POWER DIRECT VENT RESIDENTIAL
GA S WAT E R H EAT ER S
®
Side-Mounted Taps
for Recirculating Systems
• Hot and cold “side taps” allow the
Power Vent DV to be used for
“combination” systems for water
heating plus space heating,
radiant floor heating or other
applications requiring a recirculating
hot water loop
Plugs for recirculating taps are
•
factory-installed
PowerDirectVentDesign
• Power Direct Vent residential gas
models are FVIR Compliant and
meet the ANSI Z21.10.1-CSA 4.1
standards
• Two pipe “Closed-Combustion”
system - draws combustion air from
outside and vents to outside the
home. Quiet, modular blower for
power venting with 3” Schedule 40
PVC, CPVC or ABS piping.
Energy Saving Hot
Green Choice Burner
• Reduces NOx emissions up to 33%
and meets low NOx emission requirements
of less than 40 ng/j
PEXAN™ Diffuser Dip Tube
• Helps reduce lime and sediment buildup,
maximize hot water output
• PEXAN cross-linked polymer withstands
long-term exposure to temperatures
up to 400
Silencer™Heat
Trap Nipples
• Factory-Installed on all models. Helps
prevent heat from escaping from the
tank during standby periods.
CSA International Certified
ECO (Energy Cutoff)
Surface Ignition System
Maximum Hydrostatic
110/120 Volt
Electrical System
• Rating 3 amps or less, with 6 foot
cord, standard 3-prong male connector
Dual Magnesium
Anode Rods
• Provides extra protection
against corrosion
Brass Drain Valve
• Durable, tamper-resistant brass
®
drain valve
Code Compliance - All models meet the Federal Energy Efficiency Standards
effective January 20, 2004, according to the National Appliance Energy
Conservation Act (NAECA) of 1992 and the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and current edition of
ASHRAE/IESNA 90.1. Also complies with the current editions of the B.O.C.A.
National Codes, C.E.C., U.B.C., S.B.C.C., C.A.B.O. and the H.U.D. standards.
Working Pressure
150 psi
CSA Certified and ASME
Rated T&P Relief Valve,
Factory-Installed
6-Year Limited Tank and
Parts Warranty
®
o
F
FormoreinformationonSelect®SL contact:
State Water Heaters
500 Tennessee Waltz Parkway
Ashland City, TN 37015
1-800-365-0024 Toll-free USA
www.statewaterheaters.com
Revised May 2012
SRGSS03811
SELECT®SL — POWER DIRECT VENT
RESIDENTIAL GAS WATER HEATERS
RESIDENTIAL
90°F
MODEL
NUMBER
GALLON
CAPACITY
ENERGY
FAC TOR
(EF)
FIRST
HOUR
RATING
RECOVERY
RISE
(GPH)
BTU INPUT
PER HOUR
NAT/PROPANE
BTU OUTPUT
PER HOUR
NAT/PROPANE
DIMENSIONS IN INCHES
A B C D E F G H
GS6 40 YBPDT L 40 .60 70 41/37 40,000/36,000 30,400/27,360 57 48 1/2 21 15 8 42 17 42 224
GS6 50 YRPDT L5 50 .58
GS6 75 YRPDT L 75 .58
First hour ratings & recoveries are rounded to nearest gallon
All models have 3/4˝ male inlet and outlet connections
When ordering propane, change “
Y
” to “H” in the model number (Example: GS6 40 HBPDT L)
105 64 59 65,000/60,000 47,450/43,800 69 1/2 61 21 15 8 54 1/2 17 54 1/2 232
130 72/67 70,000/65,000 53,200/49,400 71 1/2 61 1/2 26 1/4 15 1/2 8 54 1/2 17 54 1/2 352
Venting System Requirements
1
The water heater requires its own (separate) venting system.
2
Venting cannot be connected to existing vent piping or chimney.
3
Venting must terminate horizontally through side wall or vertically through the
/
1.5˝ min.
1
from top
of heater
to center
line of flue
3˝ VENT
C
E
4˝
roof to the outdoors.
4
For venting, 3˝ Schedule 40 PVC, CPVC, ABS pipe can be used.
5
Horizontal runs must be secured at 3 1/2´ intervals and vertical runs secured
BA
F
H
at 5´ intervals.
6
Vent piping cannot under any circumstances be run downhill.
7
Horizontal runs require a minimum 1/8˝ rise per 5 feet.
8
Total vertical and horizontal runs cannot exceed 45´ with one elbow.*
9
To comply with ANSI Standards install vent piping so that it can be visually in-
D
G
OPTIONAL 3” PVC HORIZONTAL VENT KIT
(Kit Number 9006475005)
spected.
10
Power Direct Vent terminal shall terminate at least “A” below, “A” horizontally
or “A” above any door, window or gravity air inlet into the building.
“A” = 9˝ (50,000 BTUH input or less) “A” = 12˝ (over 50,000 BTUH input)
11
For model number GS6 50 YRPDT L5, 5´ of 3˝ ABS vent pipe is supplied and
INSTALL IN ACCORDANCE WITH LOCAL CODES.
3” DIAMETER
VENT/EXHAUST
must be used for the first 5´ of the exhaust outlet vent system.
12
For model number GS6 75 YRPDT L, 5´ of 3˝ CPVC vent pipe is supplied and
must be used for the first 5´ of the exhaust outlet vent system.
*If more elbows are required, the venting distance must be reduced 5´ for every 90° elbow.
1 1/2”
OPTIONAL CONCENTRIC VENT KIT
4 1/2” DIAMETER
1 3/16”
3” DIAMETER PVC
INTAKE/COMBUSTION AIR
21 1/8”
39”
APPROX.
SHIPPING
WEIGHT
(LBS)
IMPORTANT! Combustion Air And Ventilation Requirements For Power Direct Vent Water Heaters
18˝minimum in all directions from any obstructions that may interfere with ventilation.
•
0˝clearance for 3˝ PVC, ABS or CPVC Schedule 40 piping from combustible surfaces.
•
12˝minimum from the ground and corners, 9˝ceiling overhangs.
•
The Power Direct Vent outlet terminal shall terminate at least 36˝above any forced air inlet located within 10 feet.
•
The Power Direct Vent outlet terminal of 50,000 BTUH input models or less shall terminate at least 9˝below, 9˝horizontally from or 9˝above any door, window or gravity
•
air inlet into the building.
The Power Direct Vent outlet terminal of over 50,000 BTUH input models shall terminate at least 12˝ below, 12˝horizontally from or 12˝above any door, window or grav-
•
ity air inlet into the building.
18˝ minimum from other natural draft (gravity) direct vent, power vent or power direct vent appliance inlet and/or outlet vent(s) when directly above or 135° to either
•
side of center line.
24˝minimum from any appliance inlet and/or outlet vents when directly below or 45° to either side of center line.
•
The location selection must provide clearances for servicing and proper operation of the water heater.
•
Vent termination must not be within 3 feet of any items such as gas meters, gas valves or other gas regulating equipment.
•
Optional Circulating Loop Fittings Package, Part No. 9002604
Circulating Loop Fittings Package includes assembled di-electric unions and full port shut-off valves. A standard hose-connect drain valve is included for field installation. Specially
designed for use on side tap recirculating water heaters. Kit must be ordered through Service Parts Department at 1-800-821-2017.
For complete information on limited warranties, consult written warranty or contact technical support at 1-800-365-0024.
State Industries, Inc., reserves the right to make product changes or improvements without prior notice.
For more information on Select®SL contact:
State Water Heaters
500 Tennessee Waltz Parkway
Ashland City, TN 37015
1-800-365-0024 Toll-free USA