Recycling (Flasher)Recycling (Flasher)
Recycling (Flasher)
Recycling (Flasher)Recycling (Flasher)
TSD3 Digi-Timer
Timing Module
DescriptionDescription
Description
DescriptionDescription
The TSD3 is a solid state ON/OFF recycling timer with the ON time always equal to the OFF time. When time
delay is changed by the R
more demanding commercial and industrial applications where small size, and accurate performance is required.
The factory calibration for fixed time delays is within 1% of the target time delay. The repeat accuracy, under
stable conditions, is 0.1% of the time delay. The TSD Series is rated to operate over an extended temperature
range. Time delays of 0.1 seconds to 100 hours are available. The output is rated 1 A steady and 10 A inrush.
The modules are totally solid state and encapsulated to protect the electronic circuitry.
both the ON and the OFF periods are changed. The TSD Series is designed for
T,
Fixed or Adjustable Delays
From 0.1 s... 100 h
Equal ON and OFF Delays
+/-0.1% Repeat Accuracy
+/-1% Factory Calibration
24, 120, or 230 V AC
1A Solid State Output
Encapsulated
Approvals:
AccessoriesAccessories
Accessories
AccessoriesAccessories
BB
B
BB
External adjust
potentiometer
P/Ns:
AA
A
AA
P1004-95 P1004-95
P1004-95 (fig A)
P1004-95 P1004-95
P1004-95-X P1004-95-X
P1004-95-X (fig B)
P1004-95-X P1004-95-X
Mounting bracket
P/N:
Female quick
connect
P/N
P1015-64P1015-64
P1015-64
P1015-64P1015-64
Quick connect to
screw adaptor
P/N:
P1023-6 P1023-6
P1023-6
P1023-6 P1023-6
::
:
::
P1015-18 P1015-18
P1015-18
P1015-18 P1015-18
(AWG 14/16)
OperationOperation
Operation
OperationOperation
Upon application of input voltage, the output energizes
and the T1, ON time begins. At the end of the ON time,
the output de-energizes and the T2, OFF time begins.
At the end of the OFF time, the output energizes and
the cycle repeats as long as input voltage is applied.
Reset:Reset:
Reset: Removing input voltage resets the output and
Reset:Reset:
time delays, and returns the sequence to the T1, ON
time.
ConnectionConnection
Connection
ConnectionConnection
RT is used when external adjustment is ordered.
Dashed lines are internal connections.
FunctionFunction
Function
FunctionFunction
Recycling (ON First)
V = Voltage R = Reset L = Load
T1 = ON Time T2 = OFF Time
T1 ≅ T2
Versa-knob
P0700-7 P0700-7
P/N:
P0700-7
P0700-7 P0700-7
DIN rail P/Ns:
017322005 017322005
017322005 (Stee l)
017322005 017322005
C103PM C103PM
C103PM (Al)
C103PM C103PM
→
DIN rail adaptor
P1023-20 P1023-20
P/N:
P1023-20
P1023-20 P1023-20
See accessory pages for
specifications.
←
OrOr
dering Tdering T
Or
dering T
OrOr
dering Tdering T
TSD3TSD3
TSD3
TSD3TSD3
SeriesSeries
Series
SeriesSeries
Example P/N: Example P/N:
Example P/N:
Example P/N: Example P/N:
ableable
able
ableable
XX
X
XX
InputInput
Input
InputInput
22
–
2 - 24 V AC
22
44
–
4 - 120 V AC
44
66
–
6 - 230 V AC
66
TSD3421TSD3421
TSD3421
TSD3421TSD3421
XX
X
XX
AdjustmentAdjustment
Adjustment
AdjustmentAdjustment
11
–
1 - Fixed
11
22
–
2
- External
22
Adjust
33
–
3
33
Adjust
Fixed –
--
- Onboard
--
TSD3410.5STSD3410.5S
TSD3410.5S
TSD3410.5STSD3410.5S
XX
X
XX
Time DelayTime Delay
Time Delay *
Time DelayTime Delay
00
–
0 - 0.1 ... 10 s
00
11
–
1 - 1 ... 100 s
11
22
–
2 - 10 ... 1000 s
22
33
–
3 - 0.1 ... 10 m
33
44
–
4
- 1 ... 100 m
44
55
–
5 - 10 ... 1000 m
55
66
–
6 - 1 ... 100 h
66
*If Fixed Delay is selected,
0.10.1
insert delay [
followed by (
0.10.1
or [
0. 1 ...
0.10.1
0.1...
0.10.1
SS
S) sec. or (
SS
100100
HH
100] (
H) hours.
100100
HH
10001000
1000]
10001000
Low Voltage Products & Systems5.188
MM
M) min.,
MM
TSD3Gen 07.01.04

Recycling (Flasher)Recycling (Flasher)
Recycling (Flasher)
Recycling (Flasher)Recycling (Flasher)
TSD3 Digi-Timer
Timing Module
Technical DataTechnical Data
Technical Data
Technical DataTechnical Data
Time DelayTime Delay
Time Delay
Time DelayTime Delay
Range 0.1 s ... 100 h in 7 adjustable ranges or fixed
Repeat Accuracy +/-0.1% or 20 ms, whichever is greater
Tolerance (Factory Calibration) ≤ +/-1%
Reset Time ≤ 150 ms
Time Delay vs. Temperature & Voltage ≤ +/-1%
InputInput
Input
InputInput
Voltage 24, 120, or 230 V AC
Tolerance +/-20%
Line Frequency 50 ... 60 Hz
Power Consumption ≤ 2 VA
OutputOutput
Output
OutputOutput
Type Solid state
Maximum Load Current 1 A steady state, 10 A inrush at 60°C
Off State Leakage Current ≅ 5 mA at 230 V AC
Voltage Drop ≅ 2.5 V at 1 A
ProtectionProtection
Protection
ProtectionProtection
Circuitry Encapsulated
Dielectric Breakdown ≥ 2000 V RMS terminals to mounting surface
Insulation Resistance ≥ 100 MΩ
MechanicalMechanical
Mechanical
MechanicalMechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw
Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Termination 0.25 in. (6.35 mm) male quick connect terminals
EnvironmentalEnvironmental
Environmental
EnvironmentalEnvironmental
Operating Temperature -40°C ... +75°C
Storage Temperature -40°C ... +85°C
Humidity 95% relative, non-condensing
Weight ≅ 2.4 oz (68 g)
External Resistance vs Time DelayExternal Resistance vs Time Delay
External Resistance vs Time Delay
External Resistance vs Time DelayExternal Resistance vs Time Delay
TSD3Gen 07.01.04
Mechanical ViewMechanical View
Mechanical View
Mechanical ViewMechanical View
Fixed & External AdjustFixed & External Adjust
Fixed & External Adjust
Fixed & External AdjustFixed & External Adjust
Onboard AdjustOnboard Adjust
Onboard Adjust
Onboard AdjustOnboard Adjust
Inches (Millimeters)
Low Voltage Products & Systems 5.189