Star Manufacturing 502FA Operation Manual

Star Manufacturing International Inc.
10 Sunnen Drive St. Louis, MO 63143
Phone: (314) 781-2777 Fax: (314) 781-3636
2M-Z1436 Rev. B 6/25/02
STAR-MAX
ELECTRIC HOT PLATE
MODELS
and Operating Instructions
502A AND 502FA
Model 502A
Model 502FA
1
SAFETY SYMBOL
RETAIN THIS MANUAL FOR FUTURE REFERENCE
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
This symbol is intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
NOTICE
NOTICE
Star reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Refer to the authorized service center listing provided with the unit. The Star Service Help Desk (1-800-807-9054) is available during normal business hours to answer any questions that may arise. Please have your model number and serial number for faster service.
2
GENERAL OPERATING INSTRUCTIONS
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.
LOCATE THE UNIT
Do not install the unit closer than 1 inch from a side wall and/or closer than 1 inch from a rear wall.
LEVELING UNIT
Level unit by adjusting the (4) feet for accurate and perfect line up with other Star-Max series units.
CAUTION
The Star-Max models 502A and 502FA Electric Hot Plates are equipped for the voltage indicated on the nameplate mounted on the front panel. This unit is designed to operate on alternating current (A.C.), two wire single phase service only. DO NOT
CONNECT TO DIRECT CURRENT (D.C.).
Total Connected Load
502FA - at 240 Volts, Wattage is 5200.
at 208 Volts, Wattage is 3900.
502A - at 240 Volts, Wattage is 4200. at 208 Volts, Wattage is 3150.
INSTALLATION
For your protection, we recommend that a qualified electrician install this appliance. The electrician should be familiar with electrical installations and your local electrical requirements. The external wiring should be in conduit or an approved type of flexible cable and of suitable size to carry the load. The supply circuit should be properly fused and equipped with a means of disconnecting as required by local electrical code. The body of the hot plate should be grounded (Do not ground to a gas supply pipe). The connections are made in this unit at the pigtail leads located in the junction box on the back of the unit. To gain access to the pigtail leads remove cover on junction box.
OPERATING PROCEDURE
DO NOT INSTALL WITHOUT FEET.
CAUTION
USE ONLY FLAT BOTTOM PANS AND POTS! DO NOT USE RAISED BOTTOM UTENSILS OR BUCKETS! GOOD HEAT TRANSFER DEPENDS UPON GOOD CONTACT BETWEEN THE ELEMENT AND POT.
Two (2) heating elements are used. For the 502FA each element draws 2600 watts on 240 Volts and 1950 watts on 208 Volts. For the 502A each element draws 2100 watts on 240 Volts and 1575 watts on 208 Volts. Each element is controlled by an infinite position switch. The right control knob controls the rear cooking element and the left control knob controls the front cooking element. On "HI" the element delivers uninterrupted full heat. Between "LO" and "5" any desired amount of heat can be obtained between 6% and 60% of full heat.
Signal lights are provided above the control knobs to give a visual check if either one or both heating units are turned on.