STA-RITE CMH-136, CHH-137, CM2H-136, CH2H-137, CMH3-136 Owner's Manual

...
60 CYCLE “C” AND “CC” SERIES
CENTRIFUGAL PUMPS
FOR SWIMMING POOL USE
O W N E R’ S M A N U A L
INSTALLATION, OPERATION & PARTS
Sta-Rite Pool/Spa Group
293 Wright Street, Delavan, WI 53115
North America: 800-752-0183, FAX 800-582-2217 International: 262-728-5551, FAX: 262-728-4461, TELEX: ITT 4970245
www.sta-ritepool.com
Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA
Printed in U.S.A. © 2002, Sta-Rite Industries, Inc. S408 (Rev. 12/10/02)
This manual should be furnished to the end user of this pump; its use will reduce service calls and chance of injury and will lengthen pump life.
230/460V 200V
HP Medium Head High Head Medium Head High Head
3 CMH-136 CHH-137 CM2H-136 CH2H-137
CMH3-136 CHH3-137 CM2H3-136 CH2H3-137 CCMH-136S CCHH-137S CCM2H-136 CH2H3-137 CCMH3-136S CCHH3-137S CCM2H3-136 CCH2H3-137
5 CHJ-138
CCHJ-138 CHJ3-138 CH2J3-138 CCHJ3-138 CCH2J3-138
MODELS
2
C’ and
CC’ SERIES
CENTRIFUGAL PUMP and TRAP
To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY!
The Sta-Rite ‘C’ and ‘CC’ Series Centrifugal pump:
• Is designed for use with commercial swimming pools or as a centrifugal pump.
• Is an excellent performer; durable, reliable.
Table of Contents
Safety Instructions ........................................................................................3
Uncrating and Inspection..............................................................................4
Installation.................................................................................................4-6
Electrical....................................................................................................7-8
Operation .....................................................................................................9
Service .................................................................................................10-12
Troubleshooting Guide ...............................................................................13
Repair Parts List .....................................................................................14-15
Warranty.....................................................................................................16
3
READ AND FOLLOW SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert
to the potential for personal injury.
warns about hazards that will cause death, serious personal
injury, or major property damage if ignored.
warns about hazards that can cause death, serious personal
injury, or major property damage if ignored.
warns about hazards that will or can cause minor personal injury
or property damage if ignored.
NOTICE indicates special instructions not related to hazards.
Carefully read and follow all safety instructions in this manual and on equip­ment. Keep safety labels in good condition; replace if missing or damaged.
Incorrectly installed or tested equipment may fail, causing severe injury or property damage.
Read and follow instructions in owner's manual when installing and operating equipment. Have a trained pool professional
perform all pressure tests.
1. Do not connect system to a high pressure or city water system.
2. Use equipment only in a pool or spa installation.
3. Install pump with at least 2 hydraulically balanced main drains equipped
with correctly installed, screw-fastened, anti-entrapment certified covers. See Page 4.
4. Trapped air in system can cause explosion. BE SURE all air is out of system
before operating or testing equipment.
Before pressure testing, make the following safety checks:
• Check all clamps, bolts, lids, and system accessories before testing.
• Release all air in system before testing.
• Tighten Sta-Rite trap lids to 25 ft. lbs. (3.5 kg-m) torque for testing.
Water pressure for test must be less than 25 PSI (7.5 kg/cm
2
).
• Water Temperature for test must be less than 100oF. (38oC).
• Limit test to 24 hours. After test, visually check system to be sure it is ready
for operation. Remove trap lid and retighten hand tight only. NOTICE: These parameters apply to Sta-Rite equipment only.
For non-Sta-Rite equipment, consult manufacturer.
IMPORTANT SAFETY INSTRUCTIONS
Always follow basic safety pre­cautions with this equipment, in­cluding the following.
To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently installed pool is con­structed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassem­bled for storage and reassembled to its original integrity.
SAVE THESE INSTRUCTIONS
4
UNCRATING AND INSPECTION
Handle with care. Check items received against packing list to be sure that all equipment has
been received. Inspect for shipping damage. If found, file claim with carrier immediately.
Cleanup
Clean up all trash and other materials which will interfere with installation from foundation and surrounding area.
For easy assembly, make sure all threaded joints and mating surfaces are clean. If necessary, clean with wire brush and solvent.
To reduce danger of explosion and fire, do not use gasoline as a
cleaning solvent.
Remove all foreign material (packing, etc.) from pump and strainer.
INSTALLATION
Only qualified, licensed personnel should install pump and wiring.
Foundation
Foundation must:
Be Solid - Level - Rigid - Vibration free. Be provided with necessary hold-down bolts, washers, and shims. Allow pump inlet to be as close to water level as possible. Use short, direct suction pipe (to reduce friction losses). Locate pump below pool water level (pump is not self priming). Allow for shutoff valves in suction and discharge piping. Have adequate floor drainage to prevent flooding. Be protected from excess moisture. Allow adequate access and include suction and discharge (isolation) valves
for servicing pump and piping.
POOL PUMP SUCTION REQUIREMENTS
Pump suction is hazardous and can trap and drown or disem­bowel bathers. Do not use or allow anyone else to use a pool, spa, or hot tub unless it has at least two suction outlets to each pump suction line (see “Outlets Per Pump,” Page 5). Do not use or operate swimming pools, spas, or hot tubs if a suction outlet cover is missing, broken, or loose. Follow the
guidelines below for a pump installation which minimizes risk to users of pools, spas, and hot tubs.
Entrapment Protection
The pump suction system must provide protection against the hazard of suction entrapment or hair entrapment/entanglement.
Suction Outlet Covers
All suction outlet covers must be maintained. They must be replaced if cracked, broken, or missing.
See Page 5 for outlet cover certification requirements.
All suction outlets must have correctly installed, screw-fastened covers in place.
5
Outlets Per Pump
Provide at least two hydraulically balanced main drains, with covers (see above), for each swimming pool pump suction line. The centers of the main drains (suction fittings) must be at least three feet apart.
The system must be built so that it cannot operate with the pump drawing water from only one main drain (that is, there must be at least two main drains connected to the pump whenever it is running). (See Figure 1). However, if two main drains run into a single suction line, the single suction line may be equipped with a valve which will shutoff both main drains from the pump (see Figure 1).
More than one pump can be connected to a single suction line as long as the requirements above are met.
Water Velocity
If 100% of the pump’s flow comes from the main drain system, the maximum water velocity in the pump suction hydraulic system must be seven feet per second or less even if one main drain (suction fitting) is completely blocked. The flow through the remaining main drain(s) must comply with the latest ASME/ANSI Specification for Suction Fittings For Use in Swimming Pools,
Spas, Hot Tubs, and Whirlpool Bathtub Applications.
Piping – General
System piping must be at least equal to size of pump connections. To prevent strain on the pump casing and foundation, pipe and fittings must
be aligned to pump without forcing. To avoid strains on the pump, support both suction and discharge pipes
independently. Place these supports near the pump. To avoid a strain left by a gap at the last connection, start all piping at the
pump and run pipe away from the pump.
Figure 1 – Recommended pump suction layout.
Anti-entrapment
Cover, screw-fastened
to Main Drain Sump
Main Drain Main Drain
Valves OK between pump and Tee
At Least
3 Feet
No valves between Tee and Main Drains
Anti-entrapment
Cover, screw-fastened
to Main Drain Sump
Pump
2515 0497
Loading...