Splendide 2100, WD2100 Datasheet

Data Sheet Includes Information On
Splendide
Product Model Number
WD2100 - (LD)
Splendide 2100 Laundry Center
Installation Location:
· Unit may be installed in recessed area, closet, or alcove.
· Air Space Requirements: 0" on sides and 1" in front and back (from the case). Addi­ tional installation spacing needs to be considered for easy installation, servicing, and compliance with state and federal codes.
· Floor must support at least 280 lbs. and be a solid, level surface.
· When locating in a towable trailer or watercraft, position the machine over the axles or midship where movement is at a minimum. Block unit in to prevent extreme movement.
Electrical Requirements:
· Machine Voltage/Amperage: 115V, 13 Amp, 60Hz
· Connection: 3-prong plug with 6' cord is provided with unit.
· Circuit/Protector: 3-wire single phase, 120V, 60Hz, AC, on separate 15-ampere circuit.
Standpipe Drain System/ Sink Draining Requirements:
· Needs a 1 ¼" (3.2 cm) minimum diameter standpipe with the minimum carry-away capacity of 7 gallons (26 liters) per minute. Top of standpipe must be at least 25" (62 cm) high and no higher than 34" (86 cm) from the bottom of the washer.
· Outlet end of drain hose (provided with the unit) must be at least 20" above bottom of washer. An air break must be available at the standpipe to avoid siphoning.
· Faucet Adapter Kit #154187104A is available to allow for direct faucet connection. See complete installation instruction on drain hose draining directly into sink, connection to dishwasher Wye fitting, and disposer/drain connection in owners manual.
· Optional Drain-A-Way™ Pans are
available. Pan #PI-24 for cabinet or under­ counter installations. Pan #P-24 for free- standing installations. Both are designed to be drain plumbed.
Front View (not to scale)
NOTE: Electrical Cord Location, Drain Outlet, Exhaust Outlet and Water Inlets are located on the rear of the unit
23-7/16"
4-3/4"
2-1/4"
Water Inlets
Control Panel
HC
6"
29-1/2"
Exhaust Outlet
4" diam.
25"
2-1/2"
Side View (not to scale)
NOTE: 24" minimum width entry doors and hallways recommended for ease of installation.
Vent Adapter
23-3/8" total depth including vent adapter and door handle
Drain Outlet
Front Leveling
Legs
Electrical Cord Location
6' cord length
1-3/8"
29-3/4"
2-1/2"
33-1/8" to 33-1/2"
depending on positioning of leveling legs
6"
4"
Plastic U-Clamp
Exhaust Requirements:
· DO NOT exhaust dryer into a chimney,
furnace, cold air duct, attic, crawl space, or another duct used for venting
· If cabinet door is installed, a minimum of 8
sq. inches should be provided. Louvered doors with equivalent air openings are acceptable. Allow clearance behind the door(s) to avoid rubbing between back of cabinet door(s) and front of unit control panel. Additional clearances for wall, door and floor moldings may be required.
· Rigid or flexible metallic duct required.
Ducting must slope downwards and away from the machine.
Never reuse data sheets. Data sheets are subject to change without notice. Never use data sheets for final installation criteria. Complete installation
instructions are available upon request and in the owner's manual that comes with the unit.
Flexible Drain Hose
(5' length)
11/16"
1-1/2"
21-1/16"
22-3/16" total case depth*
34-11/16"