The contents of this manual may
not be reproduced or transmitted
in any form or by any means
electronic, mechanical, or other
means that do not yet exist or
may be developed, including
photocopying, recording, or any
information storage and retrieval
system without the express
permission from Sper Scientic.
Sper Scientic
7720 E. Redeld Rd. Suite #7,
Scottsdale, AZ 85260
Tel: (480) 948-4448
Fax: (480) 967-8736
Web: www.sperscientic.com
23
Page 3
TABLE OF CONTENTS
1. INTRODUCTION . . . . . 4
2. MATERIALS SUPPLIED. . 4
3. FEATURES . . . . . . . . 5
4. FRONT PANEL
DESCRIPTION . . . . . . 6
5. OPERATING
INSTRUCTIONS. . . . . . 7
Power on/off . . . . . . . .7
LCD backlight on/off . . . . 7
Mode selection . . . . . . 7
Unit selection . . . . . . . 9
Special attention for the
Humidity measurement . 10
Air ow measurement . . 11
Hold Function . . . . . . 12
REC (Record) function . 12
Auto power off disable . . 13
6. BATTERY
REPLACEMENT. . . . . 14
7. SPECIFICATIONS. . . . 15
8. WARRANTY. . . . . . . 20
3
Page 4
INTRODUCTION
For environmental testing
anywhere. Model 850026
combines 7 environmental test
functions into a single compact
unit. Features include touchtone buttons, min/max and hold
functions. Comes ready to use
with wrist strap, instructions,
battery and soft carrying case.
MATERIALS SUPPLIED
Meter
Wristlet
CR 2032 DC 3V Battery
Soft Carrying Case
45
Page 5
FEATURES
• 7 professional environmental
instruments in 1
• Lightweight, ergonomic design
• Wristlet design provides extra
protection to the instrument
• Low-friction ball bearing
mounted impeller design
provides high accuracy at
high and low air velocity
2. Power off: Press for > 3
seconds to turn meter off.
LCD backlight on/off
With the meter on, press
once. The LCD backlight will
light for 5 seconds, then shut
off automatically.
Mode selection
This meter offers 7
selectable modes:
a. Anemometer (Air velocity) /
Temp
b. Air ow (CMM, CFM)
c. Wind Chill
d. Humidity/Temp
e. Dew point Temp
f. Wet bulb Temp
g. Heat index
7
Page 8
With the meter on, press HOLD
continuously and the Display
will show the following texts
in sequence:
Display Mode text
An = Anemometer (Air velocity)
/Temp
AirFL = Air ow (CMM, CFM)
CHiLL = Wind chill
rH = Humidity/Temp
dP = Dew point Temp
_Et = Wet bulb Temp
HEAt = Heat index
When the display shows the
desired mode, release HOLD
and the meter will set this mode
as the default.
89
Page 9
Anemometer (Air Velocity)/
Temp Measurement
Unit Selection
REC button = Enter button
1. With the power on, press
REC for >3 seconds, the
display will show Unit.
Release REC, then press
to scroll through the available
scales. After the desired scale
is selected, press REC to
save as the default.
2. The next screen displays
“dCdF” with the current
temperature scale selection
(°C or °F) below. Press to
select the desired scale. Press
REC to save as the default.
Note…
When CHiLL, rH, dP, _Et and
HEAt are the selected mode,
you may only change the
temperature scale setting.
(°C or °F)
9
Page 10
The selection scales
for all modes are:
MeasurementScales
m/s, Km/h,
Air Velocity
Temp. (Air velocity) °C/°F
Air owCMM, CFM
Wind chill°C/°F
Temp. (Humidity)°C/°F
Dew point°C/°F
Wet bulb Temp.°C/°F
Heat index°C/°F
mph, knot,
FPM
Note…
For the most accurate
reading for the humidity/
Temp., Dew point Temp.,
Wet bulb Temp., Heat index
measurement, do not touch
or block the humidity sensor
at any time with your hand.
1011
Page 11
Air ow measurement
1. With the Power on, select Air
ow mode (refer to page 7)
2. Set the measurement area
dimension: Press Hold once,
the display will show HOLD
then press REC continuously
until the lower left of the
Display shows m-2 or F-2
m-2 = meter square
F-2 = ft square
The unit of measure is
determined by the selected
scale CMM or CFM
3. Use Hold and to adjust
the air ow dimension value.
When the desired dimension
value is set, press REC to
save as the default.
button = ▲button
Hold button = ▼ button
REC button = Enter button
Page 12
Hold Function
Pressing Hold will freeze the
current reading on the display.
The HOLD symbol will be
displayed at the top of the
display window.
To release the Hold function,
press Hold again, the HOLD
indicator will disappear and
the current reading will be
displayed.
REC (Record) function
The REC (Record) function
will record and display the
maximum and minimum
readings.
1. Start the Record function
by pressing REC once.
The REC symbol will appear
on the display.
2. With the REC symbol on
the display:
1213
Page 13
a. Press REC once and the
Max symbol will appear on
the display along with the
current maximum value.
b. Press REC again, the MIN
symbol will appear on
the display along with the
current minimum value.
c. Clear the recorded MAX or
MIN value from the display
by pressing Hold once.
The MAX/MIN symbols
and their readings, will
disappear from the display.
The meter will return to the
REC function and continue
recording.
d. To exit REC function press
REC button for >2 seconds.
Auto power off disable
In order to prolong the battery
life, this instrument has an Auto
Power Off function: the meter
will turn off if no buttons are
13
Page 14
pressed for approximately
10 minutes.
To disable the Auto Power Off
function, press REC and enter the
record function (page 12). The Auto
power off function will be disabled
until the record function is exited.
REPLACE BATTERY
1. When the LCD display
shows symbol, it is
time to replace the battery.
(Measurements may still
be made for several hours
after the low battery indicator
appears.)
2. Open the Battery Compartment
and remove the battery.
3. Install the battery (CR2032)
and replace the cover.
1415
Page 15
GENERAL SPECIFICATIONS
Display8 mm LCD display
Measurement 1. Anemometer
(Air velocity)/Temp
2. Humidity/Temp
3. CMM, CFM
4. Dew point
5. Wet bulb
6. Wind chill
7. Heat index
Operating
Humidity
Operating
Temperature
Over Input
Display
Power Supply CR 2032 DC
Power
Consumption
Weight160g (battery
Dim (HWD)4.7" x 1.8" x 1.2"
Standard
Accessories
Max. 80% RH
0 ~ 50°C
(32 ~ 122°F)
“- - - -”
3V battery
Approx. DC 5 mA
included)
(120 x 45 x 20 mm)
Instruction Manual,
battery, soft case
15
Page 16
ELECTRICAL SPECIFICATIONS
(±23 ±5°C)
Air Velocity
UnitRangeRes.Acc.
ft/min80 ~ 39271
m/s0.4 ~ 20.00.1
km/h1.4 ~ 72.00.1
mph0.9 ~ 44.70.1
knots0.8 ~ 38.80.1
Temp.
°C/°F
ft/min: feet per minute
m/s: meters per second
km/h: kilometers per hour
mph: miles per hour
knots: nautical miles per hour
0 ~ 50°C0.1°C ± 1.2°C
32 ~ 122°F0.1°F± 2.5°F
≤20 m/s:
±3% F.S.
>20 m/s:
±4% F.S.
1617
Page 17
ELECTRICAL SPECIFICATIONS
Humidity/Temperature
UnitRangeRes.Acc.
< 70 %RH:
±4 %RH
%RH
Temp.
Air Flow
UnitRangeRes.
CMM 0.024~36000
CFM0.847~1271300
10 to 95
%RH
0~50°C0.1°C± 1.2°C
32~122°F 0.1°F± 2.5°F
0.1 %
RH
0.001/0.01/
0.1/1
0.001/0.01/
0.1/1/10 (x10)/
100 (x100)
≥70 %RH:
± (4% rdg
+1.2 %RH)
17
Page 18
ELECTRICAL SPECIFICATIONS
Dew point Temp.
UnitRangeRes. Remark
°C-25.3~49.0°0.1°
°F-13.5~120.0°0.1°
Wet bulb Temp.
UnitRangeRes. Remark
°C-5.4~49.0°0.1°
°F22.2~120°0.1°
Wind chill
UnitRangeRes.Accuracy
°C-0.4~44.2°0.1°± 2.0°C
°F15.0~112.0°0.1°± 3.6°F
* Wind chill value is in effect only when
the Temp. value <15°C and Air velocity
value >1.4 m/s.
* Calculate
from the
humidity/
Temp.
value
* Calculate
from the
humidity/
Temp. value
1819
Page 19
ELECTRICAL SPECIFICATIONS
Heat index
UnitRangeRes. Accuracy
°C0~100°0.1°± 2.0°C
°F32~212°0.1° ± 3.6°F
Effects of the heat index
(shade values)
°C°FNotes
Caution: Fatigue is
27~
80~
32°
90°
32~
90~
41°
105°
41~
105~
54°
130°
54°+ 130°+
* Exposure to full sunshine can increase
heat index values by up to 8°C (14°F)
possible with prolonged
exposure and activity.
Continuing activity could
result in heat cramps
Extreme caution:
Heat cramps, and heat
exhaustion are possible.
Continuing activity could
result in heat stroke
Danger:
Heat cramps, and heat
exhaustion are likely; heat
stroke is probable with
continued activity
Extreme danger:
Heat stroke is imminent
19
Page 20
WARRANTY
Sper Scientic warrants this product
against defects in materials and
workmanship for a period of ve (5)
years from the date of purchase,
and agrees to repair or replace any
defective unit without charge. If your
model has since been discontinued, an
equivalent Sper Scientic product will
be substituted if available. This warranty
does not cover probes, batteries, battery
leakage, or damage resulting from
accident, tampering, misuse, or abuse
of the product.
To obtain warranty service, ship
the unit postage prepaid to:
SPER SCIENTIFIC LTD.
7720 E Redeld Rd, Suite 7
Scottsdale, AZ 85260
The defective unit must be accompanied
by a description of the problem and your
return address. Register your product
online at www.sperscientic.com, or
return your warranty card within 10
days of purchase.
Revised 09/05/12
20
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.