The contents of this manual may
not be reproduced or transmitted
in any form or by any means
electronic, mechanical, or other
means that do not yet exist or
may be developed, including
photocopying, recording, or any
information storage and retrieval
system without the express
permission from Sper Scientic.
Sper Scientic
7720 E. Redeld Rd. Suite #7,
Scottsdale, AZ 85260
Tel: (480) 948-4448
Fax: (480) 967-8736
Web: www.sperscientic.com
23
Page 3
TABLE OF CONTENTS
1. INTRODUCTION . . . . . . 4
2. MATERIALS SUPPLIED. . .4
3. FEATURES . . . . . . . . . 5
4. FRONT PANEL
DESCRIPTION . . . . . . . 6
5. OPERATING
INSTRUCTIONS. . . . . . .7
Power on/off . . . . . . . . .7
LCD backlight on/off . . . . .7
Mode selection . . . . . . .7
Unit selection . . . . . . . . 8
Special attention for the
Humidity measurement . . . 9
Hold Function . . . . . . . 10
REC (Record) function . . 10
Auto power off disable . . . 11
6. BATTERY
REPLACEMENT. . . . . . 12
7. SPECIFICATIONS. . . . . 13
8. WARRANTY. . . . . . . . 16
3
Page 4
INTRODUCTION
For environmental testing
anywhere. Model 850025
combines an anemometer,
humidity meter and
thermometer into a single
compact unit. Features include
touch-tone buttons, min/max
and hold functions. Comes
ready to use with wrist strap,
instructions, battery and soft
carrying case.
MATERIALS SUPPLIED
Meter
Wristlet
CR 2032 DC 3V Battery
Soft Carrying Case
45
Page 5
FEATURES
• 3 professional environmental
instruments in 1: Air velocity,
Humidity and Temperature
• Lightweight, ergonomic design
• Wristlet design provides extra
protection to the instrument
• Low-friction ball bearing
mounted impeller design
provides high accuracy at
high and low air velocity
2. Power off: Press for > 3
seconds to turn meter off.
LCD backlight on/off
With the meter on, press
once. The LCD backlight will
light for 5 seconds, then shut off
automatically.
Mode selection
This meter offers 2
selectable modes:
a. Anemometer (Air velocity)
/Temperature
b. Humidity/Temperature
With the meter on, press HOLD
continuously and the Display will
show the following texts
in sequence:
7
Page 8
Display Mode text
An = Anemometer (Air velocity)/
Temperature
rH = Humidity/ Temperature
When the display shows the
desired mode, release HOLD
and the meter will set this mode
as the default.
An Mode Selection
REC button = Enter button
1. With the power on, press REC
for >3 seconds, the display
will show Unit. Release REC,
then press to scroll through
the available scales. After the
desired scale is selected, press
REC to save as the default.
2. The next screen displays
“dCdF” with the current
temperature scale selection
(°C or °F) below. Press to
89
Page 9
select the desired scale.
Press REC to save as
the default.
Note…
When rH is the selected mode,
you may only adjust the
temperature scale setting.
(°C or °F)
The selection scales
for all modes are:
MeasurementScales
m/s, Km/h,
Air Velocity
Temp. (Air velocity) °C/°F
Temp. (Humidity)°C/°F
mph, knot,
FPM
Note…
For the most accurate humidity
measurement, do not touch or
block the humidity sensor at any
time with your hand.
Hold Function
9
Page 10
Pressing Hold will freeze the
current reading on the display.
The HOLD symbol will be
displayed at the top of the
display window.
To release the Hold function,
press Hold again, the HOLD
indicator will disappear and the
current reading will be displayed.
REC (Record) function
The REC (Record) function will
record and display the maximum
and minimum readings.
1. Start the Record function
by pressing REC once.
The REC symbol will appear
on the display.
2. With the REC symbol on
the display:
a. Press REC once and the
Max symbol will appear on
1011
Page 11
the display along with the
current maximum value.
b. Press REC again, the MIN
symbol will appear on
the display along with the
current minimum value.
c. Clear the recorded MAX or
MIN value from the display
by pressing Hold once. The
MAX/MIN symbols and their
readings, will disappear from
the display. The meter will
return to the REC function
and continue recording.
d. To exit REC function press
REC button for >2 seconds.
Auto power off disable
In order to prolong the battery
life, this instrument has an Auto
Power Off function: the meter
will turn off if no buttons are
pressed for approximately
10 minutes.
11
Page 12
To disable the Auto Power Off
function, press REC and enter the
record function (page 10). The Auto
power off function will be disabled
until the record function is exited.
REPLACE BATTERY
1. When the LCD display
shows symbol, it is
time to replace the battery.
(Measurements may still
be made for several hours
after the low battery indicator
appears.)
2. Open the Battery Compartment
and remove the battery.
3. Install the battery (CR2032)
and replace the cover.
1213
Page 13
GENERAL SPECIFICATIONS
Display8 mm LCD display
Measurement1. Anemometer
(Air velocity)/
Temperature
2. Humidity/
Temperature
Operating
Humidity
Operating
Temperature
Over Input
Display
Power SupplyCR 2032 DC
Power
Consumption
Weight160 g (battery
Dim (HWD)4.7" x 1.8" x 1.2"
Standard
Accessories
Max. 80% RH
0 ~ 50°C
(32 ~ 122°F)
“- - - -”
3V battery
Approx.
DC 5 mA
included)
(120 x 45 x 20 mm)
Instruction Manual,
battery, soft case
13
Page 14
ELECTRICAL
SPECIFICATIONS
Air Velocity
UnitRangeRes.Acc.
ft/min80 ~ 39271
m/s0.4 ~ 20.00.1
km/h1.4 ~ 72.00.1
mph0.9 ~ 44.70.1
knots0.8 ~ 38.80.1
Temp.
°C/°F
ft/min: feet per minute
m/s: meters per second
km/h: kilometers per hour
mph: miles per hour
knots: nautical miles per hour
0 ~ 50°C0.1°C± 1.2
32 ~ 122°F0.1°F± 2.5
±3%
F.S.
1415
Page 15
ELECTRICAL
SPECIFICATIONS
Humidity/Temperature
UnitRangeRes.Acc.
< 70 %RH:
±4 %RH
%RH
10 to 95
%RH
0.1 %
RH
≥70 %RH:
± (4% rdg
+1.2 %RH)
Temp.
°C/°F
0~500.1°C ± 1.2°C
32~122 0.1°F± 2.5°F
15
Page 16
WARRANTY
Sper Scientic warrants this product
against defects in materials and
workmanship for a period of ve (5)
years from the date of purchase,
and agrees to repair or replace any
defective unit without charge. If your
model has since been discontinued, an
equivalent Sper Scientic product will
be substituted if available. This warranty
does not cover probes, batteries, battery
leakage, or damage resulting from
accident, tampering, misuse, or abuse
of the product.
To obtain warranty service, ship
the unit postage prepaid to:
SPER SCIENTIFIC LTD.
7720 E Redeld Rd, Suite 7
Scottsdale, AZ 85260
The defective unit must be accompanied
by a description of the problem and your
return address. Register your product
online at www.sperscientic.com, or
return your warranty card within 10
days of purchase.
Revised 08/23/12