Installation Guide
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
READ, THEN KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
© 2009 Pentair Water Pool and Spa, Inc. All rights reserved
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 555-5000
StarGuard®, IntelliFlo®, Pentair Pool Products®, American Products®, Pentair Water Pool and Spa® are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.
P/N 510587 Rev B 12-15-09
Contents
WARNINGS and IMPORTANT SAFETY PRECAUTIONS......................................................ii
The Virginia Graeme Baker Pool and Spa Safety Act ............................................................vi
Acts Codes and Standards........................................................................................................vii
Hydraulic System Specifications................................................................................................1
Section 1
Field Fabricated Sump Installation..................................................3
Section 2
StarGuard® 8-inch Round Drain
Installation ........................................................................................ 4
P/N 500100 - 500109, 500140 - 500149
Section 3
StarGuard® 8-inch Round Drain Two Port (2” NPSM Side x 1-1/2 “ NPSM Bottom)
Installation ..........................................................................................7
P/N 500110 - 500114
I
Section 4
StarGuard® 8-inch Round Drain Single Port (2” NPSM Side)
Installation .......................................................................................10
P/N 500115 - 500119
Section 5
StarGuard® 8-inch Round Drain (Dual Bottom Ports)
Installation .......................................................................................13
P/N 500120 - 500129
Section 6
StarGuard® 8-inch Round Drain Two Port (for vinyl liner pools) (2” NPSC Side x 1-1/2” NPSC Bottom)
Installation .......................................................................................17
P/N 500130 - 500139
Required tools: No. 2 Philips head screwdriver and torque driver (in-lbs).
READ, THEN KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
StarGuard® 8-inch Round Main Drain Installation Guide
II
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT!
SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT IS NOT INSTALLED AND USED CORRECTLY.
THIS COVER MUST ONLY BE INSTALLED AND USED WITH THE SUPPLIED PENTAIR WATER POOL AND SPA® FRAME OR WITH AN EXISTING PENTAIR POOL PRODUCTS
®
OR AMERICAN PRODUCTS® FRAME THAT IS IN GOOD CONDITION AND HAS INTACT BRASS INSERTS. THIS COVER IS INCOMPATIBLE WITH ANY OTHER FRAME. IF THE POOL OR SPA HAS AN EXISTING FRAME (OTHER THAN ONE IN GOOD CONDITION WITH INTACT BRASS INSERTS MANUFACTURED BY PENTAIR POOL PRODUCTS OR AMERICAN PRODUCTS), THE EXISTING FRAME MUST FIRST BE REMOVED AND THE NEW SUPPLIED FRAME INSTALLED. DO NOT INSTALL THIS COVER ON ANY OTHER STYLE OF FRAME OR ANOTHER MANUFACTURER’S FRAME. FAILURE TO FOLLOW THIS WARNING MAY RESULT IN A SUCTION ENTRAPMENT HAZARD AND CAN CAUSE LIMB AND BODY ENTRAPMENT OR EVISCERATION.
FOR USE WITH MULTIPLE SUBMERGED SUCTION OUTLETS OR A SINGLE
SUBMERGED SUCTION OUTLET. IF ONLY A SINGLE SUCTION OUTLET OR MAIN DRAIN EXISTS, A SAFETY VACUUM RELEASE SYSTEM (SVRS) SUCH AS THE PENTAIR WATER POOL AND SPA INTELLIFLO® VS+ SVRS PUMP, A GRAVITY DRAINAGE SYSTEM, AN AUTOMATIC SHUT-OFF SYSTEM OR A SUCTION-LIMITING VENT SYSTEM MUST BE USED.
IMPROPER INSTALLATION OR USE OF THIS PRODUCT MAY PRESENT A RISK OF
HAIR OR BODY ENTRAPMENT AND DROWNING. INSTALL THIS EQUIPMENT IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED. USE ONLY WITH THE COMPONENTS AND MOUNTING HARDWARE PROVIDED. FAILURE TO FOLLOW THESE INSTRUCTIONS AND/OR USE WITH COMPONENTS NOT PROVIDED BY PENTAIR POOL PRODUCTS® AND INTENDED TO BE USED WITH THIS PRODUCT MAY RESULT IN IMPROPER POSITIONING OR FUNCTIONING OF DRAIN COVER AND MAY CAUSE SEVERE PERSONAL INJURY OR DEATH.
F
SUCTION ENTRAPMENT HAZARD
Pool and spa pumps produce high levels of suction, which can pose extreme danger if a person comes in close proximity to an open pool or spa drain or if a drain cover is loose, cracked, broken or missing.
Pool and spa pumps move large volumes of water, which can pose extreme danger if a person’s hair comes in close proximity to a drain that is not the proper size for the pump or pumps.
Suction entrapment dangers include:
Hair Entanglement – When the hair tangles or knots in the drain cover, trapping the swimmer underwater. This
hazard is present when the flow rating of the cover is too small for the pump or pumps.
Limb Entrapment – When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling. This hazard is present when a drain cover is missing, broken, loose, cracked or not properly secured.
Body Entrapment – When a portion of the body is held against the drain cover trapping the swimmer underwater. This hazard is present when the drain cover is missing, broken or the cover flow rating is not high enough for the pump or pumps.
StarGuard® 8-inch Round Main Drain Installation Guide
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
Evisceration/Disembowelment – When a person sits on an open pool (particularly a child wading pool) or
spa outlet and suction is applied directly to the intestines, causing severe intestinal damage. This hazard is present when the drain cover is missing, loose, cracked, or not properly secured.
Mechanical Entrapment – When jewelry, swimsuit, hair decorations, finger, toe or knuckle is caught in an opening of an outlet or drain cover. This hazard is present when the drain cover is missing, broken, loose, cracked, or not properly secured.
Use these fittings only with a pumping system rated for the corresponding flow or less for 2
inch plumbing (see sump diagram on page 5). FAILURE TO DO SO CAN RESULT IN HAIR OR BODY ENTRAPMENT WHICH CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. If in doubt about the rating of your system, consult a qualified pool or spa professional.
IMPORTANT NOTICE
Regularly inspect all drain covers for cracks, damage and advanced weathering. If a drain cover becomes loose, cracked, damaged, broken or is missing, close the pool or spa immediately, post a notice and keep the pool or spa closed until an appropriate VGB 2008 certified drain cover is properly installed. Drain covers deteriorate over time due to exposure to sunlight and pool chemicals. This drain cover must be replaced within seven (7) years from installation (or earlier if the cover becomes damaged in any way).
An ANSI/ASME A112.19.8a approved anti-entrapment drain cover must be used
for each drain. Pools and spas should utilize two drains per pump. If a drain cover becomes loose, broken or is missing, close the pool or spa immediately and shut off the pump until an approved anti-entrapment drain cover is properly installed with the supplied stainless steel screws. Only the supplied 316 stainless-steel screws should be used with the drain cover. Substitute screws such as masonry screws, sheet rock screws or other types of screws should never be used. Screws put into the frame anywhere except in the original screw holes will not hold and will allow the drain cover to come off the main drain, causing an entrapment hazard, including possible limb and body entrapment or evisceration/disembowelment. If the screw holes of the frame are stripped or the brass inserts are missing, loose, or damaged, replace the frame. DO NOT DRILL NEW SCREW HOLES IN THE FRAME AS THIS WILL DAMAGE AND WEAKEN THE FRAME.
III
IMPORTANT NOTICE
Attention Installer: This manual contains important information about the installation, operation and safe use of
this product. This information should be given to the owner and/or operator of this equipment. Please refer to www.pentair.com for all warnings and instructions related to the StarGuard® 8-inch Round Main Drain.
Before installing this product, read and follow all warning notices and instructions which are
included. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for additional free copies of these instructions. It is absolutely critical that the suction plumbing be installed in accordance with the latest national and local codes for swimming pools.
A pool/spa pump produces high levels of suction, which can pose extreme danger if a
person comes in close proximity to an open pool or spa drain or a loose or broken drain cover or grate.
Hydrostatic relief valve
For installations utilizing a hydrostatic relief valve, using a collector tube will maintain a clear path to the hydrostatic valve. At least one hydrostatic relief valve in a set of suction outlets will allow hydrostatic uplift pressure caused by ground water to be relieved into the pool or spa.
StarGuard® 8-inch Round Main Drain Installation Guide
IV
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
Entrapment Avoidance Notice:
The covers used on suction outlets should be approved and listed as conforming to the currently published edition of ANSI/ASME A112.19.8a Standard. These covers should be inspected regularly and replaced if cracked, broken or older than the design lifetime indicated on them by the manufacturer. The maximum possible flow rate of the pump should be less than or equal to the maximum approved flow rate indicated on the suction outlet cover by the manufacturer. THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN COVERS ARE MISSING, CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR ENTANGLEMENT, EVISCERATION AND DEATH.
Pumps improperly sized or installed or used in applications other than for which the pump was
intended can result in severe personal injury or death. These risks may include but not be limited to electric shock, fire, flooding, suction entrapment or severe injury or property damage caused by a structural failure of the pump or other system component.
The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia in
hot tubs and spas.
To reduce the risk of injury, do not permit children to use this product unless they are closely
supervised at all times.
When setting up pool water turnovers or flow rates the operator must consider local codes
governing turnover as well as disinfectant feed ratios.
DO NOT increase pump size; this will increase the flow rate through the system and exceed
the maximum flow rate stated on the drain cover.
StarGuard® 8-inch Round Main Drain Installation Guide
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
Most states and local codes regulate the construction, installation, and operation of
public pools and spas, and the construction of residential pools and spas. It is important to comply with these codes, many of which directly regulate the installation and use of this product. Consult the local building and health codes for more information.
Dual suction fittings shall not be located on seating areas or on the back rests for such seating areas.
If the pool or spa has only a single suction outlet or main drain, a Safety Vacuum Release System (SVRS) such as the Pentair Water Pool and Spa IntelliFlo® VS+SVRS pump, a gravity drainage system, an automatic shut-off system or a suction-limiting vent system MUST be used.
In the event one suction outlet is completely blocked, the remaining suction outlets serving the system shall have a flow rating capable of the full flow of the pump(s) for the specific system.
An approved anti-entrapment suction outlet cover must be used for each drain.
Never exceed the maximum flow rate stated on the drain cover.
Before each use of the facility the suction fitting, including fasteners, should be inspected for damage or tampering.
Close the pool or spa if any suction outlet component is loose, cracked, broken, missing or not securely attached. Replace loose, cracked, damaged, broken or missing drain covers.
In addition to two or more suction outlets per pump (Figure 2) installed in accordance with the latest APSP standards and CPSC guidelines, follow all applicable national, state and local codes.
The suction outlet to a swimming pool pump pulls a high vacuum. If pump is used with only one suction pipe, anyone blocking pump suction with hair or body will be trapped and held against the suction fitting. Disembowelment or drowning can result.
To prevent entrapment, install at least two suction outlet (main drains) fittings per pump in pool. Separate these outlets by either of the following procedures.
A. Locate the outlets at least three (3) feet apart.
B. Locate the outlets in two (2) different planes (Figure 1), (for example, one on the bottom and one on a
vertical side wall, or on two separate vertical side walls). Use multiple suction sources to reduce risk of entrapment. Failure to maintain fittings and covers can lead to severe injury or death. Use of fittings when covers are broken, loose or missing can lead to severe injury or death. If using 1½ in. plumbing. Consult your local building dept. for codes or ordinances that may apply.
V
Remove the pressure test plugs and/or plugs used in winterization of the pool/spa from the suction outlets.
Three (3) feet minimum
Three (3) feet
minimum
Two on Pool Walls
Figure 1: Alternate Location for Suction Outlets
One on Wall / One on Floor
Figure 2: Two Suction Outlets per Pump
If you have any questions about installation or maintenance of this drain cover, please contact your pool professional. Never attempt to alter or repair the cover or frame on your own.
StarGuard® 8-inch Round Main Drain Installation Guide
VI
VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT
The Virginia Graeme Baker Pool and Spa Safety Act raises certain new requirements on owners and
operators of swimming pools and spas. Pools or spas constructed on or after December 19, 2008, shall utilize:
(A) A multiple main drain system without isolation capability with suction outlet covers that meet
ASME/ANSI A112.19.8a Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs and either:
(i) A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 Manufactured Safety Vacuum Release Systems (SVRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub, and Wading Pool Suction Systems and/or ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release Systems (SVRS) for Swimming Pools, Spas and Hot Tubs or
(ii) A properly designed and tested suction-limiting vent system or
(iii) An automatic pump shut-off system.
Pools and spas constructed prior to December 19, 2008, with a single submerged suction outlet shall use a suction outlet cover that meets ASME/ANSI A112.19.8a and either:
(A) A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 and/or ASTM F2387,
or (B) A properly designed and tested suction-limiting vent system, or (C) An automatic pump shut-off system, or (D) Disabled submerged outlets, or (E) Suction outlets shall be reconfigured into return inlets.
For more information about the Virginia Graeme Baker Pool and Spa Safety Act, contact the Consumer Product Safety Commission at (301) 504-7908 or visit www.cpsc.gov.
NOTE: Always turn off all power to the pool pump before installing the cover or working on any suction outlet.
StarGuard® 8-inch Round Main Drain Installation Guide
ACTS CODES AND STANDARDS
Important Acts Codes and Standards Information
StarGuard® and all suction outlet fittings (drain covers) are federally regulated by the U.S. Consumer Product Safety Commission (CPSC). This authority was given to the CPCS in 2007 as part of the Virginia Graeme Baker Pool and Spa Safety Act. Visit www.cpsc.org for more information.
ASME/ANSI A112.19.8a Certification These suction fittings, for use in swimming pools, wading pools, spas and hot tubs, were tested and certified to
the aforementioned safety regulations, by IAPMO Research and Testing. 5001 E. Philadelphia St. Ontario, CA 91761 – USA 877-4UPCMARK (toll free). Product certification commenced April 2009, test results can be obtained from: www.pentairwater.com and/or http://pld.iapmo.org/
NSF/ANSI-50 StarGuard® is certified to comply with NSF/ANSI 50 Circulation system components and related materials
forswimming pools, spas/hot tubs. To download a current copy of the NSF certification, go to http://www.nsf.org/ certified/pools/.
Virginia Graeme Baker Pool and Spa Safety Act StarGuard® is certified to comply with the Virginia Graeme Baker Pool and Spa Safety Act, Section 1404(b).
This section requires all suction outlet fittings (drain covers) to conform to ASME/ANSI A112.19.8a.
International Code Council StarGuard® is an approved component as required by the International Code Council (ICC) building codes,
which include the International Residential Code (IRC), and the International Building Code (IBC), collectively know as the iCodes. The ICC updates the iCodes every three years. For more information, visit www.iccsafe.org.
International Residential Code (IRC) Many states and local jurisdictions have adopted the IRC, including Appendix G. Section AG106 addresses
Suction Entrapment Avoidance requirements that regulate residential swimming pools and spas. It is important to know if these codes are in affect where the residential pool or spa is being built and which version is being required. Effective in the 2009 version of the IRC is the requirement to build in accordance with ANSI/APSP 7 - 2006 American National Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs, and Catch Basins. 2003 and 2006 versions do not include a reference to the ANSI/APSP 7 standard, instead they included the requirement that all pools and spas be equipped with dual-drains and a vacuum relief system that can be either an Approved Gravity Drainage System, or a Safety Vacuum Release System (SVRS) such as the IntelliFlo® VS+ SVRS pump. Visit www.iccsafe.org for more information.
VII
International Building Code (IBC) Many states and local jurisdictions have adopted the International Building Code which regulates commercial
building projects, including public swimming pools and spas. Section 3109.5 addresses Suction Entrapment Avoidance requirements that regulate public swimming pools and spas. It is important to know if these codes are in affect where the public pool or spa is being built and which version is being required. Effective in the 2009 version of the IBC is the requirement to build in accordance with ANSI/APSP 7 - 2006 American National Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs, and Catch Basins. 2003 and 2006 versions do not include a reference to the ANSI/APSP 7 standard, instead they included the requirement that all pools and spas be equipped with dual-drains and a vacuum relief system that can be either an Approved Gravity Drainage System, or a Safety Vacuum Release System (SVRS) such as the IntelliFlo® VS+ SVRS pump. Visit www.iccsafe.org for more information.
ANSI/APSP-7 Suction Entrapment Avoidance Standard The Association of Pool and Spa Professionals publishes many swimming pool and spa related standards,
including ANSI/APSP 7 - 2006 American National Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs, and Catch Basins. ANSI/APSP 7 is referenced by the iCodes, and is required by some states and local jurisdictions. It requires all suction outlet fittings (drain covers) to be tested and Listed by a nationally recognized testing laboratory as conforming to most recent version of ASME/ANSI A112.19.8a. Visit www.apsp.org for more information.
StarGuard® 8-inch Round Main Drain Installation Guide
1
Hydraulic System Specifications
POOL PUMP SUCTION REQUIREMENTS
Pump suction is hazardous and can trap and drown or disembowel bathers. Do not use or allow anyone else to use a pool, spa, or hot tub unless it has at least two (2) suction outlets to each pump suction line (see Figure 1, Outlets Per Pump, below). Do not use or operate swimming pools, spas, or hot tubs if a suction outlet cover is missing, broken, or loose. Follow the guidelines below for a pump installation which minimizes risk to users of pools, spas, and hot tubs.
Entrapment Protection
The pump suction system must provide protection against the hazard of suction entrapment or hair entrapment/ entanglement.
Suction Outlet Covers
All suction outlet covers must be maintained. They must be replaced if cracked, broken, or missing. See page vii for outlet cover certification requirements. All suction outlets must have correctly installed, screw-fastened covers in place.
Outlets Per Pump
Provide at least two (2) hydraulically balanced main drains, with covers (see Figure 1), for each swimming pool pump suction line. The centers of the main drains (suction fittings) must be at least three (3) feet apart.
The system must be built so that it cannot operate with the pump drawing water from only one (1) main drain (that is, there must be at least two (2) main drains connected to the pump whenever it is running, see Figure 1). However, if two (2) main drains run into a single suction line, the single suction line may be equipped with a valve which will shut off both main drains from the pump (see Figure 1).
For existing single drain pools and spas, or multiple main drains located less than three feet (3) apart, a backup system must be installed, such as the IntelliFlo® VS +SVRS. Other backup systems include, approved gravity draining systems, or suction-limiting vent.
At least
three (3) Feet
VGB 2008
certified
Anti-entrapment
Cover or Suction Fitting,
screw-fastened to
Main Drain Sump
Suction Outlet
(Main Drain)
Water Velocity and Flow Rates
The maximum water velocity through drain covers is limited by some local regulations, for example some state health departments limit the velocity through public pool drain covers to 1-1/2 feet per second. This velocity limit is lower than the flow rating provided by the ASME A112.19.8 certification, therefore local limit applies and must be followed. Never exceed the flow rating listed on the cover even if local code does not provide a velocity limit (see Chart 2 on page 2).
No valves between Tee and Main Drain
Valves OK between pump and Te
e
Figure 1: Outlets Per Pump
Cover or Suction Fitting,
s
VGB 2008
certified
Anti-entrapment
screw-fastened to
Main Drain Sump
Suction Outlet
(Main Drain
Pump
)
StarGuard® 8-inch Round Main Drain Installation Guide