NOTE: Electrical Cord Location, Drain Outlet, Exhaust Outlet
and Wat er I nl et s ar e lo ca te d on t he r ea r of t he u ni t
Front Leveling
Drain Outlet
Water Inlets
Control Panel
Electrical Cord Location
(6' cord length)
(depending
on positioning
of leveling
legs)
Side View (not to scale)
Front View (not to scale)
23 ½"
5 ½"
2 ½"
29 ½"
33 ¼" to 33 ¾"
2"
2"
1 ¼"
5 ½"
1 ¼"
36 ¼"
8
Plas tic
U-Clamp
Flexible
Drain Hose
(5' length)
Data Sheet Includes Information On
Splendide
Product Model Number
WD802M
Splendide 2000 Laundry Center
Installation Location:
· Unit may be installed in recessed area,
closet, or alcove.
· Air Space Requirements: 0" on sides and
1" in front and back (Additional installation
spacing needs to be considered for easy
installation, servicing, and compliance with
state and federal codes.)
· Floor must support at least 280 lbs. and be
a solid, level surface.
· When locating in a towable trailer or
watercraft, position the machine over
the axles or mid-ship where movement is
at a minimum. Block unit in to prevent
extreme movement.
Electrical Requirements:
· Machine Voltage/Amperage: 115 V, 60 H z,
12.5 Amps
· Connection: 3-prong plug with 6' cord is
provided with unit.
· Circuit/Protector: 3-wire single phase, 120V,
60Hz, AC, on separate 15-ampere circuit.
Standpipe Drain System/ Sink Draining
Requirements:
· Needs a 1 ¼" (3.2 cm) minimum diameter
standpipe with the minimum carry-away
capacity of 7 gallons (26 liters) per minute.
Top of standpipe must be at least 25" (62
cm) high and no higher than 34" (86 cm)
from the bottom of the washer.
· Outlet end of drain hose (provided with the
unit) must be at least 20" above bottom of
washer. An air break must be available at
the standpipe to avoid siphoning.
· Faucet Adapter Kit #154187104A is
available to allow for direct faucet
connection. See complete installation
instruction on drain hose draining directly
into sink, connection to dishwasher Wye
fitting, and disposer/drain connection in
owners manual.
· Optional Drain-A-Way™ Pans are
available. Pan #PI-22 for cabinet or under-
counter installations. Pan #P-24 for
freestanding installations. Both designed to
be drain plumbed.
Exhaust Requirements:
· DO NOT exhaust dryer into a chimney,
furnace, cold air duct, attic, crawl space, or
another duct used for venting
· If cabinet door is installed, a minimum of 8
sq. inches should be provided. Louvered
doors with equivalent air openings are
acceptable. Allow clearance behind the
door(s) to avoid rubbing between back of
cabinet door(s) and front of unit control
panel. Additional clearances for wall, door
and floor moldings may be required.
· Rigid or flexible metallic duct required.
Ducting must slope downwards and away
from the machine.
installation instructions are available upon request and in the owner's manual that comes with the unit.
H
C
8"
Ex haust
Outlet
(4" diam.)
31 ¼"
3
8
26 ¾ "
1"
4"
20 ½ "
21 "