Splendide 802M, WD802M Datasheet

Page 1
NOTE: Electrical Cord Location, Drain Outlet, Exhaust Outlet
and Wat er I nl et s ar e lo ca te d on t he r ea r of t he u ni t
Front Leveling
Drain Outlet
Water Inlets
Control Panel
Electrical Cord Location
(depending on positioning of leveling legs)
Side View (not to scale)
Front View (not to scale)
23 ½"
5 ½"
2 ½"
29 ½"
33 ¼" to 33 ¾"
2"
2"
1 ¼"
5 ½"
1 ¼"
36 ¼"
8
Plas tic
U-Clamp
Flexible Drain Hose
(5' length)
Data Sheet Includes Information On
Splendide
Product Model Number
WD802M
Splendide 2000 Laundry Center
Installation Location:
· Unit may be installed in recessed area, closet, or alcove.
· Air Space Requirements: 0" on sides and
1" in front and back (Additional installation spacing needs to be considered for easy installation, servicing, and compliance with state and federal codes.)
· Floor must support at least 280 lbs. and be a solid, level surface.
· When locating in a towable trailer or watercraft, position the machine over the axles or mid-ship where movement is at a minimum. Block unit in to prevent extreme movement.
Electrical Requirements:
· Machine Voltage/Amperage: 115 V, 60 H z,
12.5 Amps
· Connection: 3-prong plug with 6' cord is provided with unit.
· Circuit/Protector: 3-wire single phase, 120V, 60Hz, AC, on separate 15-ampere circuit.
Standpipe Drain System/ Sink Draining Requirements:
· Needs a 1 ¼" (3.2 cm) minimum diameter
standpipe with the minimum carry-away capacity of 7 gallons (26 liters) per minute. Top of standpipe must be at least 25" (62 cm) high and no higher than 34" (86 cm) from the bottom of the washer.
· Outlet end of drain hose (provided with the unit) must be at least 20" above bottom of washer. An air break must be available at the standpipe to avoid siphoning.
· Faucet Adapter Kit #154187104A is available to allow for direct faucet connection. See complete installation instruction on drain hose draining directly into sink, connection to dishwasher Wye fitting, and disposer/drain connection in owners manual.
· Optional Drain-A-Way Pans are available. Pan #PI-22 for cabinet or under- counter installations. Pan #P-24 for freestanding installations. Both designed to be drain plumbed.
Exhaust Requirements:
· DO NOT exhaust dryer into a chimney,
furnace, cold air duct, attic, crawl space, or another duct used for venting
· If cabinet door is installed, a minimum of 8 sq. inches should be provided. Louvered doors with equivalent air openings are acceptable. Allow clearance behind the door(s) to avoid rubbing between back of cabinet door(s) and front of unit control panel. Additional clearances for wall, door and floor moldings may be required.
· Rigid or flexible metallic duct required. Ducting must slope downwards and away from the machine.
installation instructions are available upon request and in the owner's manual that comes with the unit.
H
C
8"
Ex haust Outlet
(4" diam.)
31 ¼"
3
8
26 ¾ "
1"
4"
20 ½ "
21 "