O2PTZ22D5W(Outdoor), O2PTZ34D5W(Indoor), is a state-of-the-art Speed Dome Network Camera based on
integrated Embedded Software technologies such as H.264 & MJPEG, G.726 & PCM Video & Audio
Compression, Embedded Web Server, Embedded Streaming Server, various Network Protocols, transmits
synchronized video and audio data in real time through IP Network as well as supports bi-directional audio
communication by allowing transmission of audio from Client PC to the camera
O2PTZ22D5W, O2PTZ34D5W is applicable for various sectors such as Security, Remote Monitoring, Remote
Education, Simple Video Conference as well as Internet Broadcasting System etc.
AC adapter which is compliant to the specification for the camera should be used. Misuse of
power supply can cause damage to the unit. Speco assumes no responsibility for misuse of the
power supply.
Red/Green LED will be lit with red momentarily and it will be lit with green after a while when
power is applied to the camera.
DC Power
Connect 12 Volt DC adapter to this terminal for supplying power to the network camera.
MIC/LINE IN
Connect external audio source or microphone.
Line Out
Connect speakers with built in amplifier. Audio from remote site is output through Line out in bi-directional
audio mode.
100Base-T
100Mbps Ethernet connector (RJ-45). 2 LEDs on the Ethernet connector show the status of the camera
as the following:
- Status LED (Dual Color - Red/Green): It will be lit in green or red depending on the status. Green: Green color indicates that the camera is in normal operation mode. Continuous green
indicates that data transmission is possible. Blinking green means that someone is
connected to the camera
Red: Continuous or blinking red indicates that hardware is in abnormal condition.
LINK/LAN LED (Orange): It will be lit with orange color when the network cable is connected properly.
Blinking orange color indicates that normal data transmission is under way. Off state indicates that there
is trouble with the network connection.
Used for connecting power cable of heater and fan. Power cable of heater and fan is in the bracket.
Alarm In/Out (ALARM/AUX)
Used for connecting alarm sensor, alarm annunciation device.
Aux
Relay output is provided for connecting alarm devices or for remote on/off control of devices such as light.
Relay is normal open and it will be closed upon alarm annunciation or remote on.
Fig 2-5. Relay Connection Diagram (Left: lower than 24V, 1A, Right: Higher than 24V 1A)
Alarm
Connect external alarm sensor. Examples of sensing devices are infrared sensor, motion sensor,
heat/smoke sensor, magnetic sensor, etc. Connect the two wires of the sensors to “SNS In”. The sensor
type (NC/NO) can be set in admin page. Multiple sensor devices can be connected in parallel.
The wall should be strong enough to hold 4 times of the weight of the camera (5.3 KG). This means that the
wall should withstand weight of 21.2 KGs in the minimum.
1. Pass the combined cable through the inside Cable Gland.
2. Fix the end of Cable Gland on the bottom case and coat the attached line between top & bottom
of Cable Gland bottom case with silicone. For the installation at Bottom of Bracket, Gland Cable
Installation is not required (refer to the below Fig).
2. Connect PC and O2PTZ22D5W, O2PTZ34D5W to Network Device (HUB)
I. Prepare a PC which needs to be connected to Network.
II. Connect PC with Product as in Fig 4-1.
3. Install Speco-NVR
Speco-NVR is a multi-channel VMS program for to IP camera or Video server. Install Speco-NVR on remote PC
to connect to these products. It is needed to assign connection information to Speco-NVR program before
connection.
Insert the CD provided with product into the PC and install the Speco-NVR.
Follow the sequence below for setting the IP parameter
i) Run IP installer
ii) Click (1) in ONSIP installer window.> Double click on (2) > Fill in (4) > make a selection in (5) > Fill the
parameters in (6)
iii) Click on (9) to apply the settings.
iv) You can connect to admin page by clicking on (10).
Click on the field in (3) for sorting and rearranging the list.
Select network mode that best suits from the drop down list in (5). You can choose either
Static or ADSL and Auto (DHCP), respectively. If ADSL and Auto are selected, the fields in (6)
are deactivated.
In case of ADSL, fill the User Name and Password in (8) with the values provided by your ISP.
If DDNS service is needed, Check at the box and fill the empty field with hostname you want in
For the use of Web Viewer, Active-X module should be installed.
If internet access is available, you can download it by accessing Camera or if you install
Speco-NVR, Active-X module will be installed together.
Connection to Admin Page
Basic Control Buttons
Video Crop Control
4. Remote Connection to Camera
I. Connection via Web Viewer
Web View is the simplest method to connect to the product via internet explorer. Once you
insert ”http://IP_address:HTTP_port_number” into Internet Explorer, you can access the page.
Fig 4-3. Web Viewer Connection
Basic ID / Password of Admin Tool: admin /1234
For the detail, please refer to [Configuration_Guide].
1) Connection through Speco-NVR
Click the camera assignment button for setting camera address. Input the description, address, Ch#,
User ID, Password and port and then click the save button. After assignment procedure, you must
click the SAVE button. You can see the live video when you click the live view button as below. When
you exit Speco-NVR, you have to input the ID/PW, admin/1234. Details for the Speco-NVR can be
found in [Speco-NVR User’s Guide].
All Parameters of O2PTZ22D5W are initially set as factory default. So you must change them with appropriate
value to your network configuration by accessing via Admin Tool. Admin Tool Access Method is as below.
Http://[IP Address]:[HTTP Port No.]/ admin.htm
Admin Tool Access ID / Password: admin / 1234. As it is Default Value, please change them. For the detailed
Configuration, please refer to [Configuration_Guide].