State GS6 40 YRVIT L User Manual

RESIDENTIAL
SELECT
SL
HOT SURFACE IGNITION POWER VENT RESIDENTIAL GAS WATER HEATERS
®
Side-Mounted Taps Designed for Potable Recirculating Systems
• Suitable for potable water heating and space heating
Hydronic Installations
• Power vent water heaters are designed for use with hydronic air handlers, radiant floor heating or other applications requiring a recirculating hot water loop
PowerVentDesign
• No chimney required, vents through outside wall or roof
• Quiet modular blower for power venting up to 115’ with 3” pipe and one elbow, vents up to 155’ with 4” piping and one elbow
FVIR Compliant Design
• The 40 and 50-gallon models feature patented FVIR Compliant design and meet ANSI Z21.10.1-4.1 CSA standards for flammable vapor ignition resistance
*
Intelli-Vent™Gas Control
• Equipped with the energy-saving hot surface ignitor, and advanced electronics for more precise control of water temperature and easy-to-understand system diagnostics
110/120 Volt Electrical System
• Rating 3 amps or less, with 6-foot cord, standard 3-prong male connector
Dual Magnesium Anode Rods
• For extra protection against corrosion (models with 3/4” inlet and outlet)
Drain Valve
•Durable, Temper-Brass Drain Valve
UL Listed
Maximum Hydrostatic Working Pressure 150 PSI
CSA Certified and ASME Rated T&P Relief Valve, Factory-Installed
Green Choice
®
“Eco-Friendly”
Gas Burner
• Patented design reduces NOx emissions by up to 33% compared to standard burners
Longer Lasting PEXAN
Cold Water Tubes
• Cold water dip tubes are made from Everlast PEXAN™a cross-linked PEX polymer that can withstand long-term exposure to water temperatures up to 400°F
6-Year Limited Tank and Parts Warranty
®
For more information on Select®SL contact:
State Water Heaters 500 Tennessee Waltz Parkway Ashland City, TN 37015
1-800-365-0024 Toll-free USA www.statewaterheaters.com
Revised May 2012
*Intelli-Vent
Code Compliance - All models meet the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of 1992 and the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. Also complies with the current editions of the B.O.C.A. National Codes, C.E.C., U.B.C., S.B.C.C., C.A.B.O. and the H.U.D. standards.
is a registered trademark of Emerson Electric Company
SRGSS03911
RESIDENTIAL
SELECT®SL – HOT SURFACE IGNITION POWER VENT RESIDENTIAL GAS WATER HEATERS
90°F
ENERGY
MODEL
NUMBER
GS6 40 YRVIT L 38 .65 50,000 78% 39,000 51 63 55 20 1/2 13 8 49 14 1/2 49 170
GS6 50 YRVIT L 48 .65
GS6 50 YRVIT L5 50 .65
GS6 75 YRVIT L 74 N/A
Recoveries are based on natural gas BTU rate and are rounded to nearest gallon All models have standard 2” foam except GS6 75 YRVIT L (this model has 1 1/2” foam) When ordering propane, change “ Propane rate is 55,000 BTUH - Output is 43,500
GALLON
CAPACITY
Y
” to “H” in the model number (Example: GS6 40 HRVIT L)
FAC TOR
(EF)
BTU INPUT PER HOUR
NATURAL
50,000 79% 39,500 54 65 56 1/4 22 13 8 50 1/4 14 1/2 50 1/4 190
62,500 79% 49,400 64 65 56 1/4 20 13 8 50 1/4 14 1/2 54 190
80,000 80% 64,000 77 66 63 25 1/2 15 16 50 1/4 15 1/2 50 1/4 250
RECOVERY
EFFICIENCY
BTU OUTPUT
PER HOUR
NATURAL
RECOVERY
RISE
(GPH)
DIMENSIONS IN INCHES
A B C D E F G H
APPROX.
SHIPPING
WEIGHT
(LBS)
Venting System Requirements
The Power Vent is designed to use Schedule 40 ABS, PVC or CPVC pipe installed with 0” clearance from combustible materials. This permits many venting options when the following requirements are observed. Venting requirements include:
• The water heater must have an independent vent system from the water heater to the exterior of the building
• Venting CANNOT be connected to existing vent piping or chimney.
• Venting MUST terminate horizontally through a side wall or vertically through the roof to the outdoors.
• USE ONLY ABS, PCV, or CPVC Schedule 40 pipe and fittings.
MODEL
NUMBER
GS6 40 YRVIT L 50,000 40’ 120’ 160’
GS6 50 YRVIT L 50,000 40’ 120’ 160’
GS6 50 YRVIT L5 62,500 N/A 80’ 120’
GS6 75 YRVIT L 80,000 N/A 30’ 100’
40 and 50-gallon models are supplied with 2”, 22-1/2” Termination Elbow, plus 2”, 3” and 4” screens. 74-gallon model is supplied with 3”, 90° Termination Elbow, plus 3” screen. 2” and 3” elbows are equal to 5’ of vent pipe. 4” elbows are equal to 8’ of vent pipe. Important: Read and follow requirements shown in the product manual for select Power-Vent gas clearances required to provide adequate combustion and proper ventilation.
BTU INPUT
MAXIMUM VENT DISTANCE
(Total Equivalent Feet)
2” PIPE 3” PIPE 4” PIPE
Optional Circulating Loop Fittings Package, Part No. 9002604005
Circulating Loop Fittings Package includes assembled di-electric unions and full port shut-off valves. A standard hose-connect drain valve is included for field installation. Specially designed for use on side tap recirculating water heaters. Kit must be ordered through Service Parts Department by calling 1-800-821-8017.
Domestic Plumbing Connections
• 40 and 50-gallon – 3/4” Male, NPT
• 75-gallon – 1” Male, NPT
Electrical Requirements
• 120 Volt - Maximum AMP draw is 2 AMPS or less.
For complete information on limited warranties, consult written warranty or contact technical support at 1-800-365-0024.
State Industries, Inc., reserves the right to make product changes or improvements without prior notice.
For more information on Select®SL contact:
State Water Heaters 500 Tennessee Waltz Parkway Ashland City, TN 37015
1-800-365-0024 Toll-free USA www.statewaterheaters.com
SRGSS03911 © 2012State Industries, Inc. Printed in U.S.A