Sterling RTAA-70, RTAA-90, RTAA-80, RTAA-IOM-4A, RTAA-IOM-4 User Manual

...

Specifications and Main Features

  • Rotary Liquid Chillers of the Model RTAA Series R®
  • The unit is available in a capacity range of 70 to 125 tons.
  • The unit employs Dual helically rotary compressor types with two independent refrigerant circuits.
  • Refrigerant used is HCFC-22.
  • Standard unit uses ambient air in a temp range of 15°F to 125°F, whereas low ambient models can use temp of up to -10°F.
  • Water Tank Capacity (in gallons):
  • RTAA-70: 39.8 gallons (150.6 liters)
  • RTAA-80: 37.8 gallons (143.1 liters)
  • RTAA-90: 34.4 gallons (130.2 liters)
  • RTAA-100: 32.1 gallons (121.5 liters)
  • RTAA-110: 53.4 gallons (202.1 liters)
  • RTAA-125: 45.8 gallons (173.4 liters)
  • Min. Chilled Water Flow (GPM):
  • RTAA-70: 84 GPM
  • RTAA-80: 96 GPM
  • RTAA-90: 198 GPM
  • RTAA-100: 123 GPM
  • RTAA-110: 132 GPM
  • RTAA-125: 140 GPM
  • Max. Chilled Water Flow (GPM):
  • RTAA-70: 252 GPM
  • RTAA-80: 288 GPM
  • RTAA-90: 324 GPM
  • RTAA-100: 360 GPM
  • RTAA-110: 396 GPM
  • RTAA-125: 450 GPM
  • Number of Coils: 4
  • Height of the Coil: 42 inches
  • The length of the coil is as follows:
  • RTAA-70: 13 feet
  • RTAA-80: 13 feet
  • RTAA-90: 14 feet
  • RTAA-100: 14 feet
  • RTAA-110: 17 feet
  • RTAA-125: 17 feet
  • Depending on the model, it has 4 to 5 Fans which are 30 inches in diameter
  • Electrical Data:
  • The unit operates on 200/230/460/575 volts
  • Most Applicable Full Load Amp: each models respective data table.
  • Logic Control: Employs Adaptive Control™ featuring a Clear Language Display Engine.
  • There are model basis settings for compressor overload dip switches.
  • There is an option to use a remote display unit that can be connected to the unit to display its operations from a distance.
  • Type of Package Unit: Oil and Refrigerant Charged, wired in the factory, leak tested and dehydrated.

Frequently Asked Questions

Q1: Nominal capacity limits for RTAA series can be in what metric ton range?

A1: Between 70-125 tons.

Q2: Which refrigerant does the RTAA series cold water product use?

A2: It incorporates HCFC-22 as a refrigerant.

Q3: What is the normal ambient temperature range for standard units in operation?

A3: For standard units post 15F ambient temperature it becomes feasible to operate them.

Q4: Is there a configuration available to supervise RTAA unit from a different location?

A4: Yes, a remote display can be operated to monitor unit's operation from a different location.

Q5: What is the procedure for charging the equipment to ensure there's no leakage?

A5: Equipment is charged with refrigerant and oil in factory before sending for shipment.

Q6: RTAA Units nMaintainance kya door hoing protectors

A6: Kool cleaning, oil checking and refrigerant charge monitoring is little bit regular maintenance.

Q7: What Power Supply is required to the RTAA series.

A7: RTAA series Power supply is needed for 3-phase supply with 200 VBox, 230, 460 and 575 volts.

User Manual

Page 1
Sterling RTAA-70, RTAA-90, RTAA-80, RTAA-IOM-4A, RTAA-IOM-4 User Manual
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Page 27
Page 28
Page 29
Page 30
Page 31
Page 32
Page 33
Page 34
Page 35
Page 36
Page 37
Page 38
Page 39
Page 40
Page 41
Page 42
Page 43
Page 44
Page 45
Page 46
Page 47
Page 48
Page 49
Page 50
Page 51
Page 52
Page 53
Page 54
Page 55
Page 56
Page 57
Page 58
Page 59
Page 60
Page 61
Page 62
Page 63
Page 64
Page 65
Page 66
Page 67
Page 68
Page 69
Page 70
Page 71
Page 72
Page 73
Page 74
Page 75
Page 76
Page 77
Page 78
Page 79
Page 80
Page 81
Page 82
Page 83
Page 84
Page 85
Page 86
Page 87
Page 88
Page 89
Page 90
Page 91
Page 92
Page 93
Page 94
Page 95
Page 96
Page 97
Page 98
Page 99
Page 100
Loading...