INSTRUCTIONS
1. Open the battery compartment and remove the tab between the battery and the contact point.
2. Select lap or cumulative time by pressing the MODE (blue) button. The upper display
ashes the mode.
4. Press the SPLIT/LAP/RESET (red) button to record the lap or split time.
5. To reset the display to zero, press the
STOP (green) button, then press the RESET (red) button.
The stopclock has three 4 mm sockets for external triggering. These should be connected as follows:
Red = Reset Blue = Neutral Green = Start/Stop
Precautions: Do not use in environments
which are very hot or humid. Do not clean with abrasive or corrosive substances. Do not drop or shake vigorously. Do not open the unit.
Page 3
Ruggedly design for prolonged use as both a bench-top count-up timer and a stopclock.
Non-skid feet keep the unit rmly in place during
use, yet it is small and light enough to be easily moved around the lab as needed. A large LCD and buttons make it easy to operate. Counts­up to 10 hours with 1/100th second resolution in selectable cumulative or interval split modes. Comes complete with one AA battery and two cables for connection to an external trigger such as a photo gate. This unit is CE approved
and available with NIST traceable certicate of
calibration (810032C).
External Triggering Sockets
Battery Compartment (bottom)
External Triggering Cables
MODE (blue) button
START/STOP (green) button
SPLIT/LAP/RESET
(red) button
Page 4
SPECIFICATIONS
Range Counts up to 10 hours
Resolution 1/100th SEC
Accuracy ±3 SEC / 24 hrs
Dimensions 4½” x 4” x 2” (120 x 100 x 50 mm)
Weight 7 oz (210 g)
WARRANTY
Sper Scientic warrants this product against defects in materials and workmanship for a period of ve (5) years from the date
of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an
equivalent Sper Scientic product will be substituted if available.
This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will break the waterproof seal and void the warranty. To obtain warranty service, ship the unit postage prepaid to:
Sper Scientic Ltd.
8281 E. Evans Rd., Suite #103, Scottsdale, AZ 85260
(480) 948-4448
The defective unit must be accompanied by a description of the problem and your return address. Register your product online
at www.sperscientic.com, or return your warranty card within
10 days of purchase.
07/11/13
Loading...