Stearns 1-048-1XX Catalog Page

Series 48,100 (1-048-1XX)
Mounting Face: 48C
3.0” AK, 3.75” AJ
Static Torque: 1.5 through 6 lb-ft Enclosure: IP23 (formerly referred to by
Stearns as NEMA 2), Stamped Steel Housing
Release Type: Side Lever
P/N 8-078-924-06 Parts List: P/N 8-078-914-02
BACK TO T ABLE OF CONTENTS
• Adjustable Torque
• Manual Wear Adjustment
• Side Manual Release Lever with Automatic Reset
• Class B Coil Insulation
• Spring-Set Electrically Released
• Lead Wire Length: 24 inches
• Maximum Speed: Horizontal 5000 rpm
• Certified: CSA File LR-6254.
Specifications
Nominal
Static
Torque
Maximum solenoid cycle rate is based on ambient temperature of 72°F (22°C) with 50% duty
1
Thermal capacity rating is based on ambient temperature of 72°F (22°C), stop time of one
2
Number of
Friction
lb-ft
(Nm)
1.5
(2)
3
(4)
6
(8)
cycle. Does not relate to brake cycle rate (see Thermal Capacity). second or less,
mounting. Refer to Selection Procedure Section.
Discs
with no heat absorbed from motor. Derate thermal capacity by 25% for vertical
Coil Size
AC DC
4 4
K4
Maximum
Solenoid
Cycle Rate
cycles/min
DCAC
4041
20 20
36K41
20
36M41
1
hp-sec/min
Thermal
Capacity 2
(watts)
4
(50)
4
(50)
4
(50)
Inertia (WK2)
2
lb-ft
(kgm2 x 10-4)
.003
(1.26)
.003
(1.26)
.003
(1.26)
Ordering and Identification Information
The following example and tables provide information for selecting the appropriate three­letter suffix when ordering a Stearns Brake.
Example of a complete part number: 1-048-161-XX-BP Lead wire position
Series Torque
Enclosure
00= Internal and
external leadwire position
01= Internal only
does not apply 115/230 Vac
5/8 bore and 3/16 x 3/32 keyway
Current Ratings (amperes)
Coil
Current
Size
Inrush
4
Holding Inrush
K4
Holding Inrush
M4
Holding
Modifications are available- see SAB Modification Section
Dimensions for estimating only. For installation purposes request certified prints.
Unit Data
Voltage: 60 Hz
230
115
Vac
Vac
1.8
3.6
.2
.3
2.2
4.3
.2
.3
1.5
3.0
.3
.6
Number*
1-048-151-00-XX
1-048-151-01-XX
1-048-161-00-XX
1-048-161-01-XX
1-048-171-00-XX
1-048-171-01-XX
575
460
Vac
Vac
.7
.9
.06
.08
.9
1.1
.07
.08
.6
.8
.1
.1
Model
Nominal Static
Hub Selection
Bore
Char-
acter
A* C*
Maximum allowable bore .750.
For through-shaft applications .625 is maximum
* These bores are non-
standard.
** Keyseats made to
ANSI B17.1 Standard.
(in.)
Keyway**
(in. x in.)
1/8 x 1/165/8 3/16 x 3/325/8B 3/16 x 3/323/4
1/8 x 1/161/2K
Torque
(lb-ft)
(Nm)
1.5
(2)
1.5
(2)
3
(4)
3
(4)
6
(8)
6
(8)
Weight
Standard AC Voltage Ratings
Includes DC electronic switch (polarized).
lbs
(kg)
4.6
(2.1)
4.6
(2.1)
4.6
(2.1)
4.6
(2.1)
(2.3)
(2.3)
F
L
Q
5
5
* Eighth and
Ninth positions designate lead wire position: 00 =internal and external 01 = internal only.
230 190
460 380
208-230/460
190/380
HzVoltageCharacter
60115B 50110D 60200E 60
50 50220H 60 50 50415M 60575N 50110/220O 60115/208-230P 60 50 60200/400R