STA-RITE JTACL1/2 HP, JTADL 3/4 HP, JTAEL 1 HP, JTAFL 1-1/2 HP, JTACL Owner's Manual

...
DURA-JET TUB PUMP
O W N E R’ S M A N U A L
INSTALLATION, OPERATION & PARTS
MODELS
1/2 HP 3/4 HP 1 HP 1-1/2 HP
JTACL JTADL JTAEL JTAFL
Sta-Rite Pool/Spa Group
293 Wright Street, Delavan, WI 53115
www.sta-ritepool.com
Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA
Printed in U.S.A. ©2003, Sta-Rite Industries, Inc.
S197 (Rev. 1/17/03)
This manual should be furnished to the end user of this pump; its use will reduce service calls and chance of injury and will lengthen pump life.
2
DURA-JET TUB PUMP
To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY!
The Sta-Rite ‘JT’ Series Tub Pump:
• Is designed to circulate hot water in jetted tubs.
• Is an excellent performer; durable, reliable.
• Drains completely to assure sanitation, meet IAPMO standards.
Table of Contents
Safety Instructions ........................................................................................3
Installation ....................................................................................................4
Electrical....................................................................................................5-6
Operation .....................................................................................................7
Pump Service................................................................................................8
Troubleshooting Guide .................................................................................9
Repair Parts List ..........................................................................................10
Warranty.....................................................................................................11
3
READ AND FOLLOW SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert
to the potential for personal injury.
warns about hazards that will cause death, serious personal in-
jury, or major property damage if ignored.
warns about hazards that can cause death, serious personal in-
jury, or major property damage if ignored.
warns about hazards that will or can cause minor personal injury
or property damage if ignored.
NOTICE indicates special instructions not related to hazards.
Carefully read and follow all safety instructions in this manual and on equip­ment. Keep safety labels in good condition; replace if missing or damaged.
Incorrectly installed or tested equipment may fail, causing severe injury or property damage.
Read and follow instructions in owner's manual when installing and operating equipment. Have a trained pool professional per-
form all pressure tests.
1. Do not connect system to a high pressure or city water system.
2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE all air is out of system before operating or testing equipment.
Before pressure testing, make the following safety checks:
• Check all clamps, bolts, lids, and system accessories before testing.
• Release all air in system before testing.
• Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing.
Water pressure for test must be less than 25 PSI (172 kPa).
• Water Temperature for test must be less than 100
o
F. (38oC).
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. Remove trap lid and retighten hand tight only.
NOTICE: These parameters apply to Sta-Rite equipment only. For non-Sta-Rite equipment, consult manufacturer.
IMPORTANT SAFETY INSTRUCTIONS
Always follow basic safety pre­cautions with this equipment, in­cluding the following.
To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently installed pool is con­structed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassem­bled for storage and reassembled to its original integrity.
SAVE THESE INSTRUCTIONS
4
INSTALLATION
Installation and wiring of pump should only be done by qualified, licensed personnel.
Pump mount must:
Be Solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.)
Be installed with pump suction inlet higher than tub suction fitting. (This al­lows pump to drain completely when tub is drained.)
Have pump suction below tub water level when pump is running.
Be protected from excess moisture.
Allow adequate access for servicing pump and piping.
Ventilation:
Provide adequate ventilation to prevent motor overheating.
For continuous running, motor hot air exhaust must be able to escape tub motor compartment.
Piping:
Use flexible or rigid PVC pipe for connections to pump.
Use at least 1-1/2" IPS pipe.
Fittings restrict flow; for best efficiency use fewest possible fittings.
Unions are provided. Use as follows for leak-free connections to pump:
1. ‘O’ Ring and sealing surfaces must be clean.
2. Assemble handtight only! (NO WRENCHES!)
3. NO pipe compound or Teflon tape on unions.
4. Bond pipe to unions with PVC cement.
Use PVC cement only in a well ventilated area away from flame; FOLLOW MANUFACTURER‘S INSTRUCTIONS!
Fittings:
Size and number of jets will have a major effect on jet action.
Typical installations use up to four 7/8" or 3/4" diameter jets or up to seven 1/2" diameter jets.
Tub fittings must meet International Association of Plumbing and Mechanical Officials (IAPMO) standards for jetted bathtubs. Use only non-entrapping suc­tion fitting or double suction.
Loading...