The contents of this manual may not be
reproduced or transmitted in any form or by any
means electronic, mechanical, or other means
that do not yet exist or may be developed,
including photocopying, recording, or any
information storage and retrieval system without
the express permission from Sper Scientific.
WARRANTY
Sper Scientific warrants this product against
defects in materials and workmanship for five (5)
years from the date of purchase and agrees to
repair or replace any defective unit without charge. If
your model has since been discontinued, an
equivalent Sper Scientific product will be substituted, if
available. This warranty does not cover damage
resulting from accident, misuse, or abuse of the
product. To obtain warranty service, ship the unit
postage prepaid to:
SPER SCIENTIFIC LTD.
7720 E. Redfield Rd, Suite 7,
Scottsdale, AZ 85260
Email: info@sperscientific.com
Be sure to include a description of the problem and
your return address. Register your product online at
www.sperscientific.com or return your warranty card
within 10 days.
7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260
Tel: (480) 948-4448 Fax: (480) 967-8736
Web: www.sperscientific.com
- 23 -
Page 3
OPTIONAL ACCESSORIES
840090 Water Resistant Instrument Pouch
840092 Bench-Top Tripod
840093 Field Tripod
CONTENTS
INTRODUCTION ............................... 4
FEATURES ....................................... 5
850010) is a light-weight, portable instrument
that measures damaging UV (ultraviolet) light in
both natural and manmade environments.
The UV Light Meter measures short wave UV-C
light for applications such as UV light fume
hoods, UV sterilization, industrial glass and nondestructive testing.
You can use the meter almost anywhere to
determine UV light intensity and avoid the
harmful effects of overexposure.
UV Range 1
(Low Illumination)
UV Range 2
(High Illumination)
Resolution
Accuracy
Wavelength
Calibration Point
Temperature
Range
Meter
Dimensions
Weight
Sensor
Dimensions
1 W/cm2 ~ 9999 W/cm2
0.01 mW/cm2 ~
40.00 mW/cm2
2
1W/cm
and
0.01 mW/cm2
±4% ±1 digit (at 23 ±5°C)
220 ~ 275 nm
254 nm
0 ~ 50°C
6” x 2” x 1½”
(145 x 55 x 40 mm)
4.4 oz (135 g)
Diameter = 35 mm
H = 25.5 mm
- 4 -
- 21 -
Page 5
MAINTENANCE
FEATURES
1. Dampen a sponge or soft cloth with soap
and water to clean the housing.
2. Take care to prevent any liquids or moisture
from getting inside the unit during cleaning.
Tripod Mounting Socket
High and low measurement range in
milliwatts per square centimeter (mW/cm2)
or microwatts per square centimeter (W/
cm2)
Backlit LCD
Magnetic Mount
Simultaneous Display of Minimum,
Maximum, Average and Recorded Data
Zero Point Reset
Hold Function
4 Digit Dual Display
20 Points Memory
Automatic Measuring
Low Battery Indicator
- 5 - - 20 -
Page 6
MATERIALS SUPPLIED
BATTERY REPLACEMENT
Meter
UV Probe
Magnetic Mount
9 Volt Battery
Instruction Manual
Hard Carrying Case
This unit requires one 9 Volt battery. The
icon indicates a low battery. To replace:
1. Slide off battery cover from the back of the
unit.
2. Insert a 9V battery ensuring correct polarity.
3. Replace battery cover.
- 6 -
- 19 -
Page 7
UVC SENSOR
Portable Handheld Use
1. Upper casing
2. Sensor
3. Lower casing
x 1
x 1
LCD DISPLAY
x 1
4. Self-tapping
screws
Note…
To avoid wearing the
screw holes, limit the
number of times you
assemble and
disassemble the
probe.
x 5
1. Mode
2. Primary Reading
3. Data Log
4. Auto Mode
5. Memory Review
6. Data Hold
7. Record
8. MAX/MIN/AVG
9. Secondary Reading
10. Time Unit
11. Unit of Measure
12. UV Type
13. Low Battery
- 18 - - 7 -
Page 8
BASIC FUNCTIONS
Power On/Off
1. Press and hold the HOLD button for 2 seconds to turn the meter on. All symbols on
the LCD will appear for 1 second.
2. Press and hold the HOLD button for 2 seconds to turn the meter off. All symbols on
the LCD will appear for 1 second. Release
HOLD button.
Reading the LCD Display
1. The primary display indicates measurement
value.
UVC SENSOR
Relative Spectral Sensitivity (%)
Wavelength (nm)
Calibration
Point
2. The secondary display indicates the
advanced functions or data recording.
CAUTION:
THE UV SENSOR IS A SENSITIVE INSTRUMENT.
TO PREVENT PREMATURE AGING AND THERMAL
DESTRUCTION OF THE SENSOR, USE THE SENSOR
FOR SHORT-TERM MEASUREMENT IN A SPLASH-
PROOF ENVIRONMENT ONLY. THE HOUSING
TEMPERATURE MUST NOT EXCEED 50°C.
STORE IN A DRY ENVIRONMENT.
- 17 - - 8 -
Page 9
MEMORY
BASIC FUNCTIONS
were automatically recorded, “AUTO”
appears next to “MEM” during the recall.
4. As you scroll through data points 0 to 20, the
saved minimum, maximum, or average value
appears on the secondary display.
5. The “MAX”, “MIN” or “AVG” icon will appear
on the bottom of the LCD next to the data
point number to indicate whether the
secondary display represents a maximum,
minimum, or average value for that data
point. If none of these icons appear, the value represents a stored value at that data
point that is not a minimum, maximum or
average value.
Clear Data
1. Press MODE to select Zero Mode.
2. Press M to clear all 20 stored data points.
Meter Function Flow Chart
1. Press MODE to choose the main function
(MAX/MIN/AVG, Zero, Unit, Type or Time).
MAX/MIN/AVG Mode is Normal Mode for
this meter and has several sub-functions as
indicated in the diagram below.
- 16 -
- 9 -
Page 10
MODE AND UNIT SELECTION
MEMORY
Mode Selection
1. Press MODE continuously to cycle through
MAX/MIN/AVG, Zero, Unit, Type, and Time
Modes, respectively.
Maximum, Minimum and Average
(Normal Mode)
1. Press MODE continuously to cycle through
modes until you reach MAX/MIN/AVG.
2. The current measured value appears on the
primary display.
3. To view minimum, maximum or average
values of the current reading, press S
continuously to select subcategory modes of
None, Maximum hold, Minimum hold, and
Average hold, respectively.
4. Maximum, minimum and average values will
appear and freeze on the secondary display
and will update only when a new maximum,
- 10 -
To Auto Record:
1. In Normal Mode, press and hold M for 2 seconds. “AUTO” appears next to “REC” on
the LCD. As soon as the meter reaches 20
data points, the unit will turn off.
Recorded data includes: Irradiation intensity,
Max/Min/Avg and unit of measure
2. Press M to cancel Auto-Record Mode.
Memory Recall
1. In Normal Mode, press HOLD.
2. Press M to enter Memory Mode. “MEM” will
appear above “HOLD” on the LCD.
3. Press S to review data points 0 to 20 on the
secondary display. Data point 0 indicates the
set time interval between readings when in
Auto-Record Mode. (Refer to “Interval Time
Setting” section for instructions.) If the data
- 15 -
Page 11
MEMORY
MODE AND UNIT SELECTION
Manual Recording
In Normal Mode, press M to store the current
value that appears on the primary display. The
flashing DATA(01~20) icon stops flashing for 2
seconds and moves to the next storage
location. (Refer to Maximum, Minimum and
Average/Normal Mode on pages 10-11 for
instructions on saving max, min, and avg
values.)
Auto Recording
To utilize auto recording, you must first set an
interval time for recording measurement values.
Interval Time Setting
1. Press MODE continuously to cycle through
modes until you reach Time Mode.
2. Continuously press S to select an interval
time for auto recording of 1, 2, 5, 10, 30 seconds or 1, 3, 5, 10 minutes.
minimum, or average value is reached on
the primary display. Then the secondary
display updates automatically. The average
value on the secondary display updates
according to the detected maximum and
minimum values of the current reading.
4. Press M to save the current, max, min, or
avg value for each data point and the meter
will move to the next data point. The stored
data can hold either one current, max, min,
or avg value for each data point.
5. Press S to reset.
Data Hold
1. While in Normal Mode, press HOLD to
freeze the secondary display value. “HOLD”
will appear on the bottom left corner of the
LCD.
2. Press HOLD to cancel Hold Mode.
- 14 -
- 11 -
Page 12
MODE AND UNIT SELECTION
MODE AND UNIT SELECTION
Zero Adjustment
1. Press MODE continuously to cycle through
modes until you reach Zero Mode.
2. Cover the sensor. If the main display has a
reading other than zero, perform the zero
adjustment.
3. Cover the sensor and press S to zero adjust.
The secondary display indicates the
adjustment value for your reference.
4. Press and hold S for 1 second to clear the
adjustment value.
Note…
When the adjustment value is over 10 W, the
measurement value cannot be offset. The main
display will show the above range reading, and
the secondary display will show “-Err.” Repeat
the zero adjustment procedure or contact Sper
Scientific.
5. In Zero Mode, press M to clear data points 0
to 20.
Unit Selection
1. Press MODE continuously to cycle through
modes until you reach Unit Mode.
2. Press S to choose the unit of measure: W/
cm2 or mW/cm2.
Type Selection
This function is reserved for use in future
models.
- 12 - - 13 -
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.