Splendide C6200CEE, WDC6200CEE-LD Datasheet

Data Sheet Includes Information On
Splendide
Product Model Number
WDC6200CEE - (LD)
Comb-o-matic 6200 Laundry Center
Installation Location:
· Unit may be installed in recessed area, closet, or alcove.
· Floor must support at least 280 lbs. and be a solid, level surface.
· When locating in a towable trailer or watercraft, position the machine over the axles or mid-ship where movement is at a minimum. Block unit in to prevent extreme movement.
Electrical Requirements:
· Machine Voltage/Amperage: 120V, 13 Amp, 60 Hz.
· Connection: 3-prong plug with 6' cord is provided with unit.
· Circuit/Protector: 3-wire single phase, 120V, 60Hz, AC, on separate 15 Amp circuit.
Standpipe Drain System/ Sink Draining Requirements:
· Needs a 1 ¼" (3.2 cm) minimum diameter standpipe with the minimum carry-away capacity of 7 gallons (26 liters) per minute. Top of standpipe must be at least 25" (62 cm) high and no higher than 34" (86 cm) from the bottom of the washer.
· Outlet end of drain hose (provided with the unit) must be at least 20" above bottom of washer. An air break must be available at the standpipe to avoid siphoning.
· Faucet Adapter Kit #154187104A is available to allow for direct faucet connection. See complete installation instruction on drain hose draining directly into sink, connection to dishwasher Wye fitting, and disposer/drain connection in owners manual.
· Optional Drain-A-Way™ Pans are available. Pan #PI-24 for cabinet or under­ counter installations. Pan #P-24 for free- standing installations. Both are designed to be drain plumbed.
Front View (not to scale)
NOTE: Electrical Cord Location, Drain Outlet, and Water Inlets are located on the rear of the unit
23-7/16"
4-3/4"
2-1/4"
Water Inlets
Control Panel
HC
29-1/2"
Drain Outlet
2-1/2"
Front Leveling
Legs
Side View (not to scale)
NOTE: 24" minimum width entry doors and hallways recommended for ease of installation.
22-7/8" total depth including top overhang and door handle
Plastic U-Clamp
Electrical Cord Location
6' cord length
1-3/8"
29-3/4"
2-1/2"
6"
33-1/8" to 33-1/2"
depending on positioning of leveling legs
NO DRYER VENT REQUIREMENTS ON THIS MACHINE:
· This machine incorporates an internal condenser for drying. All humidity stays within the unit and is drained as water. No heated or air conditioned air is exhausted outside, so no vent is needed. This not only conserves energy, but also avoids problems with the delicate air balance requirements in large multifamily complexes.