Sper Scientific 850014 User Manual

Page 1
Mini Sound Meter
850014
Instruction Manual
Page 2
TABLE OF CONTENTS
1. INTRODUCTION . . . . . . . . . . . 2
2. PANEL DESCRIPTION . . . . . . . . 3
3. OPERATING INSTRUCTIONS . . . . 4
3-A. Measuring Procedures . . . . . . 4
3-B. Hold Function . . . . . . . . . . 5
3-C. Min/Max Function . . . . . . . . 5
3-D. Calibration . . . . . . . . . . . . 6
4. AUTO POWER OFF . . . . . . . . . . 6
5. SPECIFICATIONS. . . . . . . . . . . 7
6. OPTIONAL ACCESSORIES. . . . . . 8
7. WARRANTY. . . . . . . . . . . . . . 8
1. INTRODUCTION
2
Page 3
2. PANEL DESCRIPTION
3
1.Windscreen
2. Microphone (remove windscreen to expose the microphone tip)
3. LCD Display
4. A/C (weighting)
5. Hold
6. Fast/Slow (response)
7. Backlight
8. Max/Min
9. Power
10. Battery
Compartment (on back)
Page 4
3. OPERATING INSTRUCTIONS
Keep the microphone dry and avoid strong vibrations. Use the WINDSCREEN (1) at wind speeds over 10m/sec.
3-A. MEASURING PROCEDURE
• Turn the meter on by pressing the POWER (9) button. The meter defaults to the A frequency and FAST response.
• Press the A/C (4) button to toggle between frequency scales. The A scale is shown as “dBA” and the C scale is shown as “dBC”. Select the A scale to simulate the human ear’s response. A is generally used for environmental measurements. The C scale approximates a
at response and is typically used to measure
low-frequency machinery noise where the target sound level is already known.
• Press the FAST/SLOW (6) button to toggle between response-time scales. Select FAST for general applications and SLOW to check the
avg. level of uctuating noise, like machinery.
• Point the MICROPHONE (2) at the sound
source. The decibel level is displayed.
Press the BACKLIGHT (7) button to turn
on/off the illuminated display. The backlight auto-matically turns off after 15 seconds.
Press the POWER (9) button to turn the meter off.
4
Page 5
3-B. HOLD FUNCTION
With the meter on, press the HOLD (5) button to display “HOLD” and the last dB reading. Press HOLD (5) again to exit this function.
3-C. MAX/MIN FUNCTION
The Max/Min dB readings are continually updated as soon as the meter is turned on. These readings are reset when you exit the Max/Min function, or when the meter is turned off.
• With the meter on, press the MAX/MIN (8) button once to display “MIN” and the minimum recorded dB level. The display will be updated when there is a lower dB reading.
• Press the MAX/MIN (8) button again to display “MAX” and the maximum (peak) recorded dB level. The display will be updated only when the max (peak) dB level is exceeded.
• To exit this function, press and hold the MAX/MIN (8) button for at least 2 seconds, then release. The current dB reading is displayed.
NOTE: When the meter is rst turned on, there may be a dB “spike” that could inuence the
maximum (peak) reading. To ensure accuracy, enter and exit the MAX/MIN function once to reset the recorded dB levels.
5
Page 6
3-D. CALIBRATION
Use Sper Scientic Acoustical Calibrator
850016 (or equivalent) to calibrate the meter. Perform the calibration at temperatures between 58~78°F (15~25°C). The calibrator and meter should be at the same temperature.
• Remove the WINDSCREEN (1) and turn on the meter by pressing the POWER (9) button.
• Turn the acoustical calibrator on to 94.0 dB
and place it onto the MICROPHONE (2).
• With the meter in FAST response mode and A (dBA) weighting, press and hold the A/C (4) button.
• Without releasing the A/C (4) button, press and hold the HOLD (5) button. The display will go blank.
• Release both buttons and “94.0” ± 0.2 is displayed.
• The calibration process can be repeated
until the meter reads the desired value.
• This completes the calibration process.
4. AUTO POWER OFF
If no buttons are pushed for about 3 minutes, the meter will automatically turn off.
6
Page 7
5. BATTERY REPLACEMENT
+
• Turn off the meter when the low battery icon is displayed.
• Slide BATTERY COMPARTMENT (10) cover down to install a fresh 9V battery.
• Replace the cover.
• Expected battery life is about 50 hrs.
6. SPECIFICATIONS
Display 3/4” high digits, 4-digit LCD,
display updates every 0.5 seconds.
Range dynamic range: 50dB
auto-ranging: 30~130d B A (dBA) weighting: 30~130dB C (dBC) weighting: 35~130dB
Resolution 0.1dB
Accuracy ±1.5dB
Frequency 31.5 HZ ~ 8KHZ
Response Fast = 125mS, Slow =1 sec
Operating Environ.
Storage Environ.
Weight & Dimension
41~104°F (5~40°C) <80% RH & up to 2000m above sea level
13~140°F (-10°C~60°C) & < 70%RH
6 oz (170 g)
8" x 2⅛" x 1½”, 200 x 55 x 38 mm
7
Page 8
7. OPTIONAL ACCESSORIES
850016 Acoustical Calibrator 840091 Windscreen 850000 Rubber Boot
8. WARRANTY
Sper Scientic warrants this product against
defects in materials and workmanship for ve (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been
discontinued, an equivalent Sper Scientic
product will be substituted if available. This warranty does not cover damage resulting from accident, misuse, or abuse of the product.
To obtain warranty service, ship the unit postage prepaid to:
SPER SCIENTIFIC LTD. 8281 East Evans Road, Suite #103 Scottsdale, AZ 85260
The defective unit must be accompanied by a description of the problem and your return address. Register your product online at
www.sperscientic.com, or return your
warranty card within 10 days of purchase.
REV 07/11/13
8
Loading...