State GS6 40 YBVIS User Manual

Designed for installation ease. Built for durability.
The State Power Vent water heaters feature
State developed the Power Vent to
go in easy and work hard. We designed
engineering to maximize efciency and deliver up to a .70 Energy Factor (EF) that meets the latest ENERGY STAR® qualications.
it with a 3-position rotatable blower
for more installation exibility—to
t any physical application. Then we
built it to vent using polypropylene, ABS,
180 feet. And we located all serviceable
components within 90 degrees of the
front of the unit for easy access. Plus,
we included the durable components
and features you’d expect to nd in
every State water heater. Built tough,
but easy to install.
Easy-install features:
• A versatile Power Vent design with an exclusive 3-position rotatable blower to adapt to limited space installations.
• Combined horizontal and vertical vent runs up to 125 equivalent feet with 3˝ diameter venting (180 equivalent feet with 4˝ venting on high-input 50- and 75-gallon models).
• Factory-installed, CSA-certied and ASME-rated T&P relief valve and a durable, tamper-resistant brass drain valve are positioned to simplify service and installation.
Other outstanding features:
• All models meet ENERGY STAR® requirements and may also qualify for local utility and rebate programs.
• PEXAN™ polymer dip tube optimizes inlet water pressure to minimize cold water regions within the tank. The self-cleaning action also reduces sediment accumulation on the bottom of the tank.
• Hot-surface ignitor is more robust and reliable than standing pilot, and reduces energy consumption.
• Factory-installed built-in heat traps on the water inlet and outlet reduce the amount of heat lost through piping.
• Environmentally-friendly 2-inch-thick foam insulation reduces the amount of heat loss and maximizes efciency.
• Models available with 3/4˝ side connections for combination (space heating) applications (side connections standard on high-input 50 and 75-gallon models).
• All models are equipped with a protected ammable vapor (FV) sensor that detects the presence of ammable vapors and automatically disables the burner to prevent their ignition.
• Air intake snorkel elevates the combustion air inlet to prevent ammable vapors from entering the sealed combustion chamber and igniting.
• Eco-friendly Green Choice by up to 33%.
• State-of-the-art electronic gas control ensures more precise temperature control and features an LED indicator to provide operation status and diagnostic information.
®
gas burner reduces NOx emissions
A
A
Exclusive 3-position rotatable blower for height-restricted installations
B
Front-mounted blower junction box for easy access
C
Accessible anode allows for servicing without removal of blower
D
B
C
D
G
Air intake snorkel prevents ammable vapors from entering the combustion chamber
H
Combustion chamber does not require ame arrestor
G
2-inch-thick foam insulation maximizes energy efciency
E
Exclusive electronic gas control delivers precise temperature control
F
PEXAN™ polymer dip tube reduces sediment build-up and improves energy efciency
E
F
H
Available in natural gas and propane. 6-year limited tank and parts warranty.
POWER VENT
Dimensions
Model
Number
Series Height To
Top Of
Blower
Height To
Top Of
Tank
Diameter Overall
Depth
Height
To
Drain
Height
To
Gas Inlet
Height To T&P
Height To
Upper Side
Connect
Height To
Lower Side
Connect
A B C D E F G G H lbs.
GS6 40 YBVIS GS6 40 YRVIT GS6 50 YBVIS GS6 50 YRVIT GS6 50 YRVHSL GS6 75 YRVHTL
All dimensions in inches. Natural gas models cited are Series 200. Propane models are Series 201. For propane models, change “Y” to “H” in the model number. All models rated for installation at altitudes up to 10,100 ft.
200 59 49 200 68 1⁄2 59 1⁄4 20 27 1⁄8 11 14 1⁄4 53 1⁄8 53 1⁄8 15 1⁄4 176 200 60 1⁄8 50 3⁄4 24 31 1⁄8 11 14 1⁄4 43 3⁄4 N/A N/A 198 200 68 1⁄8 58 3⁄4 22 29 1⁄8 11 14 1⁄4 51 3⁄4 51 3⁄4 15 1⁄4 192 200 61 1⁄8 52 24 31 1⁄8 11 14 1⁄4 44 1⁄2 44 1⁄2 15 1⁄4 212 200 70 5⁄8 61 1⁄4 26 33 1⁄8 11 14 1⁄4 53 53 15 1⁄4 277
5
8 22 29 1⁄8 11 14 1⁄4 42 1⁄2 N/A N/A 174
Specications
Model Number Gallon
Capacity
Input
BTU/h
Energy Factor First Hour Rating
USG
Recovery 90°F/50°C RISE
GPH
Shipping
Weight
GS6 40 YBVIS 40 40,000 0.70 73 44.7 GS6 40 YRVIT 40 50,000 0.70 90 55.9 GS6 50 YBVIS 50 40,000 0.70 90 44.7 GS6 50 YRVIT 50 50,000 0.70 96 55.9 GS6 50 YRVHSL 50 62,000 0.70 110 69.3 GS6 75 YRVHTL 75 72,000 0.68 155 80.4
Vent Lengths
For Technical Information and Automated Fax Service,
call 800-365-0024. State Water Heaters reserves the right to make
product changes or improvements without prior notice.
State Water Heaters
500 Tennessee Waltz Parkway
Ashland City, TN 37015
800-365-0024 Toll-free USA
statewaterheaters.com
Model
Number
GS6 40 YBVIS GS6 40 YRVIT GS6 50 YBVIS GS6 50 YRVIT GS6 50 YRVHSL GS6 75 YRVHTL
Maximum Vent Length
(eq. ft.)
Ø2˝ Ø3˝ Ø4˝
50´ 125´ 180´ 50´ 125´ 180´ 50´ 125´ 180´ 50´ 125´ 180´ N/A 50´ 125´ N/A 50´ 125´
SRGBR00813 April 2013R
Loading...