JOI-PNI-242
SPICER
PRODUCT INFORMATION: COATED
BEARING CAPS
PART NUMBER INFORMATION
DATE: October 30, 2013
TO: All Dana Aftermarket Group Customers
Of all the many important details that must be addressed when properly servicing a driveshaft,
overlooking one small detail can cause big problems: Corrosion caused by electrolysis.
Electrolysis will occur when two dis-similar metals are used in close proximity and moisture is
present. Using a u-joint kit with steel bearing caps in a driveshaft assembly with aluminum
yokes will result in electrolysis. When the time comes to service or repair the driveshaft, the ujoint and yoke will have “welded” together making replacement impossible.
To prevent this from occurring, use Spicer
coating to prevent electrolysis.
The most popular light-duty driveshaft series are covered:
Drivesh aft Series
1310 / SPL22 5-3613X
1330 / SPL25 5-3614X
1350 / SPL30 5-3615X
1410 / SPL36 5-3616X
®
SPL® u-joint assemblies with a zinc-phosphate
®
SPL
Premium U -Joint w ith
Coated Bearing Caps
Thank you for your continued support of Spicer
Chris Boesel
Product Manager
Dana Aftermarket Group
®
driveshaft products.