Sta-rite

Sta-rite 5MPRA6D-147 User Manual

Loading...

DYNA-GLASTM CENTRIFUGAL PUMPS

WITH INTEGRAL TRAP

O W N E R ’ S M A N U A L

INSTALLATION, OPERATION & PARTS

5MPRA Series MODELS

5MPRA6C-146 5MPRA6C3-146 5MPRA6D-147 5MPRA6D3-147 5MPRA6E-148 5MPRA6E3-148 5MPRA6F-156 5MPRA6F3-156

This manual should be furnished to the end user of this pump; its use will reduce service calls and chance of injury and will lengthen pump life.

STA-RITE FOREIGN SALES CORP.

175 WRIGHT STREET, DELAVAN, WISCONSIN 53115 USA Telephone: (414) 728-5551; Telefax: (414) 728-4461 Cable: STAREX; Telex: (ITT) 4970245

© 1994, Sta-Rite Industries, Inc.

Printed in U.S.A.

S 289 (Rev. 3/17/94)

‘5MPRA’ SERIES PUMP WITH TRAP

To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY!

The Sta-Rite ‘5MPRA’ Series Self-priming Centrifugal pump:

Is designed for use with swimming pools or as a centrifugal pump.

Is an excellent performer; durable, reliable.

 

Table of Contents

Warranty.......................................................................................................

2

Safety Instructions ........................................................................................

3

Installation ....................................................................................................

4

Electrical....................................................................................................

5-6

Operation .....................................................................................................

7

Storage/Winterizing ...................................................................................

7-8

Pump Service...........................................................................................

9-10

Troubleshooting Guide ...............................................................................

11

Repair Parts List ..........................................................................................

12

LIMITED WARRANTY

Pumps, filters, spa systems, skimmers, underwater lights (except bulbs), accessories and fittings manufactured by Sta-Rite are warranted to be free of defects in material and workmanship for one (1) year from date of installation.

HRPB, DEPB and System 3 are warranted against defects in material and workmanship for a period of ten (10) years from date of installation. Internal filter components and valves are warranted for a period of one (1) year from date of installation.

The foregoing warranties relate to the original consumer purchaser (“Purchaser”) only. Sta-Rite shall have the option to repair or replace the defective product, at its sole discretion. Purchasers must pay all labor and shipping charges necessary to replace the product covered by this warranty. Requests for warranty service must be made through the installing dealer. This warranty shall not apply to any product that has been subject to negligence, misapplication, improper installation or maintenance, or other circumstances which are not in Sta-Rite’s direct control.

This warranty sets forth Sta-Rite’s sole obligation and Purchaser’s exclusive remedy for defective products.

STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Supersedes all previous publications.

Sta-Rite Industries, Inc., 600 S. Jefferson St., Waterford, WI 53185

2

IMPORTANT SAFETY INSTRUCTIONS

Always follow basic safety precautions with this equipment, including the following.

To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.

This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity.

SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL

INSTRUCTIONS!

This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert

to the potential for personal injury.

warns about hazards that will cause death, serious personal injury, or major property damage if ignored.

warns about hazards that can cause death, serious personal injury, or major property damage if ignored.

warns about hazards that will or can cause minor personal injury or property damage if ignored.

NOTICE indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on equipment. Keep safety labels in good condition; replace if missing or damaged.

Incorrectly installed or tested equipment may fail, causing

severe injury or property damage.

Read and follow instructions in owner's manual when installing and operating equipment. Have a trained pool professional per-

form all pressure tests.

1.Do not connect system to a high pressure or city water system.

2.Use equipment only in a pool or spa installation.

3.Trapped air in system can cause explosion. BE SURE all air is out of system before operating or testing equipment.

Before pressure testing, make the following safety checks:

Check all clamps, bolts, lids, and system accessories before testing.

Release all air in system before testing.

Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-m) torque for testing.

Water pressure for test must be less than 25 PSI (7.5 kg/cm2).

Water Temperature for test must be less than 100o F. (38o C).

Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. Remove trap lid and retighten hand tight only.

NOTICE: These parameters apply to Sta-Rite equipment only. For non-Sta-Rite equipment, consult manufacturer.

3

NOTICE: Port threads are: Internal - 2" NPT for direct connection to pipe. External - 3-1/4" Buttress. Fits Sta-Rite U11-200P Union Half for quick disconnect pipe connection.

STRAINER BASKET

DISCHARGE PORT COVER

TO FILTER OR POOL

SUCTION

PORT

FROM

POOL

OR

VACUUM

FILTERS

 

PUMP MAY BE BOLTED TO LEVEL

Figure 1

FOUNDATION OR MOUNTING BRACKET

INSTALLATION

Only qualified, licensed personnel should install pump and wiring.

Pump mount must:

Be solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.)

Allow pump suction inlet height to be as close to water level as possible. Pump will not lift water more than 10'(3m).

Allow use of short, direct suction pipe (To reduce friction losses). Allow for gate valves in suction and discharge piping.

Have adequate floor drainage to prevent flooding. Be protected from excess moisture.

Allow adequate access for servicing pump and piping.

NOTICE: When connecting threaded pipe directly to pump, use Teflon tape or Plasto-Joint Stik1 to seal connections. Do not use pipe dope; pipe dope causes cracking in some plastics and may damage components in piping system.

When connecting pipe to pump with union half, use Teflon tape or PlastoJoint Stik between pipe and union adapter. Union collar to pump should be assembled dry and hand-tight.

NOTICE: Pump suction and discharge connections have molded in thread stops. DO NOT try to screw pipe in beyond these stops.

Teflon Taping Instructions:

Use only new or clean PVC pipe fittings.

Wrap male pipe threads with one to two layers of Teflon tape. Cover entire threaded portion of pipe.

Do not overtighten or tighten past thread stop in pump port!

If leaks occur, remove pipe, clean off old tape, rewrap with one to two additional layers of tape and remake the connection.

NOTICE: Support all piping connected with pump!

1Lake Chemical Co., Chicago, Illinois

4