Stearns 1-056-8XX Catalog Page

Series 56,800 (1-056-8XX)
Division 2 Hazardous Location Mounting Face: NEMA 56C, 143TC and 145TC
4.5” AK, 5.88” AJ
BACK TO T ABLE OF CONTENTS
Static Torque: 1.5 through 25 lb-ft Enclosure Material: Cast Iron Release Type: Side Lever, maintained with
auto reset
Enclosure Protection: Type 4/IP 56 Certified: UL Listed, File E 14893 for
Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell. The acceptability of the brake and motor combination must be determined by Underwriters Laboratory.
Universal Mounting: Through 15 lb-ft. 20 and 25 lb-ft. supplied with springs for vertical modification.
Epoxy Encapsulated Coil Construction, with Class H Insulation
NC Thermostat
Maximum speed: Horizontal 5000 rpm Vertical 3600 rpm
Installation, Service and Parts List: P/N 8-078-905-18
ABS Type Approval Certified Brake set and release times in
milliseconds, when brake and motor are switched separately (for T1/T2 definitions,
see page 101):
Static
Torque
1.5 - 25
Coil Size T1 T2
4, K4,
K4+, M4+
25 14
40
Dimensions for estimating only. For installation purposes request certified prints.
Motor Frame Adapters
WARNING! Before selecting an adapter to mount a brake on a larger motor frame, the torque and thermal capacity required by the application should be determined as shown in the “Selection Procedure” section. A larger motor may indicate a requirement for greater thermal capacity than the brake is designed for. The brake selection must be matched to the motor and application requirements, before use of an adapter is considered.
To Adapt to NEMA
Frame
Size
182TC 184TC 213TC 215TC 254TC 256TC
For adapter dimensions, see Technical Data.
AK
Dim.
in.
(mm)
8.50
(215.90)
8.50
(215.90)
Reg.
No.
Brake
Torque
Adapter
Stock
Number
5-55-5041-001.5-6-9
5-55-5043-0010-25-9
Additional
Shaft Length
Required
in.
(mm)
.94
(23.81)
.94
(23.81)
Dimensions
Model
Number
1-056-812-00
1-056-822-00
1-056-832-00
1-056-842-00
1-056-852-00
1-056-862-00
Static Torque
Nominal
(lb-ft)
(Nm)
3
(4)
6
(8)
10
(14)
15
(20)
20
(27)
25
(34)
Dimensions in Inches
(Dimensions in Millimeters)
AAGCG
4.7
.59
1.18
(119.4)
4.7
(119.4)
4.7
(119.4)
4.7
(119.4)
4.7
(119.4)
4.7
(119.4)
(15.0)
.59
(15.0)
.59
(15.0)
.59
(15.0)
.59
(15.0)
.59
(15.0)
(30.0)
1.18
(30.0)
1.18
(30.0)
1.18
(30.0)
1.18
(30.0)
1.18
(30.0)
1.66
(42.2)
1.66
(42.2)
1.66
(42.2)
1.66
(42.2)
1.66
(42.2)
1.66
(42.2)
Enclosure
IP 56 15
IP 56 15
IP 56 17
IP 56 17
IP 56 21
IP 56 21
Wt. lbs
(kg)
Series 56,800 continued
BACK TO T ABLE OF CONTENTS
Engineering Specifications
lb-ft
1.5
(2)
(4)
(8)
10
(14)
15
(20)
20
(27)
25
(34)
3
6
No. of Friction
Discs
1 4 7.5
2 4 7.5
2 4 7.5
2 K4 7.5
2 K4+ 7.5
3 K4+ 7.5
3 M4+ 7.5
Coil Size
AC
Maximum
Cycle Rate 1
cycle/min
Solenoid
AC Horizontal
Thermal
Capacity 2 hp-sec/min
(watts)
3.5
(43.50)
3.5
(43.50)
3.5
(43.50)
3.5
(43.50)
3.5
(43.50)
3.5
(43.50)
3.5
(43.50)
Inertia (Wk2)
2
lb-ft
(kgm2 x 10-4)
.008
(3.36)
.014
(5.88)
.014
(5.88)
.014
(5.88)
.014
(5.88)
.020
(8.40)
.020
(8.40)
Nominal
Static
Torque
(Nm)
1
Maximum solenoid cycle rate is based on ambient temperature of
104°F (40°C) with 50% duty cycle. Does relate to brake cycle rate (see Thermal Capacity).
2
Thermal capacity rating is based on ambient temperature of 104°F (40°C), stop
time of one second or less, with no heat absorbed from motor. Derate thermal capacity by 25% for vertical mounting. Refer to Selection Procedure Section.
Current Ratings (amperes)
Solenoid Coil Size
4
K4 K4+ M4+
AC
Current
Inrush
Holding
Inrush
Holding
Inrush
Holding
Inrush
Holding
Voltage: 60 Hz
200
115
Vac
Vac
2.1
3.6 .2
.3
2.5
4.3 .2
.3
2.5
4.6 .2
.4
2.5
4.6 .2
.4
230 Vac
1.8 .2
2.2 .2
2.3 .2
2.3 .2
400 Vac
1.1 .08
1.3 .1
1.2 .1
1.2 .1
460 Vac
.9 .08
1.1 .08
1.0 .1
1.0 .1
575 Vac
.7 .06 .9 .07 .9 .08 .9 .08
Ordering and Identification Information
The following example and tables provide information for selecting the appropriate three-letter suffix when ordering a Stearns Brake. Example of a complete part number: 1-056-832-00-BFF Lead wire position (internal and external, left and right)
230 Vac 5/8 bore and 3/16 x 3/32 keyway
Voltage: 50 Hz
220
110
Vac
Vac
2.1
4.1 .2
.3
1.9
3.8 .2
.4
2.0
4.9 .2
.4
2.0
4.1 .2
.4
380 Vac
.9 .08
1.1 .08
1.0 .1
1.3 .1
Hub Selection
Bore
Character
A*
B C D E
F*
K
L* N* O* P* R* S*
Maximum allowable bore 1.25. For thru-shaft applications, .875 is maximum.
(in.)
5/8 5/8 3/4
7/8 1-1/8 1-1/4
1/2
1
9/16
11/16
1-1/6
13/16 15/16
Keyway**
(in. x in.)
1/8 x 1/16 3/16 x 3/32 3/16 x 3/32 3/16 x 3/32
1/4 x 1/8 1/4 x 1/8
1/8 x 1/16
1/4 x 1/8
1/8 x 1/16 3/16 x 3/32
1/4 x 1/8
3/16 x 3/32
1/4 x 1/8
* These bores are non-standard. ** Keyseats made to ANSI B17.1 standard.
Standard AC Voltage Ratings
Character Voltage Hz
B 115 60 D 110 50 E 200 60
230
F
190
H 220 50
460
L
380
M 415 50 N 575 60 O 110/220 50
115
P
230
230/460
Q
190/380
R 200/400 60
DC voltages not available.
Modifications are available- see SAB Modification Section
60 50
60 50
60
60