Proper installation is the re­sponsibility of the installer. Failure to comply with the installation and operating instructions or improper use voids the warranty.
Save these instructions for future reference. Installer should leave these instructions with the consumer.
If you have any questions regarding the installation, use or opera­tion of this water heater, or if you need any additional installation manuals, please call our technical service line, see last side.
2.3 Safety Precautions
!
DANGER: Injury Please read and follow these instructions. Failure to follow these instructions could result in seri­oius personal injury or death.
!
Damage to the appliance and the environment
The appliance must be installed by a licensed electrician and plumber. The installation must comply with all nati­onal, state and local plumbing and electric codes. Service of the appliance must be performed by qualifi ed service TECHNICIANS.
DANGER: Electrocution Before proceeding with any installation, adjustment. al­teration, or service of this appliance all circuit breakers and disconnect switches servicing the appliance must be turned off. Failure to do so could result in serious personal injury or death.
DANGER: Electrocution Never remove the appliance‘s cover unless the electricity servicing the appliance is turned off. Failure to do so could result in personal injury or death.
DANGER: Electrocution The appliance must be properly grounded. Failure to electrically ground the product could result in serious personal injury or death.
DANGER: Burns Water temperatures over 125°F (52 °C)can cause severe burns instantly or death from scalding. A hot water scal­ding potential exists if the thermostat on the appliance is set too high. Households with small children, disabled or elderly persons may require that the thermostat be set at 113°F (45 °C) or lower to prevent possible injury from hot water.
!
WARNING: Injury Where children or persons with limited physical, sensory or mental capabilities are to be allowed to control this appliance, ensure that this will only happen under su­pervision or after appropriate instructions by a person responsible for their safety. Children should be supervised to ensure that they never play with the appliance.
2.4 Test symbols
See type plate on the appliance.
OPERATION
REGISTER YOUR PRODUCT
4 | DHC-E WWW.STIEBEL-ELTRON-USA.COM
3. Register your product
YOU MUST REGISTER THIS PRODUCT WITHIN 90 DAYS OF PURCHASE ON OUR WEB SITE IN ORDER TO ACTIVATE THE STANDARD
WARRANTY OR TO BE ELIGIBLE FOR THE EXTENDED WARRANTY. GO TO OUR WEB SITE AT WWW.STIEBEL-ELTRON-USA.COM AND CLICK ON REGISTER YOUR PRODUCT.
Before beginning the registration process, we suggest that you gather the necessary information which will be as follows:
Type, Example: DHC-E
Number listed after “Nr.” Place of Purchase Purchase Date First & Last Name Email address Physical Address Phone Number Installation Date
IF YOU HAVE ANY QUESTIONS CONCERNING THE REGISTRA­TION PROCESS OR WARRANTY OPTIONS, PLEASE CONTACT STIEBEL ELTRON USA DIRECTLY AT (800)-582-8423.
4. General
The tankless water heater differs from conventional storage type water heaters in several ways. It does not store hot water. Instead, water is heated instantaneously as it fl ows through the appliance. Due to the absence of stand-by losses, the appliance offers greater energy effi ciency than storage type water heaters.
26_02_02 _1086
The input of heat into the water is electronically controlled. The appliance will deliver any water temperature between 86°F (30 °C) and 140 °F (60 °C). Please set the desired temperature using the knob on the front cover.
Note:
For reasons of appliance effi ciency and durability (sca­ling), the optimum temperature setting lies between 86°F (30°C) and 120°F (50°C).
In case the “Power” light is fl ashing while the appliance operates, the water fl ow rate exceeds the heating capacity of the appli­ance. Reduce the hot water fl ow rate in order to let the appliance achieve the set point temperature. The maximum temperature is electronically limited to 140 °F (60 °C). In case you have questions regarding the way you plan to use the appliance, please call our technical service line, see last side.
5. Troubleshooting
Symptom Possible Cause Solution
No hot water not enough flow rate to
activate appliance
clean faucet aerator or shower head
Water not hot enough water flow too high reduce water flow rate until
light on front cover stops blinking
If you cannot remedy the fault, notify the contractor who installed the appliance. To facilitate and speed up y our enquiry, please pro­vide the serial number from the type plate (000000-0000-000000).
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM DHC-E | 5
INSTALLATION
MOUNTING THE APPLIANCE
INSTALLATION
6. Mounting the appliance
6.1 Application
One appliance can be used for the following applications:
one or multiple hand washing sinks one kitchen sink cabins with fl ow restriction at shower head. A combination of two appliance can be used for whole apartment
and house applications. Please contact STIEBEL ELTRON for special installation instructions.
All areas with a ground water temperature likely to exceed 65°F (18°C) year round:
Whole apartment or house
CAUTION: Electrocution Unit must be installed in a vertical position with the water fi ttings pointing downward. In this position the unit is splashproof, so that no water can soak in.
12
3
4
5 6
7
26_02_02 _1082
1
2 3
4
5 6
7
26_02_02 _1081
1 Hot valve (left) 2 Cold valve (right) 3 Sink 4 1/2“ main pipe 5 Water supply line for faucet installation 6 Shut-off valve 7 Electrical junction box
6.2 Mounting
 Install appliance as close as possible to the main hot water
draw-off points.
 Install appliance in a frost free area. If frost may occur, re-
move appliance before freezing temperatures set in.
 Leave a minimum of 5“ of clearance on all sides for servicing.
26_02_02 _1083
 Remove plastic cover.
26_02_02_033126_02_02 _1090
 Screw the screws into the wall and hang the appliance.
Screws and plastic wall anchors for mounting on masonry or wood are provided.
 Secure the screws.
6 | DHC-E WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
WATER CONNECTIONS
7. Water connections
!
Damage to the appliance and the environment:
Excessive heat from soldering on copper pipes near the DHC may cause damage.
 All plumbing work must comply with national and applicable
state and local plumbing codes.
 Notice for Australia / New Zealand:
The installation shall comply with AS/NZS 3500.4.
 A pressure reducing valve must be installed if the cold water
supply pressure exceeds 150 PSI (10 bar).
 Make certain that the cold water supply line has been fl ushed
to remove any scale and dirt.
 Install isolating valve in cold water line as shown in illustra-
tion “Mounting the appliance”. This allows the appliance to be isolated for maintenance purposes.
 Cold water connection (inlet) is on the right side of the ap-
pliance, hot water connection (outlet) is on the left side of appliance.
 Tankless water heaters such as the DHC-E are not required to
be equipped with a Pressure and Temperature Relief Valve (P&T). If the local inspector will not pass the installation without a P&T, it should be installed on the hot water outlet side of appliance.
 The appliance is designed for connection to copper tubing,
PEX tubing or a braided stainless steel hose with a ½“ NPT female tapered thread. If soldering near the appliance is nec­essary, please direct the fl ame away from the plastic housing of the appliance in order to avoid damage.
 When all plumbing work is completed, check for leaks and
take corrective action before proceeding.
8. Electrical connection
DANGER: Electrocution Carry out all electrical connection and installation work in accordance with relevant regulations.
DANGER: Electrocution Only use a permanent connection to the power supply. The appliance must be able to be separated from the power supply by an isolator that disconnects all poles with at least 3mm contact separation.
!
Damage to the appliance and the environment:
Observe the type plate. The specifi ed voltage must match the mains voltage.
DANGER: Electrocution Before beginning any work on the electric installati­on, be sure that main breaker panel switch is „off“ to avoid any danger of electric shock. All mounting and plumbing must be completed before proceeding with electrical hook-up. Where required by local, state or national electrical codes the circuit should be equipped with a „ground fault interrupter“.
DANGER: Electrocution As with any electric appliance. failure to electrically ground appliance may result in serious injury or death.
 The appliance should be connected to a properly grounded
dedicated branch circuit of proper voltage rating. In installa­tions with several appliances, each appliance requires an independent circuit. Please refer to the technical data table for the correct wire and circuit breaker size.
4˝ (100 mm)
26_02_02 _1084
 The wire must be fed through the rubber seal located be-
tween the hot and cold water connections. Then feed wires through strain relief clamp and tighten clamp down on wire. The „live“ wires must be connected to the slots on the ter­minal block marked L and L (L and N). The ground wire must be connected to slot marked with the ground symbol. Strain relief clamp with screws and rubber seal are provided.
8.1 DHC-E 8/10 - Appliance with output power op­tions
For the DHC-E 8/10 instantaneous water heater, the output power is adjustable in 2 stages. In its delivered condition the appliance is set to 7.2 kW@240 V.
1
26_02_02 _1088
1 coding plug If the appliance should be installed with a different output power,
take the following steps:
 Insert the coding plug to the desired performance.
Stage 1 208 V 220 V 230 V 240 V
5,4 kW 6,0 kW 6,6 kW 7,2 kW
Stage 2 208 V 220 V 230 V 240 V
7,2 kW 8,1 kW 8,8 kW 9,6 kW
 Mark the selected output power and voltage on the type plate
with a permanent marker.
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM DHC-E | 7
INSTALLATION
COMMISSIONING
8.2 DHC-E 11 L
The DHC-E 11 L is only designed for a 208 V or 220 V connection. Do not connect to a 120 V or a 230-240 V electrical service.
8.3 Temperature setting/anti-scalding protection
26_02_02 _1089
 Connect the lead of the electronic temperature control to po-
sition „A1“ in order to get the maximum outlet temperature of 140°F (60°C).
The maximum temperature can be limited to 109°F (43°C):
 Connect the lead of the electronic temperature control to po-
sition „A2“.
 Reinstall the plastic cover.
8.4 Terminal block
We recommend using stranded wire to connect to the terminal block. Crimp a ferrule over stranded bare wire to ensure a good connection.
Consult the chart below for the recommended torque amounts on the terminal block screws.
Screw Diameter (mm) Torque (N•cm) Torque (lbf•in)
2.8 30-40 2.65-3.54
2.8-3 35-50 3.09-4.42 3-3.2 50-60 4.42-5.31
3.2-3.6 60-80 5.31-7.08
3.6-4.1 90-120 7.96-10. 62
4.1-4.7 120-180 10.62-15.93
4.7-5.3 150-200 13.27-17.7
Using the proper torque specifi cations to secure wire to the wiring block helps to avoid personal loss or property damage.
See 12.4, “Data table”, pg. 11 for information on the proper wire gauge size.
9. Commissioning
DANGER: Electrocution Commissioning must onl y be ca rried out by an aut horised contractor in accordance with safety regulations.
!
Damage to the appliance and the environment:
Open hot water faucet for a few minutes until water fl ow is continuous and all air is purged from water pipes. The appliance’s plastic cover must be installed before the cir­cuit breaker is turned on.
 Turn on circuit breaker to bring electrical power to the
appliance.
 Turn the temperature selector clockwise and anti-clockwise,
to calibrate the temperatur selector.
 Adjust the water temperature to the desired level using the
knob on the front cover of the appliance.
 Turn on hot water and wait twenty seconds until temperature
has stabilized.
 Check the water temperature with your hand and make sure
that it does not feel too hot. Reduce temperature if this is necessary. A setting of 108°F - 116°F (42 - 47°C) is recom­mended for most applications.
 Explain to the user how the appliance works and familiarise
him or her with its use.
 Advise the user about possible hazards (hot water tempera-
ture up to 140°F (60°C). Hand over these instructions, to be kept for future reference.
 A setting of 108°F - 116°F (42 - 47 °C) is recommended for
most applications.
9.1 Appliance handover
Explain the functions of the appliance to the user. Draw special attention to the safety information. Hand the operating and instal­lation instructions to the user.
8 | DHC-E WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
TROUBLESHOOTING
10. Troubleshooting
DANGER: Electrocution
To test the appliance, it must be supplied with power.
10.1 Display options LED diagnostic „traffi c lights“
Display options
red illuminates in case of faults
yellow illuminates when the appliance is heating water green flashing: The appliance is supplied with power
1
26_02_02 _1088
1 LED diagnostic „traffi c lights“
10.2 Fault table
Symptom Possible Cause Solution
No hot water
circuit breaker off safety thermal cut-out tripped
turn circuit breaker on reset thermal cut-out
not enough flow rate to activate appliance
clean filter screen at appli­ance
clean faucet aerator or
shower head
Not enough hot water filter screen clogged clean filter screen at appli-
ance
Water not hot enough water flow too high
reduce water flow rate until light on front cover stops blinking
supply correct voltage to
appliance
 If you are not able to resolve a problem please contact us,
see last side, before removing the appliance from the wall. STIEBEL ELTRON is happy to provide technical assistance. In most instances, we can resolve the problem over the phone.
11. Normal maintenance
STIEBEL ELTRON tankless water heaters are designed for a very long service life. Actual life expectancy will vary with water qual­ity and use. The appliance itself does not require any regular maintenance.
However, to ensure consistent water fl ow, it is recommended to periodically remove scale and dirt that may build up at the aera­tor of the faucet(s), the fi lter screen in the appliance, or in the shower head.
12. Technical Data
12.1 Dimensioned drawing
b01
c06 c01
c01
c06
4˝(10 cm)
4¼˝(11 cm)
1½˝(3.8 cm)
7¾˝(20 cm)
¼˝(.8 cm)
14¼˝(36 cm)
3˝(7.5 cm)
10¾˝(27.3 cm)
D0000017762
b01 Electrical cable entry c01 cold water inlet ½˝ NPT c06 hot water outlet ½˝ NPT
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM DHC-E | 9
INSTALLATION
TECHNICAL DATA
12.2 Wiring diagram
DHC-E 8/10
2/GRD ~ 208 / 240 V
1/N/PE ~ 220 / 230 / 240 V
85_02_03_0001
DHC-E 11 L
2/GRD ~ 208 V
1/N/PE ~ 220 V
85_02_03_0001
DHC-E 12
2/GRD ~ 208 / 240 V
1/N/PE ~ 220 / 230 / 240 V
85_02_03_0002
10 | DHC-E WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
TECHNICAL DATA
12.3 Maximum temperature increase above ambient water temperature
Hot water fl ow rate [ GPM ]
Hot water outlet temperature 104 °F
Cold water inlet temperature °F 39 50 59 68 77 86 95 104 113 122 131 DHC-E 8/10
5.4 kW @ 208 V 0.57 0.68 0.82 1.02 1.36 2.04 4.09 - - - -
7.2 kW @ 240 V 0.76 0.91 1.09 1.36 1.82 2.72 5.45 - - - -
7.2 kW @ 208 V 0.76 0.91 1.09 1.36 1.82 2.72 5.45 - - - -
9.6 kW @ 240 V 1.01 1.21 1.45 1.82 2.42 3.63 6.61 - - - ­DHC-E 11 L
10.4 kW @ 208 V 1.09 1.31 1.57 1.97 2.62 3.74 6.61 - - - -
11.6 kW @220 V 1.22 1.47 1.76 2.2 2.93 4.18 6.61 - - - ­DHC-E 12
9 kW @ 208 V 0.95 1.14 1.36 1.70 2.27 3.23 6.47 - - - -
12 kW @ 240 V 1.26 1.51 1.82 2.27 3.03 4.31 6.61 - - - -
Hot water outlet temperature 113 °F
Cold water inlet temperature °F 39 50 59 68 77 86 95 104 113 122 131 DHC-E 8/10
5.4 kW @ 208 V 0.50 0.58 0.68 0.82 1.02 1.36 2.04 4.09 - - -
7.2 kW @ 240 V 0.66 0.78 0.91 1.09 1.36 1.82 2.72 5.45 - - -
7.2 kW @ 208 V 0.66 0.78 0.91 1.09 1.36 1.82 2.72 5.45 - - -
9.6 kW @ 240 V 0.89 1.04 1.21 1.45 1.82 2.42 3.63 6.61 - - ­DHC-E 11 L
10.4 kW @ 208 V 0.96 1.12 1.31 1.57 1.97 2.49 3.74 6.61 - - -
11.6 kW @220 V 1.07 1.26 1.47 1.76 2.2 2.79 4.18 6.61 - - ­DHC-E 12
9 kW @ 208 V 0.83 0.97 1.14 1.36 1.70 2.16 3.23 6.47 - - -
12 kW @ 240 V 1.11 1.30 1.51 1.82 2.27 2.88 4.31 6.61 - - -
Hot water outlet temperature 140 °F
Cold water inlet temperature °F 39 50 59 68 77 86 95 104 113 122 131 DHC-E 8/10
5.4 kW @ 208 V 0.36 0.41 0.45 0.51 0.58 0.68 0.82 1.02 1.36 2.04 4.09
7.2 kW @ 240 V 0.49 0.54 0.61 0.68 0.78 0.91 1.09 1.36 1.82 2.72 5.45
7.2 kW @ 208 V 0.49 0.54 0.61 0.68 0.78 0.91 1.09 1.36 1.82 2.72 5.45
9.6 kW @ 240 V 0.65 0.73 0.81 0.91 1.04 1.21 1.45 1.82 2.42 3.63 6.61 DHC-E 11 L
10.4 kW @ 208 V 0.70 0.79 0.87 0.98 1.12 1.25 1.50 1.87 2.49 3.74 6.61
11.6 kW @220 V 0.78 0.88 0.98 1.1 1.26 1.39 1.67 2.09 2.79 4.18 6.61 DHC-E 12
9 kW @ 208 V 0.61 0.68 0.76 0.85 0.97 1.08 1.29 1.62 2.16 3.23 6.47
12 kW @ 240 V 0.81 0.91 1.01 1.14 1.30 1.44 1.73 2.16 2.88 4.31 6.61
Hot water fl ow rate [ l/min ]
Hot water outlet temperature 40 °C
Cold water inlet temperature °C 4 10 15 20 25 30 35 40 45 50 55 DHC-E 8/10
5.4 kW @ 208 V 2.15 2.58 3.09 3.87 5.16 7.7 3 15.47 - - - -
7.2 kW @ 240 V 2.86 3.44 4.12 5.16 6.87 10.31 20.62 - - - -
7.2 kW @ 208 V 2.86 3.44 4.12 5.16 6.87 10.31 20.62 - - - -
9.6 kW @ 240 V 3.82 4.58 5.50 6.87 9.16 13.75 25.00 - - - ­DHC-E 11 L
10.4 kW @ 208 V 4.13 4.96 5.96 7. 45 9.93 14.15 25.02 - - - -
11.6 kW @220 V 4.62 5.55 6.66 8.33 11.11 15.83 25.02 - - - ­DHC-E 12
9 kW @ 208 V 3.58 4.30 5.16 6.44 8.59 12.24 24.49 - - - -
12 kW @ 240 V 4.77 5.73 6.87 8.59 11.46 16.32 25.00 - - - -
Hot water outlet temperature 45 °C
Cold water inlet temperature °C 4 10 15 20 25 30 35 40 45 50 55 DHC-E 8/10
5.4 kW @ 208 V 1.89 2.21 2.58 3.09 3.87 5.16 7.73 15.47 - - -
7.2 kW @ 240 V 2.51 2.95 3.44 4.12 5.16 6.87 10.31 20.62 - - -
7.2 kW @ 208 V 2.51 2.95 3.44 4.12 5.16 6.87 10.31 20.62 - - -
9.6 kW @ 240 V 3.35 3.93 4.58 5.50 6.87 9.16 13.75 25.00 - - ­DHC-E 11 L
10.4 kW @ 208 V 3.62 4.26 4.96 5.96 7.4 5 9.43 14.15 25.02 - - -
11.6 kW @220 V 4.05 4.76 5.55 6.66 8.33 10.55 15.83 25.02 DHC-E 12
9 kW @ 208 V 3.14 3.68 4.30 5.16 6.44 8.16 12.24 24.49 - - -
12 kW @ 240 V 4.19 4.91 5.73 6.87 8.59 10.88 16.32 25.00 - - -
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM DHC-E | 11
INSTALLATION
TECHNICAL DATA
Hot water outlet temperature 60 °C
Cold water inlet temperature °C 4 10 15 20 25 30 35 40 45 50 55 DHC-E 8/10
5.4 kW @ 208 V 1.38 1.55 1.72 1.93 2.21 2.58 3.09 3.87 5.16 7.73 15.47
7.2 kW @ 240 V 1.84 2.06 2.29 2.58 2.95 3.44 4.12 5.16 6.87 10.31 20.62
7.2 kW @ 208 V 1.84 2.06 2.29 2.58 2.95 3.44 4.12 5.16 6.87 10.31 20.62
9.6 kW @ 240 V 2.45 2.75 3.05 3.44 3.93 4.58 5.50 6.87 9.16 13.75 25.00 DHC-E 11 L
10.4 kW @ 208 V 2.65 2.98 3.31 3.72 4.26 4.72 5.66 7.07 9.43 14.15 25.02
11.6 kW @220 V 2.97 3.33 3.7 4.17 4.76 5.28 6.33 7.91 10.55 15.83 25.02 DHC-E 12
9 kW @ 208 V 2.30 2.58 2.86 3.22 3.68 4.08 4.90 6.12 8.16 12.24 24.49
12 kW @ 240 V 3.07 3.44 3.82 4.30 4.91 5.44 6.53 8.16 10.88 16.32 25.00
12.4 Data table
DHC-E 8/10
*
Part number 224201 (U.S. & Canada) / 234450 (Export) Phase 1 1 1 1 1 1 1 1 Coding plug Position 1 1 1 1 2 2 2 2 Voltage V 208 220 230 240 208 220 230 240 Frequency Hz 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 Output power kW 5.4 6.0 6.6 7.2 7.2 8.1 8.8 9.6 Amperage A 28 30 31 32 35 37 39 40 Min. recommended circuit breaker1 (DP) A 30 40 40 40 35 40 40 40 Min. recommended wire size2 (copper) AWG 8 8 8 8 8 8 8 8 Min. water flow to activate appliance GPM / l/min 0.26 / 1 Protection level according to IP 24 Max. inlet water temperature °F / °C 131 / 55 Nominal water volume GAL / l 0.13 / 0.5 Working pressure max. PSI / bar / MPa 150 / 10 / 1 Tested to pressure PSI / bar / MPa 300 / 20 / 2 Weight lbs. / kg 5.9 / 2.7 Water connections 1/2“ NPT
DHC-E 11 L DHC-E 12
Part number
235235 230628 (U.S. & Canada) /
234451 (Export) Phase 1 1 1 1 1 1 Voltage V 208 220 208 220 230 240 Frequency Hz 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 Output power kW 10.4 11.6 9 10 11 12 Amperage A 50 52.8 44 46 48 50 Min. recommended circuit breaker1 (DP) A 50 60 50 50 50 50 Min. recommended wire size2 (copper) AWG COPPER 6 6 6 6 6 6 Protection level according to IP 24 Min. water flow to activate appliance GPM / l/min 0.26 / 1 Max. inlet water temperature °F / °C 131 / 55 Nominal water volume GAL / l 0.13 / 0.5 Working pressure max. PSI / bar / MPa 150 / 10 / 1 Tested to pressure PSI / bar / MPa 300 / 20 / 2 Weight lbs. / kg 5.9 / 2.7 Water connections 1/2“ NPT
*
DHC-E 8/10 is a single unit that is switchable at installation via jumper for out put at 7.2 kW (Stage 1) or 9.6 kW (Stage 2).
1
This is our recommendation for overcurrent protection sized at 100% of load. Check local codes for compliance if necessary.
Tankless water heaters are considered a non-continuous load.
2
Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
12 | DHC-E WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
SPARE PARTS
13. Spare parts
2
1
13
6
35
10
11
15
14
987
12
26_02_02 _1091
4
No. No. Spare par t DHC-E 8/10 DHC-E 11 L DHC-E 12
1 Heating system 292575 320979 292576 2 Safety thermal cut out 286369 286369 286369 3 Electronic control appliance 291851 291852 291852 4 Coding plug 283455 - ­5 Back panel 292578 292578 292578 6 Flow sensor DFE 286461 286461 286461 7 Cold water connection 291699 291699 291699 8 Filter screen 252430 252430 252430 9 Hot water connection 278634 278634 278634 10 Plastic cover 292577 292577 292577 11 Wiring block 279998 279998 279998 12 Axis connection plug 254312 254312 254312 13 Electronic temperature control 286359 286359 286359 14 Temperature adjustment knob 254307 254307 254307 15 Outlet temperature sensor 280677 280677 280677
WWW.STIEBEL-ELTRON-USA.COM DHC-E | 13
ENGLISH
WARRANTY | ENVIRONMENT AND RECYCLING
Environment and recycling
Please help us protect the environment. Dispose of the appliance and its packaging in accordance with national regulations.
17 West Street West Hat eld, MA 01088
TOLL FREE 800.582.8423 PHONE 413.247.3380 FAX 413.247.3369
info
@
stiebel-eltron-usa.com
www.stiebel-eltron-usa.com
LIMITED WARRANTY
This Warranty is valid for U.S.A. & Canada only. Warranties may vary by country. Please consult your local Stiebel Eltron Representative for the Warranty for your country.
Subject to the terms and conditions set forth in this limited warranty, Stiebel Eltron, Inc. (the “Manufacturer”) hereby warrants to the original purchaser (the “Owner”) that each Tankless Electric Domestic Hot Water Heater (the “Heater”) shall not (i) leak due to defects in the Manufacturer’s materials or workmanship for a period of seven (7) years from the date of purchase or (ii) fail due to defects in the Manufacturer’s materials or workmanship for a period of three (3) years from the date of purchase. As Owner’s sole and exclusive remedy for breach of the above warranty, Manufacturer shall, at the Manufacturer’s discretion, send replacement parts for local repair; retrieve the unit for factory repair, or replace the defective Heater with a replacement unit with comparable operating features. Manufacturer’s maximum liability under all circumstances shall be limited to the Owner’s purchase price for the Heater.
This limited warranty shall be the exclusive warranty made by the Manufacturer and is made in lieu of all other warranties, express or implied, whether written or oral, including, but not limited to warranties of merchantability and fi tness for a particular purpose. Manufacturer shall not be liable for incidental, consequential or contingent damages or expenses arising directly or indirectly from any defect in the Heater or the use of the Heater. Manufacturer shall not be liable for any water damage or other damage to property of Owner arising, directly or indirectly, from any defect in the Heater or the use of the Heater. Manufacturer alone is authorized to make all warranties on Manufacturer’s behalf and no statement, warranty or guarantee made by any other party shall be binding on Manufacturer.
Manufacturer shall not be liable for any damage whatsoever relating to or caused by:
1. any misuse or neglect of the Heater, any accident to the Heater, any alteration of the Heater, or any other unintended use;
2. acts of God and circumstances over which Manufacturer has no control;
3. installation of the Heater other than as directed by Manufacturer and other than in accordance with applicable building codes;
4. failure to maintain the Heater or to operate the Heater in accordance with the Manufacturer’s specifi cations;
5. operation of the Heater under fl uctuating water pressure or in the event the Heater is supplied with non-potable water, for any duration;
6. improper installation and/or improper materials used by any installer and not relating to defects in parts or workmanship of Manufacturer;
7. moving the Heater from its original place of installation;
8. exposure to freezing conditions;
9. water quality issues such as corrosive water, hard water, and water contaminated with pollutants or additives;
Should owner wish to return the Heater to manufacturer for repair or replacement under this warranty, Owner must fi rst secure written authorization from Manufacturer. Owner shall demonstrate proof of purchase, including a purchase date, and shall be responsible for all removal and transportation costs. If Owner cannot demonstrate a purchase date this warranty shall be limited to the period beginning from the date of manufacture stamped on the Heater. Manufacturer reserves the right to deny warranty coverage upon Manufacturer’s examination of Heater. This warranty is restricted to the Owner and cannot be assigned.
Some States and Provinces do not allow the exclusion or limitation of certain warranties. In such cases, the limitations set forth herein may not apply to the Owner. In such cases this warranty shall be limited to the shortest period and lowest damage amounts allowed by law. This warranty gives you specifi c legal rights and you may also have other rights which vary from State to State or Province to Province.
Owner shall be responsible for all labor and other charges incurred in the removal or repair of the Heater in the fi eld. Please also note that the Heater must be installed in such a manner that if any leak does occur, the fl ow of water from any leak will not damage the area in which it is installed.
14. Warranty
14 | DHC-E WWW.STIEBEL-ELTRON.COM
ÍNDICE|OPERACIÓN
INDICACIONES GENERALES
OPERACIÓN
1. Indicaciones generales ____________________________________ 14
1.1 Indicaciones para el cableado: _______________________________ 14
1.2 Otras marcas presentes en este documento ______________ 15
2. Seguridad ___________________________________________________ 15
2.1 Uso previsto ______________________________________________________ 15
2.2 Información general ___________________________________________15
2.3 Medidas de seguridad _________________________________________ 15
2.4 Sello de certifi cación ___________________________________________ 15
3. Registre su producto ______________________________________ 16
4. Descripción del equipo ___________________________________ 16
5. Solución de problemas ____________________________________ 16
INSTALACIÓN
6. Descripción del equipo ____________________________________ 17
7. Montaje _____________________________________________________ 17
8. Conexión de agua __________________________________________ 18
9. Conexión eléctrica _________________________________________ 18
9.1 DHC-E 8/10 – Selección de potencia _________________________18
9.2 DHC-E 11 L ________________________________________________________ 19
9.3 Ajuste de temperatura/protección antiescaldamiento _ 19
9.4 Bloque de terminales __________________________________________ 19
10. Puesta en marcha __________________________________________ 19
11. Localización y reparación de fallos_______________________ 19
11.1 Posibilidades de indicación de los LED de diagnóstico __ 19
11.2 Tabla de averías _________________________________________________ 20
12. Mantenimiento _____________________________________________ 20
13. Especifi caciones técnicas __________________________________ 20
13.1 Plano dimensional ______________________________________________ 20
13.2 Diagrama eléctrico _____________________________________________ 21
13.3 Posibles caudales para distintas temperaturas de entra­da y de salida ____________________________________________________ 22
13.4 Tabla de especifi caciones _____________________________________23
14. Piezas de recambio ________________________________________ 24
15. Garantía _____________________________________________________ 25
OPERACIÓN
1. Indicaciones generales
Indicación:
Lea atentamente estas instrucciones antes de utilizar el aparato y familiarícese con sus funciones. Conserve este manual en un lugar seguro. Si entregara este aparato a otros usuarios no olvide incluir el manual.
1.1 Indicaciones para el cableado:
1.1.1 Estructura de las indicaciones de seguridad
ADVERTENCIA de tipo de peligro Aquí aparecen las posibles consecuencias del des­obedecimiento de las indicaciones de seguridad.
 Se indican las medidas necesarias para evitar
estos peligros.
1.1.2 Símbolos, tipo de peligro
Símbolo Tipo de peligro
!
Lesión
Electrocución
Quemadura o escaldamiento
1.1.3 Palabras clave
PALABRA CLAVE Descripc ión
PELIGRO El desobedecimiento de esta información conlleva
graves lesiones o la muerte
ADVERTENCIA El desobedecimiento de esta información puede con-
llevar graves lesiones o la muerte
ATENCIÓN El desobedecimiento de esta información puede con-
llevar lesiones de mediana gravedad o lesiones leves
OPERACIÓN
SEGURIDAD
WWW.STIEBEL-ELTRON.COM DHC-E | 15
ESPAÑOL
1.2 Otras marcas presentes en este documento
Indicación:
La indicación está limitada por líneas horizontales sobre y bajo el texto. La información general se señaliza me­diante el símbolo que se muestra a la izquierda.
 Lea atentamente las indicaciones.
Símbolo
!
Daños en el aparato y al medio ambiente
Eliminación del aparato
 Este símbolo indica que debe usted hacer algo. Lo que debe
hacer se describe en pasos individuales.
2. Seguridad
Observe las siguientes indicaciones y normas de seguridad. El equipo sólo debe utilizarse después de haber sido instalado
completamente y con todos los dispositivos de seguridad.
2.1 Uso previsto
El aparato está previsto para el calentamiento del agua potable y puede abastecer varios puntos de extracción.
El uso fuera de las especifi caciones descritas se considera inde­bido.
Además, el obedecimiento de las presentes instrucciones forma parte del uso previsto de este aparato.
2.2 Información general
Lea el manual íntegramente. El desobedecimiento de las normas, instrucciones y reglamentos puede causar lesiones físicas a per­sonas y/o daños materiales. La instalación, ajuste, modifi cación y mantenimiento incorrectos del presente aparato puede conducir a lesiones físicas considerables.
Este aparato debe ser instalado por un técnico autorizado. La ins­talación debe cumplir toda la normativa nacional, regional y local. El técnico especializado es responsable de la correcta instalación. El desobedecimiento de las instrucciones de instalación y opera­ción o el uso indebido conducen a la anulación de la garantía.
Guarde el presente manual para futuras consultas. El técnico es­pecializado debe entregar este manual al usuario.
En caso de cualquier consulta relativa a la instalación, uso u ope­ración del presente calentador o, si fuera preciso en relación a cualquier otro manual de instalación, diríjase al teléfono de ser­vicio técnico (véase última página).
2.3 Medidas de seguridad
!
PELIGRO: Lesiones Lea y obedezca las siguientes instrucciones. El desobedecimiento de esta información puede conlle­var graves lesiones o la muerte.
!
Daños en el aparato y al medio ambiente:
Este aparato debe ser instalado por un técnico autoriza­do. La instalación debe cumplir toda la normativa nacio­nal, regional y local. El mantenimiento del aparato debe ser realizado por téc­nicos autorizados.
PELIGRO: Electrocución Antes de llevar a cabo cualquier tarea de instalación, ajuste, modifi cación o mantenimiento de este aparato deben desconectarse todos los interruptores de potencia y seccionadores de alimentación eléctrica del aparato. El desobedecimiento de estas indicaciones puede conllevar graves lesiones o la muerte.
PELIGRO: Electrocución Sólo podrá retirar la cubierta del aparato si se ha inte­rrumpido la alimentación eléctrica del aparato. El des­obedecimiento de estas indicaciones puede conllevar lesiones físicas o la muerte.
PELIGRO: Electrocución El aparato debe conectarse a tierra adecuadamente. Si no se conecta a tierra el producto pueden producirse graves lesiones físicas o incluso la muerte.
PELIGRO: Quemaduras Las temperaturas del agua que superen los 125 °F (52 °C) pueden causar quemaduras graves repentinas o incluso la muerte por escaldamiento. El peligro de escaldamien­to con agua caliente existe si el termostato del aparato presenta un ajuste demasiado alto. En hogares con niños pequeños, personas discapacitadas o personas mayores puede ser necesario ajustar el termostato a 113 °F (45 °C) o menos para evitar lesiones físicas por agua caliente.
!
ADVERTENCIA: Peligro de lesiones Si niños o personas con discapacitación f ísica, sensorial o mentalmente, operan el aparato debe asegurarse de que dicha operación se realice después de haber recibido la instrucción adecuada por una persona a su cargo. En el caso de los niños debe procurar que no jueguen con el aparato.
2.4 Sello de certifi cación
Consulte la placa de especifi caciones del aparato.
OPERACIÓN
REGISTRE SU PRODUCTO
16 | DHC-E WWW.STIEBEL-ELTRON.COM
3. Registre su producto
Nota:
Debe registrar este producto en un plazo de 90 días desde la compra a través de nuestra página web para activar cualquier garantía estándar o para optar a la ampliación de la garantía. Visite nuestra página web www.stiebel-eltron-usa.com y haga clic en “Registre su producto”.
Antes de comenzar el proceso de registro, le sugerimos que recopile la siguiente información que necesitará:
Modelo, ejemplo: DHC-E
Número que se indica después de “Nr.” Lugar de compra Fecha de compra Nombre y apellido Dirección de email Dirección postal Número de teléfono Fecha de instalación
Si tiene alguna pregunta en relación con el proceso de re­gistro o con las opciones de garantía, por favor, póngase en contacto directamente con Stiebel Eltron USA en el número de teléfono (800)-582-8423.
4. Descripción del equipo
El calentador instantáneo DHC-E se distingue de los acumuladores de agua convencionales en varios aspectos. No acumula agua ca­liente. En lugar de ello, el agua se calienta de inmediato mientras fl uye a través del aparato. Debido a la ausencia de pérdidas de calor en modo standby, el DHC-E ofrece un rendimiento energético superior a un acumulador de agua caliente.
26_02_02 _1086
El calentamiento del agua se controla electrónicamente. El DHC-E puede suministrar agua a una temperatura de 86 °F (30 °C) a 140 °F (60 °C). La temperatura deseada puede ajustarse mediante el re­gulador de temperatura.
Indicación
Por razones de efi ciencia y vida útil (calcifi cación) del aparato, el rango de ajuste óptimo de la temperatura está entre 30°C (86°F) y 50°C (120°F).
Si durante el funcionamiento del aparato parpadea la luz “power” (alimentación), el caudal del agua es superior a lo que puede calentar la potencia calefactora del aparato. En ese caso, reduzca el caudal para que el aparato pueda proporcionar la temperatura ajustada. La temperatura máxima está limitada electrónicamen­te a 140 °F. Si tuviera cualquier pregunta adicional sobre el uso previsto del DHC-E, diríjase al teléfono de nuestro servicio técnico (véase última página).
5. Solución de problemas
Problema Causa Solución
No hay agua caliente El caudal de agua no es
suficiente para la acti­vación del aparato
Limpiar el regulador de chorro o el cabezal de la ducha
El agua no está sufi­cientemente caliente
El caudal de agua es demasiado alto
Reducir el caudal hasta que la luz de la cubierta frontal deje de parpadear
Si no puede solucionar la causa llame al instalador. Para poder ayudarle mejor y con mayor agilidad, indique el número de la placa de especifi caciones (000000-0000-000000).
Loading...