![](/html/00/00cc/00cc4a6e791ddadc0b1d4de4bc3fa3d5df4661354199a7feb9886fb0b13e46d3/bg1.png)
QM75 Quick Measure
Distance Meter
User Guide
•
Introduction
Thank you for choosing the Spectra Precision QM75 from the Trimble
family of precision products. This easy-to-use distance measuring tool
will allow you to measure distances quickly, accurately and reliably.
Before using the Quick Measure, read this operator’s manual carefully.
Included is information about operation, safety and maintenance. Also
included are CAUTIONs and NOTEs to highlight important
considerations. CAUTION indicates a hazard or unsafe practice that
could result in a minor injury or property damage. A NOTE indicates
important information to help the user employ the product efficiently.
Ensure that the operating instructions are with the laser distance meter
when it is given to other persons.
Your comments and suggestions are welcome; please contact us at:
Features
1. Protective overmolding
2. Liquid Crystal Display (LCD) -
1
Illuminated with 20 second shutoff
3. Measure Button
4. Power On/Off Button
2
5. Measuring Reference - measurements
are from bottom of unit
3
4
5
6. Laser Exit and Receiving Lens
Trimble Spectra Precision Division
Features - LCD Detail
Previous measurement value
Units of measure
Result measurement value
Laser switched on
Battery status
8261 State Route 235
Dayton, Ohio 45424 USA
Phone: +1 (937) 203-4419
+1 (800) 527-3771
6
Menu On
Temperature too high or too low
Fax: +1 (937) 482-0030
Internet: www.trimble.com/spectra
7. Pouch with belt loop
Unfavorable signal conditions
8. 2 x AAA batteries
9. User Guides
Ambient light at target too bright
www.trimble.com/spectra
Batteries - Installation
1. Open the battery compartment.
2. Remove the batteries from the packaging and insert them in the
tool.
NOTE
When installing batteries note the positive (+) and
negative (-) markings on the housings
3. Close the battery compartment cover.
Battery disposal - Some areas have regulations regarding the disposal
of batteries. Be sure to dispose of discharged batteries properly.
CAUTION: The batteries should be removed when storing the laser
more than 30 days.
– 2 – – 3 – – 4 –
General Operation
Single distance measurement
1) Switch on the laser beam by pressing the Measure Button.
2) Point the laser dot to the surface to be measured. (Distance is
measured from bottom of the tool).
3) Press the Measure Button once again. The measured distance will
be displayed.
4) Press the Power On/Off Button to switch off.
Continuous measurement
1) Press and hold the Measure Button for 2 seconds to activate
continuous measuring mode. The tool beeps during continuous
measure mode if beeper is turned on.
2) Press the Measure Button again to stop continuous measure.
(It does not matter if the Quick Measure is On or Off. It will always
switch to continuous measurement). During continuous measurement,
the distances are recalculated and displayed about 8 to 15 times per
second, depending upon the reflectivity of the target surface. When
continuous measure is stopped, the last valid distance measurement is
displayed on the result line.
7
Power on/off options
8 9
1) The Quick Measure is designed to allow quick measurements by
pressing the Measure Button to switch on the tool and activate the
laser. In this case, measurement is accomplished when the Measure
Button is pressed the second time.
2) It is also possible to use the power button to switch on the tool. In
this case, the Measure Button must be pressed once to activate the laser
and a second time to accomplish a measurement.
Settings menu (to change sound and unit of measure)
1) With the tool switched off, press and hold the Power On/Off Button
for approximately 2 seconds to enter menu mode.
2) Press the Measure Button to switch the beep signal On or Off.
3) Press the Power On/Off Button to access the measuring units
settings.
4) Press the Measure Button repeatedly to scroll through the choice of
units. Available measure units:
mm m in ft yd 1/8 ft 1/16 ft 1/8 in 1/16 in
5) To close the menu, press and hold the Power On/Off Button for
approximately 2 seconds. The tool is switched off and settings saved.
Contact service
Specifications
Measuring Range 0.3 to 70 m (1 to 230 feet)
Accuracy ± 1.5 mm typical (± 1/16 inch)
Functions Individual measure and continuous measure
Display Illuminated LCD showing distance, operating
and battery status
Automatic cut o laser - 1 minute, product 10 minutes
Battery life 8000 measures
Operating temperature -10⁰C to +50⁰C (14⁰F to 122⁰F)
Storage temperature -30⁰C to +70⁰C (-22⁰F to 158⁰F)
Power supply 2 x AAA 1.5V
Power indication LCD 4 segments - 100%, 75%, 50%, 25%
Laser Safety Class II as per EN 60825-1:2007; IEC 60825-
1:2007 CFR 21 § 1040 (FDA)
Laser Type / Power 635nm visible red / < 1 mW
Dimensions 34 x 42 x 125 mm (1.34 x 1.65 x 4.92 in)
Weight 144 g (5.0 oz) with batteries
Dust and Water resistance IP 55 protection against dust and water jets
IEC 529
Drop Performance 1.5 m (5 ft) onto concrete
– 5 – – 6 –
– 7 –
– 8 –
![](/html/00/00cc/00cc4a6e791ddadc0b1d4de4bc3fa3d5df4661354199a7feb9886fb0b13e46d3/bg2.png)
General Care, Safety And Storage
General safety rules
a) Check the condition of the tool before use.
b) The user must check the accuracy of the tool after it has been
dropped or subjected to other mechanical stresses.
c) Although the tool is designed for the tough conditions of jobsite use,
as with other measuring instruments it should be treated with care.
Do not use prisms or mirrored surfaces
Distances can be measured from all stationary targets without a highly
reflective surface, i.e. concrete, stone, wood, plastic, paper, etc. The use
of prisms or other highly reflective targets is not permissible and, if
attempted, may falsify the results.
Calibration Check
It is recommended to occasionally check the calibration of the tool.
1) Select a known measure distance about 1 to 5 meters (3 to 15 ft) that
does not change over time.
2.) Measure the distance 10 times. Calculate the mean deviation from
the actual distance. The measured mean deviation should be less than
the typical accuracy tolerance of
± 1.5 mm (± 1/16 in)
– 9 – – 10 – – 11 – – 12 –
Cleaning and drying
1. Blow dust off the lens.
2. Do not touch the lens with the fingers.
3. Use only a clean, soft cloth for cleaning. If necessary, moisten the
cloth slightly with pure alcohol or a little water.
NOTE
Do not use any other liquids as these may damage the plastic
components.
Storage
The temperature limits for storage of your equipment must be observed,
especially in winter / summer.
Remove the tool from its pouch if it has become wet. The tool, its
carrying case and accessories should be cleaned and dried (at maximum
40°C). Repack the equipment only once it is completely dry. Check the
accuracy of the equipment before it is used after a long period of storage
or transportation.
Transport
Use the original packaging or packaging of equivalent quality for
transporting or shipping your equipment.
CAUTION
Always remove the batteries before shipping the tool.
Trouble Shooting
Fault Possible cause Remedy
e unit can’t be switched on. e batteries are exhausted. Replace the batteries.
Incorrect battery polarity. Insert the batteries correctly and close the battery
e button is faulty. Contact Service
No distances displayed by the unit. Measure Button was not pressed. Press the Measure Button.
Unit was not switched on Press the Measure Button.
Faulty display. Contact Service
Frequent error messages or the unit doesn’t
measure.
Temperature indicator - symbol in the display
Unfavorable signal conditions - symbol in the
display
General hardware fault - symbol in the display Hardware fault
e target surface is too brightly lit by the sun. Measure from the other direction – sun from behind.
e target surface is too shiny. Take measurements from less shiny surfaces.
e target surface is too dark. Use a lighter colored surface
Bright sunlight towards the tool. Shade the unit.
Temperature too high (>+50 °C / 122 °F) Allow the unit to cool down.
Temperature too low (<-10 °C / 14 °F) Allow the unit to warm up.
Insucient reected laser light. Observe the minimum measuring distance (>200
compartment cover.
mm / 8 inch from the front edge of the unit);
clean the lenses; take the measurement from a
dierent surface or use a target plate.
Switch the unit o and on again.
Laser Safety
Use of this product by people other than those trained on this product
may result in exposure to hazardous laser light.
• Do not remove warning labels from the unit.
• The QM75 is a Class 2M (635 nm) laser product .
• Never look into the laser beam or direct it to the eyes of other people.
• Always operate the unit in a way that prevents the beam from getting
into people‘s eyes.
– 13 –
Warranty
Trimble warrants the Quick Measure QM75 to be free of defects in
material and workmanship for a period of 3 years. For the first 2 years,
Trimble or its authorized Dealer or Service Center will repair or replace,
at its option, any defective part, or the entire product, for which notice
has been given during the warranty period. For the 3rd year, an
exchange fee may apply. This warranty period is in effect from the date
the system is delivered by Trimble or its authorized Dealer to the
purchaser, or is put into service by a Dealer as a demonstrator or rental
component.
Any evidence of negligent or abnormal use, or any attempt to repair
equipment by other than factory-authorized personnel or Trimble
certified or recommended parts, automatically voids the warranty.
The foregoing states the entire liability of Trimble regarding the
purchase and use of its equipment. Trimble will not be held responsible
for any consequential loss or damage of any kind.
This warranty is in lieu of all other warranties, except as set forth above,
including an implied warranty. Merchantability of fitness for a
particular purpose is hereby disclaimed.
Customers should send products to the nearest authorized Factory,
Dealer or Service Center for warranty repairs, freight prepaid. In
countries with Trimble Service Subsidiary Centers, the repaired products
will be returned to the customer, freight prepaid.
– 14 – – 15 –
Service Request
To locate your local dealer or authorized Trimble Service Center outside
the U.S.A for service, accessories, or spare parts, contact one of our
offices listed below.
North-Latin America
Trimble / Spectra Precision Division
8261 State Route 235
Dayton, Ohio 45424-6383
U.S.A.
(888) 527-3771
(Toll Free in U.S.A.)
+1-937-203-4419 Phone
+1-937-482-0030 Fax
www.trimble.com/spectra
Europe
Trimble Kaiserslautern GmbH
Am Sportplatz 5
67661 Kaiserslautern
GERMANY
Tel +49-(0)6301-71 14 14
Fax +49-06301-32213
Africa & Middle East
Trimble Export Middle-East
P.O. Box 17760
JAFZ View, Dubai
UAE
+971-4-881-3005 Phone
+971-4-881-3007 Fax
Trimble Navigation Singapore PTE Ltd.
Asia-Pacific
80 Marine Parade Road, #22-06
Parkway Parade
Singapore, 449269
+65 6348 2212 Phone
+65 6348 2232 Fax
China
Trimble Beijing
Room 2805-07, Tengda Plaza,
No. 168 Xiwai Street
Haidian District
Beijing, China 100044
+86 10 8857 7575 Phone
+86 10 8857 7161 Fax
www.trimble.com.cn
Declarations
We declare, on our sole responsibility, that this product complies with
the following directives and standards:
EN 50081-1, EN 61000-6-2, 2004/108/EC.
Designation: Laser range meter
Type: QM75
Notice to Our European Union Customers
For product recycling instructions and more information,
please go to: www
To recycle Trimble WEEE, call: +31 497 53 2430, and ask for the “WEEE
associate,” or
mail a request for recycling instructions to:
Trimble Europe BV
c/o Menlo Worldwide Logistics
Meerheide 45
5521 DZ Eersel, NL
.trimble.com/environment/summary.html
Recycling in Europe
© 2012, Trimble Navigation Limited. All rights reserved.
Reorder PN 1213-1120 Rev A (04/12)
N324