Using any part other than genuine Star factory supplied parts relieves the
manufacturer of all liability.
Star reserves the right to change specifi cations and product design without
notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specifi cations contained in this sheet are subject to change
without notice. While Star Manufacturing exercises good faith efforts to provide
information that is accurate, we are not responsible for errors or omissions
in information provided or conclusions reached as a result of using the
specifi cations. By using the information provided, the user assumes all risks in
connection with such use.
These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model
number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure a faster service.
Model No.
Serial No.
Voltage
Purchase Date
Authorized Service Agent
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com
E-mail Service@star-mfg.com
Telephone: (800) 807-9054 Local (314) 781-2777
The Star Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time
Hours:
Telephone: (800) 807-9054 Local (314) 781-2777
Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive
St. Louis, MO 63143
U.S.A
2
SPECIFICATIONS
HPD1ARB, SPD1ARB
Capacity: One 160 ounce pouch
Electrical: 120V, 60 hertz, single phase, 750 Watts, 6.5 amps
Cord: 6 ft. length
Plug: 120V - NEMA 5-15P
Dimensions: 9-7/16" W x 19-9/16" D x 30-5/16" H (23.97 W x 49.69 D x 77.0 H cm)
Net Weight: 42 lbs. (19.1 kg)
SPD1HP
Capacity: One 160 ounce pouch
Electrical: 120V, 60 hertz, single phase, 750 Watts, 6.5 amps
Cord: 6 ft. length
Plug: 120V - NEMA 5-15P
Dimensions: 9-7/16" W x 19-9/16" D x 27-5/16" H (23.97 W x 49.69 D x 69.4 H cm)
Net Weight: 42 lbs. (19.1 kg)
3
GENERAL SAFETY INFORMATION
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and
experienced in its operation and is not sold for consumer use in and around the home nor for
use directly by the general public in food service locations.
Before using your new equipment, read and understand all the instructions & labels
associated with the unit prior to putting it into operation. Make sure all people associated with
its use understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed.
This unit has been tested and carefully packaged to insure delivery of your unit in perfect
condition. If equipment is received in damaged condition, either apparent or concealed, a
claim must be made with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is
unpacked, a request for inspection of concealed damage must be made with carrier within
15 days. Be certain to retain all contents plus external and internal packaging materials for
inspection. The carrier will make an inspection and will supply necessary claim forms.
NOTE: Read this manual completely before attempting installation.
GENERAL INSTALLATION DATA
This peristaltic dispenser is equipped for the voltage and wattage indicated on the nameplate
mounted on the back of the unit and is designed for use on alternating current (AC) only.
NOTE: The peristaltic dispenser should not be installed without the four-inch (10cm) legs provided
with the machine. The legs screw into the nuts on the bottom of the dispenser.
CAUTION
DO NOT CONNECT TO DIRECT CURRENT (DC).
GENERAL OPERATING INSTRUCTIONS
This heated dispenser is designed to be used with a 9” x 18” (22.8 x 45.7cm) poly bag with a
1 inch (2.5cm) outlet fi tment. The peristaltic dispenser is designed to be used with 1/4 inch ID
(.6cm) to 1/2 inch id. (1.3cm) tubing with 1/16 inch (.16cm) wall thickness.
The dispenser is designed with a preset non-adjustable thermostat. It is designed to maintain
a product temperature of 155°F +/- 10°F, This is not to be confused with the thermometer
temperature which will be different.
Loading Product:
1. Turn the dispenser OFF.
2. Unhook the tension spring from the catch.
3. Slide the pump block away from the pump head.
4. Insert the new bag into the tray making sure the fi tment rests on the block track and route
the tube around the rollers.
(NOTE: Make sure tube is not twisted.)
5. Place the end of the tube in the slot of the bottom bracket.
6. Slide the pump block toward the pump head.
7. Hook the tension spring onto the catch.
8. Route the tube through the hole in the tube cover leaving 1/2" of the tube below the cover.
9. Dispense a small amount of product to insure the tube is seated correctly and the product is
fl owing.
4
PORTION CONTROL
This dispenser is supplied with a portion control timer. This portion control is based on a time
setting. Variations in product temperature and consistency will affect the dispensed amount. To
insure a consistent portion, use product that is at the correct temperature (145°F to 160°).
To set portion:
1. Load preheated product bag into dispenser.
2. Dispense product until there is a steady fl ow.
3. Dispense the product into a clean container and measure the product to verify the dispensed
amount.
4. Using a small screwdriver, remove the round plug covering the adjustment knob located on
the front of the unit below the tube cover.
5. Turn the control dial clockwise for more product and counterclockwise for less product.
6. Repeat steps 3 and 5 until the desired amount is reached.
OPERATION NOTES
The product should be preheated according to the manufacturer's instructions. The product
should be a minimum of 140°F before dispensing.
The dispenser will not function correctly if the product is not at the correct temperature
.
CHECKING PRODUCT TEMPERATURE
The dispenser should be plugged in and turned on with product in the dispenser for a least 5
hours.
1. Dispense at least 3 inches of product into an insulated cup.
2. Without hesitation, insert the thermometer to the bottom of the cup and stir the product gently
with the stem of the thermometer.
3. Position the tip of the thermometer in the center of the product mass.
4. The temperature should read between 140°F and 165°F.
The dispenser is designed to operate 24 hours a
day. Once the product is placed in the dispenser
it should not be removed until the bag is empty or
the holding period of the product has expired.
NOTE: To increase the evacuation, open the
dispenser and pull the product toward the outlet
fi tment once or twice during operation.
If the pump drips or does not dispense product,
check to make sure the tube is routed correctly
and the spring is latched onto the catch.
NOTE: The tube cover must be in place for
proper operation.
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.