Sta-Rite Clean Clear Installation Manual

Clean & Clear
Cartridge Filter System Owner’s Manual
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
SECTION I. PUMP SAFETY INSTRUCTIONS………………………………………2 SECTION II. HOW YOUR FILTER WORKS………………………………………….3 SECTION III. INSTALLATION…………………………………………………………4 SECTION IV. INITIAL START-UP AND RESTART INSTRUCTIONS………………6 SECTION V. CLEANING THE FILTER………………………………………………..6 SECTION VI. CHECK VALVE INSTALLATION INSTRUCTIONS.…………………8
SECTION VII WINTERIZING THE FILTER…………………………………………....8
SECTION VIII. CLEANING THE HIGH FLOW MANUAL AIR RELIEF VALVE……..9 SECTION IX. TROUBLESHOOTING…………………………………………………...9 SECTION X. PUMP INSTRUCTIONS………………………………………………...10 SECTION XI. TECHNICAL DATA……………………………………………………..12
Pentair Pool Products, Inc.
1620 Hawkins Ave., Sanford, NC 27330 Tel 919-774-4151 Fax 919-774-4841
10951 West Los Angeles Ave., Moorpark, CA 93021 Tel 805-523-2400 Fax 805-530-0183
Important Notice
Before installing this product, read and follow all warning notices and instructions accompanying this filter. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call 1-888-263-7763 for free copies.
Rev. A 6/7/06 1
Attention Installer. This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment.
WARNING
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
P/N 56269900
SECTION I. PUMP SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
3. WARNING - Risk of Electrical Shock. Connect only to a grounding type receptacle protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI.
4. Do not bury the electrical cord. Locate the cord to minimize the abuse from lawn mowers, hedge trimmers, and other equipment.
5. WARNING – To reduce the risk of electrical shock, replace damaged cords immediately.
6. WARNING - To reduce the risk of electrical shock, do not use an extension cord to connect unit to electric supply; provide a properly located outlet.
7. CAUTION – For continued protection against possible electrical shock, this unit is to be mounted to the base in accordance with the installation instructions.
8. SAVE THESE INSTRUCTIONS.
WARNING
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g. LOCK RING, PUMP, FILTER VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.
1. BEFORE REPOSITIONING VALVES AND BEFORE BEGINNING THE ASSEMBLY, DISASSEMBLY, OR ADJUSTMENT OF THE LOCK RING OR ANY OTHER SERVICE OF THE CIRCULATING SYSTEM: (A) TURN THE PUMP OFF AND SHUT OFF ANY AUTOMATIC CONTROLS TO ENSURE THE SYSTEM IS NOT INADVERTANTLY STARTED DURING THE SERVICING; (B) OPEN AIR RELIEF VALVE; (C) WAIT UNTIL ALL PRESSURE IS RELIEVED.
2. WHENEVER INSTALLING THE FILTER LOCK RING FOLLOW THE CLEANING FILTER INSTRUCTIONS EXACTLY.
3. ONCE SERVICE OF THE CIRCULATING SYSTEM IS COMPLETE
FOLLOW THE INITIAL START SYSTEM RESTART INSTRUCTIONS EXACTLY.
4. MAINTAIN CIRCULATION SYSTEM PROPERLY. REPLACE WORN OR DAMAGED PARTS IMMEDIATELY (e.g., lock ring, pressure gauge, relief valve, o-rings, etc).
5.
BE SURE THAT THE FILTER IS PROPERLY MOUNTED AND POSITIONED ACCORDING TO THE INSTRUCTIONS PROVIDED.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Rev. A 6/7/06 2
P/N 56269900
SECTION II. HOW YOUR FILTER WORKS
WARNING
To reduce the risk of electrical shock, only connect to a GFCI protected receptacle. Failure to do so could result in an electrical shock to pool users, installers, or others, which can result in serious personal injury or death.
Your cartridge filter is designed to produce clear, sparkling water and operate for years with a minimum of maintenance when installed, operated and maintained in accordance with these instructions.
A. YOUR FILTER USES A CARTRIDGE ELEMENT TO REMOVE DIRT PARTICLES
FROM THE WATER.
1. Dirt is collected in the filter by the cartridge element as water flows through the filter. Water enters the filter through the filter inlet port and is distributed evenly through the cartridge element.
2. The dirt is removed by the cartridge fabric and the clean water flows through the filter outlet port and is returned to the pool through the piping or hoses.
B. AFTER A PERIOD OF TIME, DIRT WILL ACCUMULATE IN THE FILTER CAUSING A
RESISTANCE TO THE FLOW OF WATER THROUGH THE FILTER.
1. This resistance results in a diminished flow of water and a rise in the filter pressure. Eventually the filter will have removed so much dirt and the filter pressure risen to such a point that it will be necessary to clean your filter, see SECTION V. CLEANING THE FILTER.
2. The filter’s function is to remove suspended matter from the water and does not sanitize the water. For sparkling clear water, the water must be sanitized and as well as balanced.
3. Pool chemistry is a specialized area, and you should consult your local pool service specialist for specific details. In general, proper pool sanitation requires a free chlorine level of 1 to 2 PPM and a PH range of 7.2 to 7.6.
WARNING
Failure to operate your filter system or inadequate filtration can cause poor water clarity obstructing visibility in your pool. Pool water clarity may obscure objects in the water, which while swimming and diving could cause severe personal injury and death. Never swim in a pool with poor water clarity.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Rev. A 6/7/06 3
P/N 56269900
SECTION III. INSTALLATION
To install this filter system, you will need the following simple tools – a screwdriver, pliers,
and ½” wrench.
1. Carefully remove the equipment from the carton and check for any evidence of damage due to rough handling or shipping. If any of the equipment is damaged, immediately notify the organization where the equipment was purchased.
2. This filter should be mounted on a level concrete slab, preferable concrete poured in a form or on a platform constructed of concrete block or brick.
3. Position the filter tank on the mounting base so that the drain plug is oriented away from the motor mount side of the base. Secure the tank to the base with two (2) 5/16-18 bolts.
4A. For Dynamo Pumps: Place the pump on the base with the lint pot to the same side as the
Inlet port of the tank. Secure the pump to the base with two (2) 5/16-18 bolts. See Diagram 2.
4B. For OptiFlo Pumps: Place the pump on the base with the lint pot to the same side as the
Outlet port of the tank. Secure the pump to the base with two (2) 5/16-18 bolts. See Diagram 3.
5. Install the connector hose, Item 15 on page 11, to the inlet port of the tank, tightening the union nut that is attached to the tank, only hand tight. Bend the hose 90 degrees to fit the threaded union nut over the outlet port of the pump. Hand tighten only.
6. Insert the check valve into the outlet port of the filter, making sure the rubber diaphragm is facing outward, see Diagram 1.
7. Install the union elbow adaptor to the outlet port of the tank tightening the nut only hand tight. Secure the flex hose with a hose clamp. Tighten the clamp with a screwdriver. Connect the flex hose from the outlet side of the filter to the return fitting on the pool wall, using a hose clamp.
8. Screw the hose adaptor, item number 711006 on page 11, into the inlet port of the pump. This is the opening in the sidewall of the pump pot. Use Teflon tape on the threads and tighten no more than one (1) turn past hand tight. Connect the flex hose to this adaptor with a hose clamp and tighten with a screwdriver. Connect the hose from the inlet port of the pump to the skimmer, using a hose clamp.
9. Install the High Flow air relief valve to the top of the tank lid. See Diagrams 2 and 3,
Detail A. This is an O-ring seal that requires hand tightening only.
10. Install the pressure gauge in the ¼”NPT threaded hole in the tank lid, using Teflon tape on
the threads. See Diagrams 2 and 3, Detail B.
11. Never install a pump in this system that exceeds the maximum pressure of the filter. See
data label.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Rev. A 6/7/06 4
P/N 56269900
Detail A
Detail B Detail B
Detail A Connector
Hose Assy 170046
Connector Hose Assy 175015
Diagram 2 Diagram 3
(Installation of Dynamo Pump shown) (Installation of OptiFlo Pump Shown)
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Rev. A 6/7/06 5
P/N 56269900