These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the
manufacturer of all liability.
Star reserves the right to change specifi cations and product design without
notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specifi cations contained in this sheet are subject to change
without notice. While Star Manufacturing exercises good faith efforts to provide
information that is accurate, we are not responsible for errors or omissions
in information provided or conclusions reached as a result of using the
specifi cations. By using the information provided, the user assumes all risks in
connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model
number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure faster service.
Model No.
Authorized Service Agent
Reference the listing provided with the unit
Serial No.
Voltage
Purchase Date
or
for an updated listing go to:
Website: www.star-mfg.com
E-mail Service@star-mfg.com
Telephone: (800) 807-9054 Local (314) 781-2777
The Star Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time
Hours:
Telephone: (800) 807-9054 Local (314) 781-2777
Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive
St. Louis, MO 63143
U.S.A
2
2
SPECIFICATIONS
HPDE1, HPDE1H, HPDE1P, HPDE1HP
Capacity: Two 6 pound bags (Two 2.7 KG Bags)
Electrical: 120V, 60 hertz, single phase, 820 Watts; 7 amps
230V, 50/60 hertz, single phase, 820 Watts; 3.5 amps
Cord: 6 ft. length
Plug: 120V - NEMA 5-15P
230V - CEE7-7
Dimensions: 9 7/16" W x 20 7/16" D x 26 13/16" H (23.97 W x 51.91 D x 68.10 H cm)
Net Weight: 36 lbs. (16.34 KG)
HPDE2, HPDE2H, HPDE2P, HPDE2HP
Capacity: Four 6 pound bags (Four 2.7 KG Bags)
Electrical: 120V, 60 hertz, single phase, 1000 Watts; 8.5 amps
230V, 50/60 hertz, single phase, 1000 Watts; 4.5 amps
Cord: 6 ft. length
Plug: 120V - NEMA 5-15P
230V - CEE7-7
Dimensions: 14 5/16" W x 20 7/16" D x 26 13/16" H (36.35 W x 51.91 D x 68.10 H cm)
Net Weight: 50 lbs. (22.7 KG)
3
CAUTION
This commercial foodservice dispenser is suitable
for self-service applications solely for the purpose
of dispensing the food product contained within
the dispenser, provided the owner and operator
maintain the food product at a safe temperature
and condition and provide any necessary utensils,
trays, or other apparatus in a safe and convenient
location with appropriate instructions. This
appliance is not intended for repair, cleaning,
maintenance, loading and unloading of food
product, or other uses by non-trained employees
or the general public. This unit is not sold for
consumer use in and around the home.
-IMPORTANT-
Read this manual completely before attempting
installation.
INSTALLATION
This peristaltic dispenser is equipped for the
voltage and wattage indicated on the nameplate
mounted on the back of the unit, and is designed
for use on alternating current (AC) only.
5. Place the end of the tube in the slot of the bottom
bracket.
6. Slide the pump block towards the pump head.
7. Hook the tension spring onto the catch.
8. Route the tube through the hole in the tube cover
leaving 1/2" of the tube below the cover.
9. Dispense a small amount of product to insure
the tube is seated correctly, and the product is
fl owing.
WARNING
DO NOT CONNECT TO DIRECT
CURRENT (DC).
GENERAL OPERATING
INSTRUCTIONS
This heated dispenser is designed to be
used with a 9” x 18” (22.8 x 45.7cm) poly
bag with a 1 inch (2.5cm) outlet fitment.
The peristaltic dispenser is designed to be
used with 1/4 inch ID (.6cm) to 1/2 inch id.
(1.3cm) tubing with 1/16 inch (.16cm) wall
thickness.
The dispenser is designed with an adjustable
thermostat. It is designed to maintain a product
temperature in the range of 145°F to 162°F (60°C
to 72°C).
Loading Product:
1. Turn the dispenser OFF.
2. Unhook the tension spring from the catch.
3. Slide the pump block away from the pump
head.
4 Insert the new bag into tray making sure the
fi tment rests on the block track and route the
tube around the rollers.
(Note: Make sure the tube is not twisted)
PORTION CONTROL
This dispenser may be supplied with a portion
control timer. This portion control is based on a
time setting. Variations in product temperature
and consistency will affect the dispensed amount.
To insure a consistent portion, use product that
is at the correct temperature, 145°F to 160° (62°C
to 71°C).
To set portion:
1. Load preheated product bag into dispenser.
2. Dispense product until there is a steady fl ow.
3. Dispense the product into a clean container,
and measure the product to verify the dispensed
amount.
4. Using a small screwdriver, turn the control dial
located on the back panel clockwise for more
product and counterclockwise for less product.
5. Repeat steps 3 and 4 until the desired amount
is reached.
4
6
Operation Notes:
The dispenser is a holding cabinet not a warmer. It
is intended to hold the food product at no less than
140°F (60°C) and no more than 165°F (73°C) after
the food product has been pre-heated to a minimun
of 140°F (60°C).
The product should be preheated according to the
manufacturer's instructions. The product should be
a minimum of 140°F (60°C) before dispensing.
NOTE: To increase the evacuation, open the
dispenser and pull the product towards the
bottom of the bag and the outlet fi tment once
or twice during operation.
If the pump drips, or does not dispense product,
check to make sure the tube is routed correctly, the
spring is latched onto the catch.
If the product is not preheated, you can expect it
take 3 hours for the product to reach 140°F (60°C)
if it starts out at room tempurature. 5 Hours if it is
refrigerated, and much longer if frozen.
The digital temperature readout displays the cabinet
air temperature and will fl uctuate during normal
operation. The product temperature should be close
to the temperature setpoint, but the actual product
temperature should be checked periodically to ensure
proper operation.
CHECKING PRODUCT TEMPERATURE
If the product has not been pre-heated, it will take
at 3-5 hours before it will reach 140° (60°C).
1. Dispense at least 3 inches of product into an
insulated cup.
2. Without hesitation, insert the thermometer to the
bottom of the cup and stir the product gently with
the stem of the thermometer.
3. Position the tip of the thermometer in the center
of the product mass.
4. The temperature should read between 140°F
(60°C) and 165°F (73°C).
CHANGING FACTORY TEMP PRESET
The dispenser is preset at the factory for a
temperature of 150°F (65°C). If a different
temperature is required, the setpoint can be changed
in a range from 145°F to 162°F (60°C to 72°C).
To change the temperature:
1. Press SET. "SP" will appear in the display.
2. Press SET again. The temperature setpoint will
now be displayed.
3. Using the UP or DOWN buttons, set the
temperature to the desired value.
4. Press SET again to save the setting.
5. Press the SET and DOWN buttons together to
exit the programming mode.
NOTE: The tube cover must be in place for
proper operation.
IL12
CLEANING INSTRUCTIONS
To clean the peristaltic dispenser:
The stainless steel body is corrosion resistant, but
may corrode if not cleaned properly. The dispenser
should be cleaned with a soft cloth with mild soap
and water and wiped dry. Do not use detergents,
strong abrasives, or metal scouring pads on the
stainless steel panels.
The pump mechanism should not need cleaning
during normal use. If product should spill onto the
pump head, it can be removed for easy cleaning (see Removal & Cleaning Pump Head). Clean the parts in
a solution of mild soap and water using a soft cloth.
Dry parts before reassembling.
The spring can also be removed for cleaning by
removing the knob and retaining washer.
The dispenser is designed to operate 24 hours a
day. Once the product is placed in the dispenser it
should not be removed until the bag is empty, or the
holding period of the product has expired.
5
To remove and clean the pump head:
1. Open the door.
2. Remove the bag according to the instructions.
3. Unscrew the knob from the pump head.
4. Remove the pump head.
5. Slide the pump block out of the track.
6. If needed the rollers can also be disassembled
for cleaning.
Note: When installing the pump head onto the drive
shaft, make sure the pump head is fully seated onto
the square end of the drive shaft before installing
the knob.
WARNING: The drive shaft and pump head
could be damaged if the pump head is
installed incorrectly.
6
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.