Sper Scientific 850021 User Manual

Page 1
RH Anemometer Pen
850021
Instruction Manual
SPER
SPER
SPERSPER SCIENTIFIC
SCIENTIFIC
SCIENTIFICSCIENTIFIC
Page 2
TABLE OF CONTENTS
Features …………………………………………... 3
Front Panel Description ………………………….. 4
Measurement Procedures ….……………………. 5-9
Specifications ………………………………..……. 10-12
Battery Replacement …………………………..… 13
THIS PAGE INTENTIONALLY LEFT BLANK
Page 3
Sper Scientific warrants this product against
defects in materials and workmanship for a period
of five (5) years from the date of purchase, and
agrees to repair or replace any defective unit without charge. If your model has since been
discontinued, an equivalent Sper Scientific product
will be substituted if available. This warranty does
not cover probes, batteries, or damage resulting
from accident, misuse, or abuse of the product. In
order to obtain warranty service, simply ship the
unit postage prepaid to:
SPER SCIENTIFIC LTD.
7720 East Redfield, Suite 7
Scottsdale, AZ 85260
Email: info@sperscientific.com,
Phone: (480) 948-4448
Be sure to include your name, address, phone
number, and a detailed explanation of why you are
returning the item. Mail your warranty card within
10 days or register on line at:
www.sperscientific.com.
FEATURES
Anemometer units of measure: m/S, Km/h, FPM, mph,
Knots.
Humidity with Dew point measurement.
Temperature measurements in ºC and ºF.
Vane anemometer (built-in) for highly reliable wind
speed measurements.
Low-friction ball vane is accurate for both high and low
velocities.
Fast response time for all measurements.
One of the three modes can be displayed at one time:
Humidity/Temp., Humidity/Dew point and Anemometer/
Temp.
Bright LCD display.
Microprocessor circuit ensures high accuracy with spe-
cial functions and features.
Revised: 10/31/2007
Records Maximum and Minimum readings.
Durable compact ABS-plastic housing.
Auto power-off saves battery life.
Operates on 4 standard AAA alkaline batteries.
3
Page 4
FRONT PANEL DESCRIPTION
BATTERY REPLACEMENT
Figure 1
1 Vane
2 Humidity/Temp Sensor
3 Power () button
4 Hold ( ) & Unit button 5 REC () & Mode button
1. Replace the batteries when the low battery icon is displayed in the upper left corner of the LCD. Use 4 new AAA alkaline batteries.
2. To replace the batteries, open the Battery Cover by turn­ing counter-clockwise.
3. Ensure the Battery Cover is secured after replacing the batteries.
X
6 LCD Display
7 Battery Compartment
4
13
Page 5
SPECIFICATIONS
MEASURING PROCEDURE
Humidity & Dew Point
Humidity
Range 10% to 95% R.H,
Resolution 0.1 % R.H.
Accuracy ≥ 70% RH
± (3% reading + 1% RH) < 70% RH - 3% RH ± 3% RH
Dew point *
ºC Range -25.3 ºC to 48.9 ºC
Resolution 0.01 ºC
ºF Range -13.5 ºF to 120.1 ºF
Resolution 0.01 ºF
*
The Dew point display value is automatically calculated from the Humidity and Temperature measurements. Dew point accuracy is directly dependent upon the accuracy of the Humidity and Temperature measurements.
Mode Selection
1. Turn on the meter by pressing the Power button To turn the meter off, press the Power button again.
2. The meter has three modes that can be selected:
a. Humidity / Temperature b. Humidity / Dew Point c. Anemometer / Temperature
3. Press the Mode button for at least 2 seconds and both the upper and lower values will start to flash (see dia­gram below). Use the ▲ button to switch the upper dis­play unit, and use the button to switch the lower dis­play unit. Then press the  button to accept the se-
lected units.*
%RH
Value Flashing
60.9
12
Value Flashing
*
The most recent settings are stored when the power is turned off, and displayed again when power is turned back on.
25.9 ºC
5
Page 6
MEASURING PROCEDURE
SPECIFICATIONS
Unit Selection
1. Turn on the meter by pressing the Power button.
2. Press the Unit button for at least 2 seconds and both the upper and lower values will start to flash (see below). Use the ▲ button to switch the upper display unit, and use the button to switch the lower display unit. Then
press the
Value Flashing
button to accept the selected units.*
%RH
25.9 ºC
60.9
Value Flashing
Electrical Specifications
Anemometer (Air velocity)
Measure­ment
m/S 0.4 to 30.0 m/s 0.1 m/S
Km/h 1.4 to 108.0
FPM 80 to 5910 ft/
mph 0.9 to 67.0
Knots 0.8 to 58.3
Temperature
Range Resolution Accuracy
0.1 Km/h
km/h
1 Ft/min
min
0.1 mph
mph
0.1 knots
knots
≤ 20m/S : ± 3% F.S.
> 20 m/S : ± 4% F.S
(all measurements)
Measurement units:
Anemometer m/S, Km/h, FPM, mph, Knot
Temperature
Humidity %RH
Dew Point
*
The most recent settings are stored when the power is turned off, and displayed again when power is turned back
on.
ºC, ºF
ºC, ºF
6
Measuring Range 0 ºC to 50 ºC / 32 ºF to 122 ºF
Resolution 0.1 ºC / 0.1 ºF
Accuracy ±0.8 ºC / 1.5 ºF
11
Page 7
SPECIFICATIONS
MEASURING PROCEDURE
General Specifications
Display LCD size: 28mm x 19mm
Sensor Structure Anemometer—Vane probe with low
friction ball bearing design Humidity—Capacitance humidity sen­sor, semiconductor Temperature—Semiconductor
Sampling Time Approx. 1 second
Power off Auto or manual off
Operating Temperature
Operating Humidity
Power Supply 4 AAA alkaline batteries
Weight 182g / .4LB with battery incl.
Dimension 205 x 48 x 40mm
Accessories In­cluded
0 to 50º C
Less than 80% RH
8.1” x 1.9” x 1.6”
Instruction manual, soft carrying case and batteries
Anemometer Measurement
1. Turn on the meter by pressing the Power button.
2. Set the mode to display: Anemometer / Temperature: Upper display shows air velocity value and the lower display shows temperature.
Humidity Measurement
1. Turn on the meter by pressing the Power button.
2. Set the mode to display: Humidity / Temperature: Up­per display shows humidity value and the lower display shows temperature.
Dew point measurement
1. Turn on the meter by pressing the Power button.
2. Set the mode to display: Humidity / Dew point: Upper display shows humidity value and the lower display shows dew point.
10
7
Page 8
MEASURING PROCEDURE
MEASURING PROCEDURE
Data Hold
1. To hold the current reading on the LCD, press the Hold button. The LCD will show the HOLD symbol.
2. Press the Hold button again to resume active measure­ment.
Data Record (Maximum & Minimum Reading)
1. The data record function records the maximum and minimum readings. Press the REC button to start the Data Record function - REC shows on the display.
2. Press the REC button and the REC MAX symbol, along with the maximum value will appear on the LCD display.
3. Press the REC button again and the REC MIN symbol, along with the minimum value will appear on the LCD display.
4. To exit the memory record function, press the REC button for a minimum of 2 seconds. The display will revert back to the current reading, not showing REC.
When the LCD display shows REC MAX (or REC MIN), press the Hold button to delete the stored max (or min) value.
Auto Power Off Management
1. The meter has a built-in Auto Power Shut-off function in order to prolong battery life. The meter will switch off automatically if no buttons are pressed within 10 min­utes.
2. To disable this feature, select the memory record func­tion during measurement, by pressing the REC button.