Spectra QM55 User Manual

www.trimble.com/spectra
QM55 Quick Measure
Distance Meter
User Guide
Thank you for choosing the Spectra Precision QM55 from the Trimble family of precision products. This easy-to-use distance measuring tool will allow you to measure distances quickly, accurately and reliably.
Before using the Quick Measure, read this operator’s manual carefully. Included is information about operation, safety and maintenance.
Ensure that the operating instructions are with the laser distance meter when it is given to other persons.
Your comments and suggestions are welcome; please contact us at: Trimble Spectra Precision Division
8261 State Route 235 Dayton, Ohio 45424 USA Phone: +1 (937) 203-4419 +1 (800) 527-3771 Fax: +1 (937) 482-0030 Internet: www.trimble.com/spectra
– 2 –
Features
Protective overmolding
LiquidCrystalDisplay (LCD)
Power ON / Measure
Add next measure
Functions (area, volume, height)
Measure reference
Included with the QM55: Pouch, unit, battery, user guide, battery key/extension
– 3 – – 4 –
Subtract next measure
Units of measure / backlight
Clear previous reading / OFF
Batteries - Installation
1. Open the battery compartment using the supplied battery key or a coin.
2. Remove the batteries from the packaging and insert them in the tool.
NOTE
When installing batteries note the positive (+) and
negative (-) markings on the housings
3. Close the battery compartment cover.
Battery disposal - Some areas have regulations regarding the disposal of batteries. Be sure to dispose of discharged batteries properly.
CAUTION: The batteries should be removed when storing the laser more than 30 days.
Quick Start Guide
Unit OFF Press Press Time Press 2 Press Time Press 3 Press Time Comment
Power ON
Unit ON
Single measure
Continuous measure
Change measure reference
Turn on/off backlight
Area Short Cycle function to: Measure as shown Result shows 2 measures and area
Volume
Long
Short Short 1 turn on laser
2 measure
Long Short to stop Lastscreenshows Maximum distance
Minimum distance
Lastdistance
Short
Measure
from back
with
extension
Short
Short Cycle function to: Measure as shown Result shows 3 measures and volume
Measure from
front
Measure
from
center
Measure from
back
Measure from back is the default setting when turned on.
Features - LCD Detail
– 7 –
3rd prior measure
2nd prior measure
Previous measure
Current measure
Features - LCD Detail
Icon Name Description
Laseron Shows that laser is activated
Measure reference
Functions Indicates functions: area, volume, indirect measure
Continuous Measure
Signal strength indicator
Battery indicator
Data storage Indicates historical reading being displayed. 50 is
Hardware error
Indicates measure reference from front, center, back, and back with extended key
Symbol flashes when in continuous measure mode
More bars indicate strong signal, faster and more accurate measure. No bars indicate weak signal - best to adjust conditions
More bars indicate more battery power remaining Flashing indicates it is time to change batteries
most recent. 1 is the oldest
Switch unit on/off several time. If this symbol remains, contact your dealer
– 8 –
Indirect single height Short Cycle function to: Measure as shown Result shows 2 measures and distance
Indirect double height Short Cycle function to: Measure as shown Result shows 3 measures and distance
Stake Out Short Cycle function to: Use + to select
Addition Short Adds next measure
Subtraction
Units of measure change
Memory Short First clear screen measures Press + or- to cycle through measures.
Clear previous action
Power off Long
Short Subtracts next measure
Long m, ft, in, ft-in Cycle through units with long presses
Short Erase previous action
– 9 –
digit. Use - to change digits
Continuous measure; Beeps faster when near set value.
– 10 – – 11 – – 12 –
General Operation
Single distance measurement
1) Switch on the device by pressing the ON button.
2) Press the ON button again to activate the laser.
3) Aim the laser do to the surface to be measured, and press the On button again. The measurement will be shown in the display
4) Press and hold the OFF Button to switch off.
Continuous measurement
1) With the device on, press and hold the ON Button for 2 seconds until the continuous measure icon appears to activate continuous measuring mode. The tool beeps during continuous measure mode if beeper is turned on.
2) Press the Measure Button again to stop continuous measure. When continuous measure is stopped, the display will show:
• Maximumdistance
• Minimumdistance
• Lastdistance
Continuous measure can be useful to find the shortest distance to a wall or longest distance to a corner as shown.
Clear button
Press the C/OFF button to clear the last reading or command. During area and volume measures, the C/OFF button clears the most recent measure, but preserves previous measures.
Change reference
Default measure reference is the back of the unit. Press the MEASURE REFERENCE button to change to front, center or extended back with tail as shown on the icon.
Display backlight
PresstheUNIT/LIGHTbuttontoturnthebacklightonoroff.
Setting unit of measure
PressandholdUNIT/LIGHTbuttonuntiltheunitsofmeasure
changes. Press again to change to next unit of measure. Unit of measure options are: m, ft, in, ft-in.
FUNCTIONS - Area, Volume, Indirect Measure (Pythagorean Theorem)
1) Press the FUNC button and cycle through the symbols until you arrive at the desired function as shown in this figure.
Area Volume Indirect Double Indirect
2) Press the ON button to activate the laser and take first measure
3) Press the ON button to activate the laser and take second measure
4) Press the ON button to activate the laser and take third measure (if required)
The display will indicate which measure is being taken as per the following chart.
– 13 – – 14 – – 15 – – 16 –
FUNCTIONS - Area, Volume, Indirect Measure
Measurement Function Icons Measurement Sequence
Single Measurement
Area Measurement
Volume Measurement
Height (Pythagorean Theorem)
Measurement 1
Height (Pythagorean Theorem)
Measurement 2
The result will be displayed along with the individual measures. NOTE: The indirect and indirect double measurements are based
upon the Pythagorean principle which requires a right angle (90⁰) for accuracy. The indirect measure estimate is less accurate if the measurements do not form a right angle.
Addition and Subtraction
+ The next measure is added to the previous one
- The next measure is subtracted from the previous one See figure
Storage and Recall of Measurements
The QM55 will automatically store the previous 50 measurements results.
1) To retrieve these measures: press the clear button (C/OFF)until there are no measures shown on the screen
2) Press the + button. The Display will appear like the figure.
3) The higher number (up to 50) indicates the most recent measurement taken.
4) Use the + or – buttons to scroll through the measurements.
Specifications
Measuring Range 0.5 m to 50 m (1.6 to 165 ft)
Accuracy ± 1.5 mm typical (± 1/16 in)
Functions Measure, Continuous measure, Area, Volume,
Measure reference Front, Center, Rear, Rear with Extension
Automatic shut o Laser-0.5minutes
Battery life (alkaline) 5000+ measures
Operating temperature -10⁰C to +50⁰C (14⁰F to 122⁰F)
Storage temperature -20⁰C to +65⁰C (-4⁰F to 149⁰F)
Power supply 2 x AAA x 1.5V
Power indication LCD3segments-100%,50%,0%
LaserSafety Class II as per EN 60825-1:2007;
LaserType/Power 635 nm visible red / 0.95 mW max
Dimensions 52 x 28 x 125 mm (2.0 x 1.1 x 4.9 in)
Weight 180 g (6.35 oz) without batteries
Dust & Water resistance IP54
Drop Performance 1.5 m (5 ft)
Pythagorean, Add/Subtract, Stake out, memory 50 measures
Product - 3 minutes
IEC 60825-1:2007 CFR 21 § 1040 (FDA)
General Care, Safety And Storage
General safety rules
a) Check the condition of the tool before use. b) The user must check the accuracy of the tool after it has been
dropped or subjected to other mechanical stresses. c) Although the tool is designed for the tough conditions of jobsite use,
as with other measuring instruments it should be treated with care.
Do not use prisms or mirrored surfaces
Distances can be measured from all stationary targets without a highly reflective surface, i.e. concrete, stone, wood, plastic, paper, etc. The use of prisms or other highly reflective targets is not permissible and, if attempted, may falsify the results.
Calibration Check
It is recommended to occasionally check the calibration of the tool.
1) Select a known measure distance about 1 to 5 meters (3 to 15 ft) that does not change over time.
2.) Measure the distance 10 times. Calculate the mean deviation from the actual distance. The measured mean deviation should be less than the typical accuracy tolerance of
± 1.5 mm (± 1/16 in)
– 17 – – 18 – – 19 – – 20 –
Cleaning and drying
1. Blow dust off the lens.
2. Do not touch the lens with the fingers.
3. Use only a clean, soft cloth for cleaning. If necessary, moisten the cloth slightly with pure alcohol or a little water.
NOTE
Do not use any other liquids as these may damage the plastic
components.
Storage
The temperature limits for storage of your equipment must be observed, especially in winter / summer.
Remove the tool from its pouch if it has become wet. The tool, its carrying case and accessories should be cleaned and dried (at maximum 40°C). Repack the equipment only once it is completely dry. Check the accuracy of the equipment before it is used after a long period of storage or transportation.
Transport
Use the original packaging or packaging of equivalent quality for transporting or shipping your equipment.
CAUTION
Always remove the batteries before shipping the tool.
Trouble Shooting
Message Code Possible cause Remedy
101 Battery too low Change batteries
104 Calculation error Repeat procedure
152 Temperature too high Allow the unit to cool down
153 Temperature too low Allow the unit to warm up
154 Out of range Measure target within distance of 0.5 and 50 m (1 to 165 ft)
155 Received signal too weak Use light color target;
Hold Quick Measure more steady
156 Received signal too strong Use dark colored target
157 Background brightness too high Use dark-colored target
Weak signal Adjust measurement conditions until signal strength is stronger
Hardware error Switch unit on/off several time. If this symbol remains, contact your dealer
Laser Safety
Use of this product by people other than those trained on this product may result in exposure to hazardous laser light.
•Donotremovewarninglabelsfromtheunit.
•TheQM55isaClass2M(635nm)laserproduct.
•Neverlookintothelaserbeamordirectittotheeyesofotherpeople.
•Alwaysoperatetheunitinawaythatpreventsthebeamfromgetting
into people‘s eyes.
– 21 – – 22 – – 23 –
Warranty
Trimble warrants the Quick Measure QM55 to be free of defects in material and workmanship for a period of 3 years. For the first 2 years, Trimble or its authorized Dealer or Service Center will repair or replace, at its option, any defective part, or the entire product, for which notice has been given during the warranty period. For the 3rd year, an exchange fee may apply. This warranty period is in effect from the date the system is delivered by Trimble or its authorized Dealer to the purchaser, or is put into service by a Dealer as a demonstrator or rental component.
Any evidence of negligent or abnormal use, or any attempt to repair equipment by other than factory-authorized personnel or Trimble certified or recommended parts, automatically voids the warranty.
The foregoing states the entire liability of Trimble regarding the purchase and use of its equipment. Trimble will not be held responsible for any consequential loss or damage of any kind.
This warranty is in lieu of all other warranties, except as set forth above, including an implied warranty. Merchantability of fitness for a particular purpose is hereby disclaimed.
Customers should send products to the nearest authorized Factory, Dealer or Service Center for warranty repairs, freight prepaid. In countries with Trimble Service Subsidiary Centers, the repaired products will be returned to the customer, freight prepaid.
Service Request
To locate your local dealer or authorized Trimble Service Center outside the U.S.A. for service, accessories, or spare parts, contact one of our offices listed below.
North-Latin America
Trimble / Spectra Precision Division
8261 State Route 235
Dayton, Ohio 45424-6383
U.S.A.
(888) 527-3771
(Toll Free in U.S.A.)
+1-937-203-4419 Phone
+1-937-482-0030 Fax
www.trimble.com/spectra
Europe
TrimbleKaiserslauternGmbH
Am Sportplatz 5
67661 Kaiserslautern
GERMANY
Tel +49-(0)6301-71 14 14
Fax +49-06301-32213
Africa & Middle East
Trimble Export Middle-East
P.O. Box 17760
JAFZ View, Dubai
UAE
+971-4-881-3005 Phone
+971-4-881-3007 Fax
TrimbleNavigationSingaporePTELtd.
Asia-Pacific
80 Marine Parade Road, #22-06
Parkway Parade
Singapore, 449269
+65 6348 2212 Phone
+65 6348 2232 Fax
China
Trimble Beijing
Room 2805-07, Tengda Plaza,
No. 168 Xiwai Street
Haidian District
Beijing, China 100044
+86 10 8857 7575 Phone
+86 10 8857 7161 Fax
www.trimble.com.cn
Declarations
We declare, on our sole responsibility, that this product complies with the following directives and standards:
EN 50081-1, EN 61000-6-2, 2004/108/EC.
Designation:Laserrangemeter
Type: QM55
Notice to Our European Union Customers
For product recycling instructions and more information, please go to: www
To recycle Trimble WEEE, call: +31 497 53 2430, and ask for the “WEEE
associate,” or
mail a request for recycling instructions to:
Trimble Europe BV c/o Menlo Worldwide Logistics Meerheide 45 5521 DZ Eersel, NL
.trimble.com/environment/summary.html
Recycling in Europe
© 2012, Trimble Navigation Limited. All rights reserved.
Reorder PN 1213-1320 Rev A (08/12)
N324