Stearns 1-087-7XX Catalog Page

Series 87,700 (1-087-7XX)
Mounting Face: NEMA 182TC 184TC, 213TC, 215TC, 254TC, 254UC, 256TC and 256UC Double C-Face Coupler
8.5” AK, 7.25” AJ
Static Torque: 6 through 105 lb-ft Enclosure Material:
automatic reset Enclosure Protection: IP 23, 54 & 55 (formerly
referred to by Stearns as NEMA 2, 4 & 4X BISSC Certified, respectively).
Installation and Service Instructions: P/N 8-078-927-27 Rev. B & C
Parts List: P/N 8-078-917-57 Rev. B P/N 8-078-917-67 Rev. C
Modifications: Pages 54-63
BACK TO T ABLE OF CONTENTS
Note: 87,700 Series mounts between C-Face motor and reducer. Do not apply overhung load to brake output shaft.
Modification required for vertical above mounting. For vertical below, modification required on 50-105 lb-ft..
• ABS Type Approval Certified
• Spring-Set Electrically Released
• Self-Adjusting Design
• Maximum Speed: Horizontal 4000 rpm Vertical 3600 rpm
• Certified: CSA File LR-6254
46
*
For X and U dimensions, see Ordering Information and Identification Information.
Dimensions for estimating only. For installation purposes request certified prints.
Dimensional Data
Nominal
Static
Torque lb-ft
(Nm)
(102)
(142)
*
X in 9th digit designates hub bore and shaft size.
10
(14)
15
(20)
25
(34)
35
(47)
50
(68)
75
105
Enclosure
IP 23 1-087-711-0X 1-087-715-0X IP 54 1-087-712-0X 1-087-716-0X IP 55 1-087-712-BX 1-087-716-BX IP 23 1-087-721-0X 1-087-725-0X
IP 55 1-087-722-BX 1-087-726-BX IP 23 1-087-731-0X 1-087-735-0X
IP 55 1-087-732-BX 1-087-736-BX IP 23 1-087-741-0X 1-087-745-0X
IP 55 1-087-742-BX 1-087-746-BX IP 23 1-087-751-0X 1-087-755-0X
IP 55 1-087-752-BX 1-087-756-BX IP 23 1-087-761-0X 1-087-765-0X
IP 55 1-087-762-BX 1-087-766-BX IP 23 1-087-781-0X 1-087-785-0X IP 54 IP 55 1-087-782-BX 1-087-786-BX
Basic Model Number
AC DC
1-087-782-0X 1-087-786-0X
** Hub location.
Dimensions in Inches
(Dimensions in Millimeters)
AAEAGC
8.38
(212.72)
8.38
(212.72)
8.38
(212.72)
8.38
(212.72)
8.88
(225.42)
8.88
(225.42)
9.38
(238.12)
2.12
(53.93)
2.12
(53.93)
2.12
(53.93)
2.12
(53.93)
2.62
(66.68)
2.62
(66.68)
3.12
(79.38)
.19
(4.83)
.19
(4.83)
.19
(4.83)
.19
(4.83)
.44
(11.18)
.44
(11.18)
1.00
(25.40)
2.81
(71.44)
2.81
(71.44)
2.81
(71.44)
2.81
(71.44)
3.31
(84.14)
3.31
(84.14)
3.81
(96.84)
(4) mounting holes equally spaced on a 7.25” (184.15) B.C. Use 1/2-13 x 1.25” mounting bolts.
Wt. lbs
(kg)**
66 (30.0)
66 (30.0)IP 54 1-087-722-0X 1-087-726-0X
66 (30.0)IP 54 1-087-732-0X 1-087-736-0X
66 (30.0)IP 54 1-087-742-0X 1-087-746-0X
73 (33.0)IP 54 1-087-752-0X 1-087-756-0X
73 (33.0)IP 54 1-087-762-0X 1-087-766-0X
80 (36.0)
Series 87,700 Specifications continued
BACK TO T ABLE OF CONTENTS
Specifications
Nominal
Static
Torque
lb-ft
(Nm)
10
(14)
15
(20)
25
(34)
35
(47)
50
(68)
75
(102)
105
(142)
1
Maximum solenoid cycle rate is based on ambient temperature of 72°F (22°C) with
50% duty cycle. Does not relate to brake cycle rate (see Thermal Capacity).
2
Thermal capacity rating is based on ambient temperature of 72°F (22°C), stop time
of one second or less, with no heat absorbed from motor. Derate thermal capacity by 25% for vertical mounting. Refer to Selection Procedure Section.
No. of
Friction
Solenoid
Discs
Size
1 5 30 1 6 25 1 6 25 1 8 20 2 6 25 2 8 20 3 8 20
Maximum
solenoid
Cycle Rate
cycles/
min
Thermal
Capacity
1
hp-sec/min
(watts)
17.5
(249)
17.5
(249)
17.5
(249)
17.5
(249)
17.5
(249)
17.5
(249)
17.5
(249)
Inertia (Wk2)
2
(kgm2 x 10-4)
lb-ft
.078
(32.76)
.078
(32.76)
.078
(32.76)
.078
(32.76)
.108
(45.36)
.108
(45.36)
.145
(60.90)
Current Ratings (amperes)
Coil Size
5
6
8
AC
Current
Inrush
Holding
Inrush
Holding
Inrush
Holding
Voltage: 60 Hz
115 200 230 400 460 575 110 220 380
7.5
4.3
3.7
2.2
1.9
.5
13.0 .6
17.6
1.2
.3
7.5 .4
10.3 .7
.2
6.5 .3
8.8 .6
.1
3.7 .2
5.0 .3
.1
3.2 .2
4.2 .3
1.5 .09
2.6 .1
3.5 .24
Voltage: 50 Hz
5.4
4.0
.3
.25
9.4
5.6
.5
.28
15.4
7.7
.1
.5
2
1.9 .1
3.2 .2
4.2 .3
Brake set and release times in milliseconds, when brake and motor are switched separately (for T1/T2 definitions, see page 101):
Static Torque Coil Size T1 T2
10, 15, 25, 50 5 & 6 42 20
35, 75, 105 8 48 20
Voltage: DC
24 95
38.0 .5
42.8 .6
43.1 .8
8.4 .1
11.7 .2
11.4 .2
115 230
5.6 .08
8.5 .1
9.3 .2
3.2 .04
3.7 .06
4.6 .09
Ordering and Identification Information
The following example and tables provide information for selecting the appropriate three-letter suffix when ordering a Stearns Brake. Example of a complete part number:
1-087-732-01-–FG Lead wire position (external, left and right) 230 Vac Does not apply Hub bore and output shaft size 1.125
Standard AC Voltage
Hub Bore, Shaft and Keyway Sizes
9th Digit of Model
Number
For sizes other than those shown, contact factory. No motor frame adapters or foot mounting kit available.
Keyseats made to ANSI B17.1 standard.
*
Bore Dia.
(X)
1.125
1
3
5
1.126
28.575
28.600
(
1.375
1.376
34.925
34.950
(
1.625
1.626
41.275
41.300
(
)
)
)
Dimensions in Inches
(Dimensions in Millimeters)
Keyway*
.25 x .12
(6.35 x 3.18)
.31 x .16
(7.94 x 3.97)
.38 x .19
(9.52 x 4.76)
Shaft Dia.
(U)
1.125
1.124
28.575
28.550
(
1.375
1.374
34.905
34.950
(
1.625
1.624
41.275
41.250
(
Modifications are available- see SAB Modification Section
Keyway*
.25 x .12
(6.35 x 3.18)
)
.31 x .16
(7.94 x 3.97)
)
.38 x .19
(9.52 x 4.76)
)
Shaft
Length (AH)
2.62
(66.68)
3.12
(79.38)
3.75
(95.25)
Ratings
Character Voltage Hz
B 115 60 D 110 50 E 200 60
230
F
190
H 220 50
460
L
380
M 415 50 N 575 60 O 110/220 50 P 115/230 60
230/460
Q
230
R 200/400 60
60 50
60 50
60 50
Direct Current
Character Voltage
T U V
W
X Y Z
Consult factory if other DC voltage is needed
12 24 36 48
95 115 230
47