SSAC TSD6 Digi-Timer Catalog Page

Interval Interval
Interval
Interval Interval
(Single Pulse On Operate)(Single Pulse On Operate)
(Single Pulse On Operate)
(Single Pulse On Operate)(Single Pulse On Operate) TSD6 Digi-Timer Timing Module
DescriptionDescription
Description
DescriptionDescription
The TSD6 offers total solid state interval timing for 12 or 24 V DC applications. This series provides either negative or positive switching. The TSD Series is designed for more demanding commercial and industrial applications where small size, and accurate performance is required. The factory calibration for fixed time delays is within 1% of the target time delay. The repeat accuracy, under stable conditions, is 0.1% of the time delay. The TSD Series is rated to operate over an extended temperature range. Time delays of 0.1 seconds to 100 hours are available. The output is rated 1 A steady and 10 A inrush. The modules are totally solid state and encapsulated to protect the electronic circuitry.
Fixed or Adjustable Delays From 0.1 s... 100 h +/-0.1% Repeat Accuracy +/-1% Factory Calibration 12 or 24 V DC Interval Timing 1 A Solid State Output Encapsulated
Approvals:
AccessoriesAccessories
Accessories
AccessoriesAccessories
BB
B
BB
External adjust potentiometer P/Ns:
AA
A
AA
P1004-95P1004-95
P1004-95
P1004-95P1004-95 P1004-95-X P1004-95-X
P1004-95-X (fig B)
P1004-95-X P1004-95-X
Mounting bracket
P1023-6 P1023-6
P/N:
P1023-6
P1023-6 P1023-6
Female quick connect
::
P/N
:
::
P1015-64P1015-64
P1015-64
P1015-64P1015-64
Quick connect to screw adaptor
P1015-18 P1015-18
P/N:
P1015-18
P1015-18 P1015-18
(fig A)
(AWG 14/16)
OperationOperation
Operation
OperationOperation
Upon application of input voltage, the time delay begins. The output energizes during the time delay. At the end of the time delay, the output de-energizes and remains de-energized until input voltage is removed.
Reset:Reset:
Reset: Removing input voltage resets the time delay
Reset:Reset:
and the output.
ConnectionConnection
Connection
ConnectionConnection
+-
Positive Switching
RT is used when external adjustment is ordered. Dashed lines are internal connections.
FunctionFunction
Function
FunctionFunction
Interval
V = Voltage L = Load R = Reset TD = Time Delay
Negative Switching
= Undefined time
+-
Versa-knob
P0700-7 P0700-7
P/N:
P0700-7
P0700-7 P0700-7
DIN rail P/Ns: 017322005 017322005
017322005 (Steel)
017322005 017322005 C103PM C103PM
C103PM (Al)
C103PM C103PM
DIN rail adaptor
P1023-20 P1023-20
P/N:
P1023-20
P1023-20 P1023-20
See accessory pages for specifications.
OrOr
dering Tdering T
Or
dering T
OrOr
dering Tdering T
TSD6TSD6
TSD6
TSD6TSD6
SeriesSeries
Series
SeriesSeries
Example P/N: Example P/N:
Example P/N:
Example P/N: Example P/N:
ableable
able
ableable
XX
X
XX
InputInput
Input
InputInput
11
1 - 12 V DC
11 33
3 - 24 V DC
33
TSD6320PTSD6320P
TSD6320P
TSD6320PTSD6320P
Fixed –
XX
X
XX
AdjustmentAdjustment
Adjustment
AdjustmentAdjustment
11
1 - Fixed
11 22
2
- External
22
Adjust
33
- -
3
- Onboard
33
- -
Adjust
TSD6110.1SNTSD6110.1SN
TSD6110.1SN
TSD6110.1SNTSD6110.1SN
XX
X
XX
Time DelayTime Delay
Time Delay *
Time DelayTime Delay
00
0 - 0.1 ... 10 s
00 11
1 - 1 ... 100 s
11 22
2 - 10 ... 1000 s
22 33
3 - 0.1 ... 10 m
33 44
4
- 1 ... 100 m
44 55
5 - 10 ... 1000 m
55 66
6 - 1 ... 100 h
66
XX
X
XX
Switching ModeSwitching Mode
Switching Mode
Switching ModeSwitching Mode
PP
P - Positive
PP NN
N - Negative
NN
*If Fixed Delay is selected, insert delay [ followed by ( min., or [
0.10.1
0.1...
0.10.1 SS
S) sec. or (
SS
11
100100
1 ...
100] (
11
100100
10001000
1000]
10001000
HH
H) hours.
HH
Low Voltage Products & Systems5.148
MM
))
M
)
MM
))
TSD6Gen 07.02.04
Interval Interval
Interval
Interval Interval
(Single Pulse On Operate)(Single Pulse On Operate)
(Single Pulse On Operate)
(Single Pulse On Operate)(Single Pulse On Operate) TSD6 Digi-Timer Timing Module
Technical DataTechnical Data
Technical Data
Technical DataTechnical Data
Time DelayTime Delay
Time Delay
Time DelayTime Delay
Range 0.1 s ... 100 h 7 adjustable ranges or fixed Repeat Accuracy +/-0.1% or 20 ms, whichever is greater Tolerance (Factory Calibration) ≤ +/-1% Reset Time 150 ms Time Delay vs. Temperature & Voltage ≤ +/-1%
InputInput
Input
InputInput
Voltage 12 or 24 V DC Tolerance +/-15% Ripple +/-10% Power Consumption 1 W
OutputOutput
Output
OutputOutput
Type Solid state, positive or negative switching Form Normally Open, closed during timing Maximum Load Current 1 A steady state, 10 A inrush at 60°C Off State Leakage Current 1 mA Voltage Drop 1.0 V at 1 A
ProtectionProtection
Protection
ProtectionProtection
Circuitry Encapsulated Dielectric Breakdown 2000 V RMS terminals to mounting surface Insulation Resistance 100 M Polarity Units are reverse polarity protected
MechanicalMechanical
Mechanical
MechanicalMechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) Termination 0.25 in. (6.35 mm) male quick connect terminals
EnvironmentalEnvironmental
Environmental
EnvironmentalEnvironmental
Operating Temperature -40°C ... +75°C Storage Temperature -40°C ... +85°C Humidity 95% relative, non-condensing Weight 2.4 oz (68 g)
External Resistance vs Time DelayExternal Resistance vs Time Delay
External Resistance vs Time Delay
External Resistance vs Time DelayExternal Resistance vs Time Delay
TSD6Gen 07.02.04
Mechanical ViewMechanical View
Mechanical View
Mechanical ViewMechanical View
Fixed & External AdjustFixed & External Adjust
Fixed & External Adjust
Fixed & External AdjustFixed & External Adjust
Onboard AdjustOnboard Adjust
Onboard Adjust
Onboard AdjustOnboard Adjust
Inches (Millimeters)
Low Voltage Products & Systems 5.149
Loading...