FEATURES
99 minute - 59 second count-down timer
Audible and/or flashing LED backlight visible alarm
Auto-off after 10 minutes of inactivity
Pre-alarms at the final 5 minute and 3 minute intervals
DESCRIPTION: There are four buttons: START/STOP, VOLUME CONTROL, SECOND and MINUTE.
99
SET THE TIMER: Press the MIN and SEC buttons to set the count-down time.
START/STOP: Press the START/STOP button to begin the count-down. Upon reaching zero, the LCD backlight will flash and the alarm will sound (if turned on) for 30 seconds. While alarming, press the START/STOP button to cancel the alarm and recall the current timer setting.
PAUSE: Press the START/STOP button to pause/resume the count-down.
start/stop volume control
M s
59
sec clear min
CLEAR THE CURRENT SETTING: Press and hold both the MIN and SEC buttons for at least 2 seconds until zeros are displayed. Note: In count-down mode, pause the count-down before clearing. While alarming, press the START/STOP button before clearing. After the alarm has ended in overtime mode (below), press the START/ STOP button for at least 3 seconds to recall the timer setting before clearing.
OVERTIME: When the count-down has completed, the timer will count-up to a maximum of 20 minutes overtime. Press the START/ STOP button for at least 3 seconds to recall the timer setting before clearing.
SLEEP MODE: The display will turn off automatically and enter into sleep mode after 10 minutes of inactivity. Press any button to exit sleep mode.
BATTERY REPLACEMENT: Open the battery cover and insert three (3) 1.5V AAA alkaline batteries ensuring proper polarity (+ and -). Close the battery cover.
WARRANTY
Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the timer to expose its electronics will void the warranty. To obtain warranty service, ship the unit postage prepaid to: