agrees to repair or replace any defective unit
without charge. If your model has since been
discontinued, an equivalent Sper Scientific product
will be substituted if available. This warranty does
not cover probes, batteries, or damage resulting
from accident, misuse, or abuse of the product. In
order to obtain warranty service, simply ship the
unit postage prepaid to:
SPER SCIENTIFIC LTD.
7720 East Redfield, Suite 7
Scottsdale, AZ 85260
Email: info@sperscientific.com,
Phone: (480) 948-4448
Be sure to include your name, address, phone
number, and a detailed explanation of why you are
returning the item. Mail your warranty card within
10 days or register on line at:
www.sperscientific.com.
FEATURES
• Anemometer units of measure: m/S, Km/h, FPM, mph,
Knots.
• Humidity with Dew point measurement.
• Temperature measurements in ºC and ºF.
• Vane anemometer (built-in) for highly reliable wind
speed measurements.
• Low-friction ball vane is accurate for both high and low
velocities.
• Fast response time for all measurements.
• One of the three modes can be displayed at one time:
Humidity/Temp., Humidity/Dew point and Anemometer/
Temp.
• Bright LCD display.
• Microprocessor circuit ensures high accuracy with spe-
cial functions and features.
Revised: 10/31/2007
• Records Maximum and Minimum readings.
• Durable compact ABS-plastic housing.
• Auto power-off saves battery life.
• Operates on 4 standard AAA alkaline batteries.
3
Page 4
FRONT PANEL DESCRIPTION
BATTERY REPLACEMENT
Figure 1
1 Vane
2 Humidity/Temp Sensor
3 Power (▲) button
4 Hold ( ) & Unit button
5 REC () & Mode button
1. Replace the batteries when the low battery icon
is displayed in the upper left corner of the LCD.
Use 4 new AAA alkaline batteries.
2. To replace the batteries, open the Battery Cover by turning counter-clockwise.
3. Ensure the Battery Cover is secured after replacing the
batteries.
X
6 LCD Display
7 Battery Compartment
4
13
Page 5
SPECIFICATIONS
MEASURING PROCEDURE
Humidity & Dew Point
Humidity
Range 10% to 95% R.H,
Resolution 0.1 % R.H.
Accuracy ≥ 70% RH
± (3% reading + 1% RH)
< 70% RH - 3% RH
± 3% RH
Dew point *
ºC Range -25.3 ºC to 48.9 ºC
Resolution 0.01 ºC
ºF Range -13.5 ºF to 120.1 ºF
Resolution 0.01 ºF
*
The Dew point display value is automatically calculated
from the Humidity and Temperature measurements. Dew
point accuracy is directly dependent upon the accuracy of
the Humidity and Temperature measurements.
Mode Selection
1. Turn on the meter by pressing the Power button To
turn the meter off, press the Power button again.
2. The meter has three modes that can be selected:
a. Humidity / Temperature
b. Humidity / Dew Point
c. Anemometer / Temperature
3. Press the Mode button for at least 2 seconds and both
the upper and lower values will start to flash (see diagram below). Use the ▲ button to switch the upper display unit, and use the button to switch the lower display unit. Then press the button to accept the se-
lected units.*
%RH
Value Flashing
60.9
12
Value Flashing
*
The most recent settings are stored when the power is
turned off, and displayed again when power is turned back
on.
25.9 ºC
5
Page 6
MEASURING PROCEDURE
SPECIFICATIONS
Unit Selection
1. Turn on the meter by pressing the Power button.
2. Press the Unit button for at least 2 seconds and both the
upper and lower values will start to flash (see below).
Use the ▲ button to switch the upper display unit, and
use the button to switch the lower display unit. Then
press the
Value Flashing
button to accept the selected units.*
%RH
25.9 ºC
60.9
Value Flashing
Electrical Specifications
Anemometer (Air velocity)
Measurement
m/S 0.4 to 30.0 m/s 0.1 m/S
Km/h 1.4 to 108.0
FPM 80 to 5910 ft/
mph 0.9 to 67.0
Knots 0.8 to 58.3
Temperature
Range Resolution Accuracy
0.1 Km/h
km/h
1 Ft/min
min
0.1 mph
mph
0.1 knots
knots
≤ 20m/S :
± 3% F.S.
> 20 m/S :
± 4% F.S
(all measurements)
Measurement units:
Anemometer m/S, Km/h, FPM, mph, Knot
Temperature
Humidity %RH
Dew Point
*
The most recent settings are stored when the power is
turned off, and displayed again when power is turned back
Instruction manual, soft carrying case
and batteries
Anemometer Measurement
1. Turn on the meter by pressing the Power button.
2. Set the mode to display: Anemometer / Temperature:
Upper display shows air velocity value and the lower
display shows temperature.
Humidity Measurement
1. Turn on the meter by pressing the Power button.
2. Set the mode to display: Humidity / Temperature: Upper display shows humidity value and the lower display
shows temperature.
Dew point measurement
1. Turn on the meter by pressing the Power button.
2. Set the mode to display: Humidity / Dew point: Upper
display shows humidity value and the lower display
shows dew point.
10
7
Page 8
MEASURING PROCEDURE
MEASURING PROCEDURE
Data Hold
1. To hold the current reading on the LCD, press the Hold
button. The LCD will show the HOLD symbol.
2. Press the Hold button again to resume active measurement.
Data Record (Maximum & Minimum Reading)
1. The data record function records the maximum and
minimum readings. Press the REC button to start the
Data Record function - REC shows on the display.
2. Press the REC button and the REC MAX symbol, along
with the maximum value will appear on the LCD display.
3. Press the REC button again and the REC MIN symbol,
along with the minimum value will appear on the LCD
display.
4. To exit the memory record function, press the REC
button for a minimum of 2 seconds. The display will
revert back to the current reading, not showing REC.
When the LCD display shows REC MAX (or REC MIN),
press the Hold button to delete the stored max (or min)
value.
Auto Power Off Management
1. The meter has a built-in Auto Power Shut-off function in
order to prolong battery life. The meter will switch off
automatically if no buttons are pressed within 10 minutes.