Speco HTSD12X User Manual

HTSD12X
12X Optical Zoom
Indoor / Outdoor Speed Dome Camera
Please read this manual thoroughly before operation and keep it handy for further reference.
CONTENTS
CONTENTS
CONTENTSCONTENTS
Warning & Caution
What’s in the Box?
General Features
3
3
4
Overview of Parts
Installation
A. Connection Methods
B. Ceiling Mount Type
C. Embedded Mount Type
Quick Operation Keys
Diagnostic
OSD Menu Setting
A. OSD Menu Table
B. DOME SET
C. CAMERA SET
D. PRESET
E. AUTO SCAN
F. TOUR SET
G. PRIVACY SET
H. PATTERN SET
I. ALARM SET
J. SECTOR SET
DIP Switch Setting
A. ID Setting (DIP SW1)
B. Protocol/ Baud Rate Setting (DIP SW1-9~10)
Trouble Shooting
5
6
7
8
9
10
11
16
18
19
20
21
22
23
24
25
26
27
Specification
Dimension
2
28
29
WARNING
WARNINGWARNING
WARNING
&&&&
CAUTION
CAUTIONCAUTION
CAUTION
user to
insulated “dangerous
voltage” within the product’s enclosure that
may be of sufficient magnitude to
electric shock to
This symbol is intended to alert the user to
important operating and
maintenance (servicing) instructions in the
If you fail to read this information and
handle the product incorrectly, death or
serious injury may occur.
The unit should be installed by a trained
professional
Immediately stop usage when the product
emits smoke or abnormal heat.
Never install the product in an area exposed
to water, oil or gas.
Never install the product on a ceiling that
cannot hold its weight.
Never touch the power cord with wet hands.
Clean only with dry cloth.
Never install the product in extreme high or
low temperature.
Never drop, hit strongly, or vibrate the
product.
Never expose the product to direct sunlight
or severe ray.
Never touch the front glass of the product.
Never install the product in areas exposed to
rain or water
This symbol is intended to alert the the presence of un-
constitute a risk of persons.
the presence of
literature accompanying the appliance.
Warning
Never operate Pan/Tilt with hands. It may
cause serious damage to the camera.
What’s in the Box ?
1. Camera
2. Screws ( Ø4x16 screw 5EA )
3. Terminal block (6pin 1EA,5pin 1EA)
4. Manual
5. Screw Cap (2 EA)
3
GENERAL FEATURES
GENERAL FEATURESGENERAL FEATURES
GENERAL FEATURES
changeable Day/Night (ICR block filter) function and DSS.
144X Zoom Mini Speed Dome
12X Optical Zoom with 12X digital zoom
±±±±
0.02
°°°°
dome system accuracy with 1/4
micro step
With 0.1° technical accuracy, camera provides excellent sensitive and delicate controlling on preset mode by adapting 1/4 micro step and twin gear system
360° Endless Rotation
12X mini speed dome is capable of endless rotation of 360 degrees
Compensation function: preset position
The function minimizes the appearance of shaky images caused by low-frequency vibration, wind and any impact and maintains a normal horizontal resolution. Sets the starting point of pan/tilt on preset mode by using joystick turning one time without turning off the power of the camera. It is useful for outdoor surveillance and traffic monitoring applications.
Over 240
The 360° full pan function moves at a maximum of 240°/sec., enabling you to quickly pinpoint the spot you want to watch. Tilt speed is a maximum 240°/sec on preset.
Polarity Protection of Power
This protection function prevents the power board from being damaged when the power source connects to an incorrect power terminal.
Filter changeable True Day/Night
Surveillance with optimum picture is possible owing to filter
The auto IR cut filter removable function controls operation such as color picture plus infrared cut filter during the day and black and white picture plus filter elimination at night.
Indoor / Outdoor applications
Compact and minimal dome size allows for various install applications
°°°°
/Sec Preset Speed
Quick Operation Keys
This camera provides quick functional keys to be easily controllable by another controller or DVR.
Various Surveillance Functions
Auto Scan
positions with different speed and dwell time.
8 Group Tour
available and each group is consisting up to 60 presets step with different speed and dwell time with 16 characters.
164 Preset positions
preset positions are available with 16 characters
8 Patterns
patterns are available with 16 characters and each one consists of 50 seconds, up to total 400 seconds.
8 Sectors
are available with 16 characters
4 Privacy Masking Zones
user-defined privacy masking zones are available with 16 characters
4 Alarm input
preset, tours, patterns.
240
This camera provides up to 240°/sec of manual speed and is adjustable from 1°/sec to 240°/sec at an interval of 10°/sec
repeats pan and tilt between two preset
up to 8 Programmable Group tours
up to 164 programmable
up to 8 programmable user-defined
up to 8 programmable user-defined sectors
up to 4 programmable
up to 4 alarms can be activated with
°°°°
/S – Manual speed
1/4” Sony Super-HAD CCD
Equipped with Sony Super-HAD CCD technology, this camera provides excellent sensitivity and low smear levels.
Intelligent Pan/Tilt Controlling
Intelligent Pan/Tilt function decreases pan and tilt speeds in proportion to zoom.
Aluminum case and PC cover
Aluminum body and Poly Carbonate dome (IP66 Rated) .
Password Protection
4
OVERVIEW OF PARTS
OVERVIEW OF PARTSOVERVIEW OF PARTS
OVERVIEW OF PARTS
1. Surface Mount Adaptor
2. Cap Screw ( PT3/4 , 2EA )
3. Dip Switch
4. Terminal Block
5. Main body
5
INSTALLATION
INSTALLATIONINSTALLATION
INSTALLATION
A. CONNECTION METHOD
A-1
1. Loosen the screws on the dome cover and remove it from the base. (Screws will not fall out)
2. Loosen the screws which connect mount cover and Main base and separate dome cover from the main base. (Screws will not fall out)
3. Connect power (12VDC or 24VAC)
4. Connect video to Video and GND.
5. Connect communication cable to RS-485 connectors.
6. Connect alarm cable to GND like 1 and GND, 2 and GND, 3 and GND, 4 and GND.
(You can use both N.O / N.C methods.)
Don’t screw too tightly. It can be the cause of a defect.
6
INSTALLATION
INSTALLATIONINSTALLATION
INSTALLATION
B. MOUNT
1. Fix the surface mount adaptor with 4pcs of screws on the place where you want to
2. When you use pipe, please note the standard size of pipe. (FIG.5)
3. Re-assemble the domes.
install. (FIG.4)
7
QQQQUICK OPERAT
UICK OPERATION
UICK OPERATUICK OPERAT
1-64 + preset and 101~200 + preset are used for preset and 65-100 + preset used for functions.
For example, to enter OSD MENU, press the button 95 + PRESET or 95 +ENTER
<Quick Operation Key Table 1, Pelco - D, P>
Number Note Function
1 ~ 64, 101~200 +Preset PRESET Executing Preset 1 ~ 64 65 + Preset PRESET STATUS Display Preset Status 66 +Preset AUTO SCAN Executing Auto Scan 67 +Preset AUTO FLIP Selectable On/Off/Auto in Auto Flip function 71~78 +Preset GROUP TOUR Executing Group Tour #1 ~ #8 81~88 +Preset PATTERN Executing Pattern #1 ~ #8 91 + Preset ZERO POSITION 92 + Preset FREEZE 93 + Preset BLC MODE Selectable On/Off in BLC function 94 + Preset D/N MODE Selectable Day/Night Mode (Auto/Day/Night Mode) 95 + Preset OSD MAIN MENU To enter OSD Main Menu 96 + Preset FOCUS ADJUST Focus adjusting 97 +Preset ALARM Selectable Enable/Disable all Alarms
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
Menu Function
Tilt Up / Down Sub menu cursor moves up / down Pan Left / Right Enter to the sub menu or status change or decrement Focus Near Using for Enter key when user select YES or NO Focus Far Using for function changing keys when set coordinate Zoom Tele Status cursor to the right Zoom Wide Status cursor to the left
* 65 + preset: Status Report, if user presses ‘Near’ key, it disappears.
ION KEYS
IONION
KEYS
KEYSKEYS
8
QQQQUICK OPERAT
UICK OPERATION
UICK OPERATUICK OPERAT
DIAGNOSTIC
DIAGNOSTIC
DIAGNOSTICDIAGNOSTIC
When Power is on, DIAGONOSTIC is operational.
The following messages are displayed on the monitor.
CAMERA ID : 001
BAUD RATE : 2400 BPS
WAITING………
ION KEYS
IONION
KEYS
KEYS KEYS
PAN ORIGIN CHECK OK
TILT ORIGIN CHECK OK
TX CONNECTION TEST OK
CAMERA COMM TEST OK
A.
Pan Origin Test
Zero point of Pan is found after Panning test.
B.
Tilt
Origin Test
Zero point of Tilt is found after Tilting test.
C
.
TX connection Test
Countdown from 60 seconds for TX Connection Test,
During 60 seconds, the camera must receive a signal from any key of the controller or DVR.
When received the correct signal, OK is displayed after TX CONNECTION TEST.
* If “No Tested” is displayed on the monitor,
- Camera did not receive the any signal.
- Camera did receive the signal but did not correct it.
- User should check protocol, baud rate and RS-485 connection.
D.
Camera Comm. Test
Communication test with the camera is automatically checked.
OK should be displayed in these four tests before installation.
If all the above Tests are OK, “NOW EEPROM CHECKING” and “EEPROM OK” is displayed and the
camera is ready to operate.
9
10
EXIT
[REVIOUS PAGE]
[PREVIO
U
S PAGE]
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
A. OSD MENU TABLE
AUTO SCAN SET
START ANGLE : XXX.X.XX .X
END ANGLE : XXX.X.XX.X
DIRECTION : CW
ENDLESS : OFF/ON
SPEED : 10
PRESET SET
PRESET NO: 001
PRESET ID: PRESET01□□□□□□□ □□
SAVE
EXIT
PAN:XXX.X.XX.X TILT:XX X.X.XX.X
CAMERA SET
FLICKER : OFF/ON
MIRROR : OFF/ON
APERTURE : 02
D ZOOM : OFF/ON
WB MODE : ATW2 MODE
/S
°
DOME SET
RECOVER : OFF
CAMERA ID : CAM1□□□□□□□□□□□ □
SPEED : FAST
MANUAL SPEED : 100
AUTO FLIP : OFF
ZOOM
MAIN MENU
DOME SETUP
CAMERA SET
PRESET
AUTO SCAN
DWELL TIME : 03
SAVE AND EXIT
EXIT
PIC FLIP : OFF/ON
BLC : OFF/ON
D/N MODE : AUTO MODE
DSS MODE : OFF/ON
EXIT
ALARM : DISABLE
LANGUAGE : ENGLISH
TOUR
PRAVACY
EXIT
[NEXT PAGE]
SAVE AND EXIT
PATTERN
ALARM
SECTOR
SECTOR SET
SECTOR NO : 01
SECTOR ID : SECTOR01□□□
SECTOR START: XXX.X.XX .X
SECTOR END : XXX.X.XX.X
SAVE
EXIT
ALARM SET
ALARM NO. : 01
ALARM INPUT : OFF
PATTERN SET
PATT NO. : 01
PATT TITLE PATTERN01□□□
PRIVACY SET
PRIVACY NO. : 01
DISPLAY : OFF
TOUR SET
TOUR NO. : 01
TOUR TITLE : TOUR01□□□□□□
ALARM ACT : 001
SAVE
EXIT
DATA FILL : 000%
SAVE
EXIT
ACTION : MOVE
SAVE
EXIT
/S
°
EXIT
TOUR STEP : 01
PRESET NO : BLK
SAVE AND EXIT
DWELL TIME : 03
SPEED : 200
[INITIALIZATION]
[TOUR CLEAR]
[PRESET CLEAR]
[SECTOR CLEAR]
[PRIVACY CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAUL T
[SYSTEM STATUS]
PROTOCOL : PELCO D,P
BAUD RATE: 2400BPS
FIRMWARE VER.:3.00
UPGRADED DATE: 12.08.1 0
CAMERA MODULE:SCC-ZM12 3
VIDEO TYPE : NTSC
OSD DISPLAY
CAMERA ID: OFF/ON
PRESET ID: OFF/ON
SECTOR ID: OFF ON
COORDINATE:ON/OFF
[PREVIOUS PAGE]
PASSWORD
ENTER PASSWORD
BY ENTERING PRESET COD E
PASSWORD ***
CONFIRM ***
NEXT PAGE
SYSTEM LOCK : OFF/ON
[PASS WORD ]
[OSD DISPLY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
11
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
To enter OSD Menu, press the button 95 + PRESET.
MAIN MENU
DOME SETUP PRESET CAMERA SET AUTO SCAN TOUR PRIVACY PATTERN ALARM SECTOR EXIT
*Move the joystick up / down to highlight the selection and left / right to make the selection
B. Dome Setup
To enter Dome setup, move the joystick to the right when the setting is highlighted
DOME SET
CAMERA ID : CAM1□□□□□□□□□□□□ RECOVER : OFF MANUAL SPEED : 100°/S
AUTO FLIP : OFF ZOOM SPEED : FAST ALARM : DISABLE LANGUAGE : ENGLISH [NEXT PAGE] SAVE AND EXIT EXIT
DEFAULT SETTING
B-1.
To set camera ID, select up to 16 characters using Joystick to the left or right.
DOME SET - CAMERA ID
Press ZOOM TELE button to move to the next character from left to right direction and
ZOOM WIDE button to move to the next character from right to left direction
(Space displays when appears)
12
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
B-2.
B-3.
B-4.
B-5.
DOME SET - RECOVER
This feature allows the dome to recover to the last setting before the dome was used manually
(Auto scan, group tour, pattern or sectors), after the set time, power will shut down and turn back
on. Recover time can be programmed from 15 second to 90 seconds. The default setting is
OFF.
DOME SET - MANUAL SPEED
Manual Speed of Pan/Tilt is selectable from 1°/sec up to 240°/sec.
The default setting is 100°/sec
DOME SET - AUTO FLIP
Auto Flip is available and the default setting is OFF. Move joystick “right or left” to select ON or
OFF. The default setting is OFF. This function can be recalled by pushing 67+ preset button.
DOME SET – ZOOM SPEED
Zoom speeds are selectable FAST or SLOW mode. Move joystick to the right direction for
selecting FAST or SLOW. The default setting is FAST.
B-6.
DOME SET – ALARM
All alarms are available after set as ENABLE Mode. Move joystick to right or left direction for
selecting ENABLE/DISABLE. The default setting is DISABLE. This function can be recalled by
pushing 97 + preset button.
B-7.
DOME SET - LANGUAGE
Multiple languages are selectable here including English, Italian and Polish. Move joystick to the
right or left direction to select language. The default setting is ENGLISH.
B-8.
DOME SET – [NEXT PAGE]
DOME SET
SYSTEM LOCK: : OFF [PASS WORD] [OSD DISPLAY] [SYSTEM STATUS] [INITIALIZATION] [PREVIOUS PAGE]
B-8-1.
DOME SET – [NEXT PAGE] – SYSTEM LOCK
Password protection allows settings to be stored. One then must enter the correct password to
change the settings. In order to enter [PASS WORD] page, system lock status is must set as ON.
Move joystick to right or left direction to select ON. The default setting is OFF.
DEFAULT SETTING
13
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
B-8-2.
DOME SET – [NEXT PAGE] – [PASSWORD]
To enter this page to set a password, SYSTEM LOCK should be ‘ON’ then move joystick to the
right direction on [PASSWORD]. The password must be set by preset number from 001 to 255
(Default 99)
A. OSD MAIN MENU TABLE (PAGE 11) The default setting is BLANK.
ENTER PASSWORD
BY ENTERING PRESET CODE PASSWORD *** CONFIRM ***
Press any number from 001~255 with preset button on password blank and again it on confirm
blank. Then “CONFIRMED” is displayed on the monitor and the menu will go back to the previous
page automatically.
ENTER PASSWORD
BY ENTERING PRESET CODE PASSWORD *** CONFIRM ***CONFIRMED
ENTER PASSWORD
BY ENTERING PRESET CODE PASSWORD *** CONFIRM ***CANCELLED
B-8-3.
<CONFIRMED> <CANCELLED>
If user presses wrong preset number between PASSWORD and CONFIRM, “CANCELLED” is
displayed on the monitor and if user failed 3 times, the menu will return to the previous page
automatically * After setting a Password, an operator must enter the correct password in order to
enter OSD MAIN MENU, or to change the settings.
* An operator must remember the password for the operation. Manufacturer doesn’t provide
password recovery.
DOME SET – [NEXT PAGE] – [OSD DISPLAY]
OSD ID displayed after set ON in here and it can be hiding if selected OFF. Move joystick to the
right or left direction in order to select OFF/ON when the cursor is located each item.
14
[PREVIOUS PAGE]
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
OSD DISPLAY
CAMERA ID : OFF PRESET ID : OFF SECTOR ID : OFF COORDINATE : ON [PREVIOUS PAGE]
DEFAULT SETTING
B-8-4.
B-8-5.
DOME SET – [NEXT PAGE] – [SYSTEM STATUS]
This page shows the information of this camera.
PROTOCOL : PELCO D, P BAUD RATE : 2400 BPS FIRMWARE VER. : 3.00 UPGRADED DATE : 12.08.10 CAMERA MODULE : SCC-ZM123 VIDEO TYPE : NTSC/PAL
- Protocol and baud rate are shown according to the dip switch setting
(Refer to page 29, 30 and 31)
- Firmware version and upgraded date will be changed if upgraded.
- Below camera modules can be set as follows.
SCC-ZM123: SAMSUNG 12X ZOOM CAMERA MODULE.
SYSTEM STATUS
DOME SET – [NEXT PAGE] – [INITIALIZATION]
To clear all memorized data for tour, preset, sector, privacy or pattern, move joystick to the right
direction when the cursor is on [INITIALIZATION]
[TOUR CLEAR] [PRESET CLEAR] [SECTOR CLEAR] [PRIVACY CLEAR] [PATTERN CLEAR] [LOAD OPTIMIZED DEFAULT] [PREVIOUS PAGE]
INITIALIZATION
DEFAULT SETTING
15
OS D M
OS D MENU SETTING
OS D MOS D M
- To clear any stored setting, move joystick to the right direction when cursor is on each
item.
Press FOCUS NEAR button when the cursor is at YES in order to clear the setting. Then each
item such as tour, preset, sector, etc will flicker on the monitor for about 2~3 seconds. After this
process, the menu is returned to the previous page.
* [PRESET CLEAR], [SECTOR CLEAR], [PRIVACY CLEAR], [PATTERN CLEAR] are same as
[TOUR CLEAR].
ENU SETTING
ENU SETTINGENU SETTING
TOUR CLEAR
ARE YOU SURE? YES NO
LOAD OPTIMIZED DEFAULT
ARE YOU SURE? YES NO
TOUR CLEAR
ALL DATA INITIALIZING
- To clear all data and return to factory default, move joystick to the right direction when cursor is at
[LOAD OPTIMIZED DEFAULT] to enter the above page.
- Move joystick to the right or left direction in order to select YES, press FOCUS NEAR button.
- “ALL DATA INITIALIZING” will be displayed for 5~7 seconds and then the menu will be returned to
the previous page automatically.
B-9.
DOME SET – [NEXT PAGE] – SAVE AND EXIT
To save the settings and leave this page, move joystick to the right direction when cursor
is at SAVE AND EXIT.
B-10.
DOME SET – [NEXT PAGE] – EXIT
In order not to save any setting and leave the page, move joystick to the right direction
when cursor is at EXIT
16
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU S ETTING
C. CAMERA SET
FLICKER : OFF MIRROR : OFF APERTURE : 02 D ZOOM : OFF WB MODE : ATW2 MODE PIC FLIP : OFF BLC : OFF D/N MODE : AUTO MODE DSS MODE : OFF EXIT
C-1.
CAMERA SET - FLICKERLESS
Flickerless feature is selected between 50Hz and 60Hz. The default setting is OFF (NTSC: 60Hz /
PAL: 50Hz). Set flicker mode ON when power source is in discord with frequency. The default
setting is OFF
CAMERA SET
C-2.
CAMERA SET - MIRROR
This feature shows a mirror image. The default setting is OFF.
C-3.
CAMERA SET – APERTURE
Aperture enhances picture details by increasing gain of the camera and sharpens the edges in the
picture. The default setting is 02. (the aperture level is from 00 ~ 03)
C-4.
CAMERA SET – D ZOOM
Move joystick to the right direction in order to set as ON. The default setting is OFF.
C-5.
CAMERA SET – WB MODE
White balance functions have 4 modes according to the condition of exterior lighting.
It may change the mode option according to the lighting conditions as below.
The default setting is ATW2 mode
ATW1 Mode - 2,500°K to 9,500°K
ATW2 Mode - 2,000°K to 10,000°K
Indoor – up to 3,200°K
Outdoor – up to 5,600°K
17
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU S ETTING
C-6.
CAMERA SET – PIC FLIP
Flips the picture horizontally. Move joystick to the right or left direction to select OFF/ON. The
default setting is OFF.
C-7.
CAMERA SET – BLC (Back Light Compensation)
The default setting is OFF and BLC modes can be OFF/ON.
OFF – Backlight compensation is not activated.
ON – Back light compensation is activated.
This function can be recalled by pushing 93 + preset button.
C-8.
CAMERA SET – D/N MODE
ICR filter is changeable according to the lighting, AUTO – NIGHT MODE – DAY MODE.
The default setting is AUTO MODE. This function can be recalled by pushing 94 + preset button.
C-9.
CAMERA SET – DSS MODE (DIGITAL SLOW SHUTTER)
If DSS is turned on, digital slow shutter is working. The DSS will remain open to receive some more
lighting.
The default setting is OFF.
C-10.
CAMERA SET – EXIT
To leave this page, move joystick to the right.
18
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
D. PRESET SET
To enter PRESET SET, move joystick to the right direction.
PRESET NO :001 PRESET ID :PRESET001------­PAN :XXX.XX TILT : XXX.XX SAVE EXIT
D-1.
PRESET – PRESET NO.
D-2.
PRESET – PRESET ID
D-3.
PRESET – PAN: XXX.X TILT: XX.X
PRESET SET
Up to 164 numbers of preset positions are available. Move joystick to the right or left direction to
select preset no.
To set preset ID, select up to 16 characters using Joystick to the left or right.
Press ZOOM TELE button moves to the next character from the left to the right direction and
ZOOM WIDE button moves to the next character from the right to left direction
(Space displays when appears)
Press FOCUS FAR button in order to set preset position, then, use the joystick move the camera to
the position where memorized preset no. is needed. Then press FOCUS FAR button again after
setting a preset location.
DEFAULT SETTING
D-4.
PRESET – SAVE
Move joystick to the right when the cursor is at SAVE and then the cursor will be located on Preset
ID for the continuous preset No. setting.
D-5.
PRESET – EXIT
To leave this page, move joystick to the right.
19
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
E. AUTO SCAN SET
E-1.
* 66 + preset button is working as AUTO SCAN after setting.
AUTO SCAN SET
START ANGLE : XXX.X.XX.X END ANGLE : XXX.X.XX.X DIRECTION : CW ENDLES : OFF SPEED : 10°/S
DWELL TIME : 03 SAVE AND EXIT EXIT
AUTO SCAN – START ANGLE
To set start angle, press FOCUS FAR button then use the joystick to move the camera to the desired
starting angle. Press FOCUS FAR button again leave.
DEFAULT SETTING
E-2.
AUTO SCAN – END ANGLE
To set end angle, press FOCUS FAR button use the joystick to move the camera to the desired starting
angle. Press FOCUS FAR button again leave.
E-3.
AUTO SCAN – DIRECTION
Auto Scan directions are available with two direction as CW or CCW by joystick to the right or left
CW: Clock-wise direction (Default)
CCW: Counter Clock-Wise Direction.
E-4.
AUTO SCAN – ENDLESS
Auto Scan can use endless rotation, move joystick to the right direction in order to select ON.
Otherwise, the default setting is OFF.
E-5.
AUTO SCAN – SPEED
User can use auto scan speed from 01°/S up to 35°/S. The default setting is 10°/S.
E-6.
AUTO SCAN – DWELL TIME
To select dwell time, move joystick to the left or right direction in order to adjust dwell time. This can
be set from 1 second to 99 seconds. The default setting is 3 seconds.
E-7.
AUTO SCAN – SAVE AND EXIT
To save the settings leave this page, move joystick to the right when cursor is at SAVE
AND EXIT.
E-8.
AUTO SCAN – EXIT
To leave this page, move joystick to the right.
20
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
F. TOUR SET
8 Programmable tours can be set and each tour is available to set up to 60 preset steps. After setting
the data to the each tour group, 71~78 + preset buttons are working as group tour # 1~8
TOUR NO : 01 TOUR TITLE : TOUR01□□□□□□□□□□ TOUR STEP : 01 PRESET NO. : BLK DWELL TIME : 03 SPEED : 200°/S
SAVE EXIT
F-1.
TOUR SET – TOUR NO.
Max. 8 group tour no. set by the joystick are available.
TOUR SET
DEFAULT SETTING
F-2.
TOUR SET – TOUR TITLE
To set tour title, select up to 16 characters using Joystick to left or right.
Press ZOOM TELE button to move the next character from the left to the right direction and ZOOM
WIDE button to move the next character from the right to left direction (Space displays when
appears) Tour title is not displayed on the monitor, but only for the reference of user.
F-3.
TOUR SET – TOUR STEP
Each tour group consists of up to 60 preset steps with different dwell time and speed. It is possible
to match any preset # for each tour step.
F-4.
TOUR SET – PRESET NO.
The decided tour step #1~60, it is possible to select any preset no. up to 164. The default setting
is BLK
F-5.
TOUR SET – DWELL TIME
Dwell time can be set from 1 second to 99 seconds. The default setting is 3 seconds.
F-6.
TOUR SET – SPEED
Each tour step can be set with different tour speed up to 240°/S and it is selectable from 10°/S.
Move joystick to the right or left direction to select tour speed. The default setting is 200°/S.
F-7.
TOUR SET – SAVE
To save the settings and leave this page, move joystick to the right when cursor is at SAVE
F-8.
TOUR SET – EXIT
To escape this page, move joystick to the right direction
21
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
G. PRIVACY SET
4 Privacy masking zones are available to block out areas of security.
PRIVACY NUMBER : 01 DISPLAY : OFF ACTION : MOVE SAVE EXIT
G-1.
PRIVACY SET – PRIVACY NUMBER.
Up to 4 privacy masking zones are available.
PRIVACY SET
DEFAULT SETTING
G-2.
PRIVACY SET – DISPLAY.
Move joystick to the right or left direction to set ON in order to show the selectable block in the
center of the monitor. This block appears as a translucent square with blue color after set ON.
The default setting is OFF.
G-3.
PRIVACY SET – ACTION (MOVE / POINT)
To set the privacy area, press FOCUS FAR button when on MOVE MODE. Then use the joystick
to the user defined area in order to set blocking area. Then press FOCUS FAR button again to
leave MOVE MODE.
To adjust size of privacy area, move joystick to the right or left direction when the cursor is on
ACTION. After move mode is changed to POINT MODE, press FOCUS FAR button in order to
adjust the size of privacy area. The size of blocking area can be adjustable by using joystick up
down or left right. After adjusting size of blocking area, press FOCUS FAR button to leave escape
POINT mode.
POINT: You can change the masking size by using joystick to the left or right direction
MOVE: You can move the masking area by using joystick to the left or right direction (Default)
G-4.
PRIVACY SET – SAVE
After setting the privacy masking zone, to save the data, move joystick to the right when the cursor
is on SAVE. After saving the data, the cursor moves to PRIVACY NO.2 automatically to prepare the
next privacy masking zone.
G-5.
PRIVACY SET –EXIT
To escape this page, move joystick to the right direction
22
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
H. PATTERN SET
8 programmable patterns are available with 16 characters of title.
After setting the data to each pattern # 1~8, 81~88+ preset buttons are working as Pattern # 1~8.
PATT NO : 01 PATT TITLE: PATTERN01□□□□□□□ DATA FILL : 000% SAVE EXIT
H-1.
PATTERN SET –PATT NO.
Up to 8 programmable user-defined patterns set by the joystick are available.
PATTERN SET
DEFAULT SETTING
H-2.
PATTERN SET –PATT TITLE
To set PATTERN TITLE, select up to 16 characters using Joystick to the left or right.
Press ZOOM TELE button moves to the next character from the left to the right direction and
ZOOM WIDE button moves to the next character from the right to left direction (Space displays
when appears) Pattern title is not displayed on the monitor, but only for reference.
H-3.
PATTERN SET –DATA FILL
To fill the programming data, press FOCUS FAR button in order to start the data fill up. Filling data
is programmed according to the joystick movement. Press FOCUS FAR button again in order to
leave.
H-4.
PATTERN SET –SAVE
To save the setting, move joystick to the right when the cursor is on SAVE. Then the cursor moves
to the PATT NO.02 in order to prepare next pattern no.
H-5.
PATTERN SET –EXIT
To leave this page, move joystick to the right
23
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
I. ALARM SET
4 Alarm inputs are available and each alarm is activating to presets, group tours or patterns.
I-1.
ALARM SET – ALARM NO.
I-2.
ALARM SET – ALARM INPUT
ALARM NO : 01 ALARM INPUT: OFF ALARM ACT : 001 SAVE EXIT
Up to 4 alarms are selectable by using joystick to the right direction when cursor is on ALARM NO.
Input alarm ways provide two different ways as NC (Normal Close) or NO (Normal Close)
The default setting is OFF
ALARM SET
DEFAULT SETTING
I-3.
ALARM SET – ALARM ACT
Alarm activates various surveillance modes with Preset number up to 164, Group tour up
to 8, Pattern up to 8. Move joystick to the right or left direction to select any preset
number, group tour no. or pattern no.
I-4.
ALARM SET – SAVE
After setting the alarm input ways and activation, to save the data, move joystick to the right when
the cursor is on SAVE. After saving the data, the cursor moves to Alarm NO.2 automatically to
prepare the next alarm.
I-5.
ALARM SET –EXIT
To escape this page, move joystick to the right
* Before activating Alarm, user must set ALARM ENABLE at DOME SET – ALARM – ENABLE
(Refer to page 15)
24
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
J. SECTOR SET
Up to 8 programmable sectors are available with 16 characters.
This feature is useful to store certain locations such as parking zone, etc.
When the camera scans this area, it shows the stored value.
SECTOR NO : 01 SECTOR ID: SECTOR01□□□□□□□□ SECTOR START: XXX.X.XX.X SECTOR END : XXX.X.XX.X SAVE EXIT
J-1.
SECTOR SET – SECTOR NO.
SECTOR SET
DEFAULT SETTING
Up to 8 programmable sectors set by the joystick are available.
Start Position
End Position
J-2.
SECTOR SET – SECTOR ID
To set SECTOR ID, select up to 16 characters by using Joystick to the left or right.
Press ZOOM TELE button to move to the next character from the left to the right direction and
ZOOM WIDE button to move to the next character from the right to left direction (Space displays
when appears)
J-3.
SECTOR SET – SECTOR START
To set SECTOR START angle, press FOCUS FAR button then move joystick to the left or right
direction to set the position. Press FOCUS FAR button again to leave.
J-4.
SECTOR SET – SECTOR END
To set SECTOR END angle, press FOCUS FAR button then move joystick to the left or right
direction to set the position. Press FOCUS FAR button again to leave
J-5.
SECTOR SET – SAVE
After setting the SECTOR position, to save the data, move joystick to the right direction when the
cursor is on SAVE. After saving the data, the cursor moves to SECTOR NO.2 automatically to
prepare the next SECTOR.
J-6.
SECTOR SET –EXIT
To leave this page, move joystick to the right
K. EXIT
To leave the OSD Main Menu, move joystick to the right or left direction then this camera
is ready to operate.
25
Termination
Protocol
ID Set
Baud rate
DIP SWITCH SETTING
DIP SWITCH SETTING
DIP SWITCH SETTINGDIP SWITCH SETTING
A-1. DIP SW SETTING
Mini Speed Dome camera provides up to 63 camera ID and it’s an adjustable ID with 1st~6th of Dip switch.
Open the camera case to set ID using DIP SW1.
* Factory default: Camera ID = 1, PELCO-D
A-2. ID SETTING
DIP SW ID VALUE DIP SW ID VALUE DIP SW ID VALUE
100000XXXX 010000XXXX 110000XXXX 001000XXXX 101000XXXX 011000XXXX 111000XXXX 000100XXXX 100100XXXX 010100XXXX 110100XXXX 001100XXXX 101100XXXX 011100XXXX
111100XXXX 000010XXXX 100010XXXX 010010XXXX 110010XXXX 001010XXXX
101010XXXX 011010XXXX
(1-ON, 0-OFF) (110)
1 111010XXXX 2 000110XXXX 3 100110XXXX 4 010110XXXX 5 110110XXXX 6 001110XXXX 7 101110XXXX 8 011110XXXX
9 111110XXXX 10 000001XXXX 11 100001XXXX 12 010001XXXX 13 110001XXXX 14 001001XXXX 15 101001XXXX 16 011001XXXX 17 111001XXXX 18 000101XXXX 19 100101XXXX
20 21 110101XXXX
22
010101XXXX
001101XXXX
23 101101XXXX 24 011101XXXX 25 111101XXXX 26 100011XXXX 27 100011XXXX 28 010011XXXX 29 110011XXXX 30 001011XXXX 31 101011XXXX 32 011011XXXX 33 111011XXXX 34 000111XXXX 35 100111XXXX 36 010111XXXX 37 110111XXXX 38 001111XXXX 39 101111XXXX 40 011111XXXX 41 111111XXXX
42 43
44
45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
26
DIP SWITCH SETTING
DIP SWITCH SETTING
DIP SWITCH SETTINGDIP SWITCH SETTING
A-3. PROTOCOL
7th~8th dip switches are used for Protocol Setting.
Factory Default: Pelco-D or Pelco-P (Auto detection)
DIP SW1- 7 DIP SW1- 8
OFF OFF Pelco-D or Pelco-P
A-4. BAUD RATE SETTING
The 9th Dip Switch is used for BAUD RATE setting.
DIP SW can be changeable to 2400bps, 9600bps.
Factory Default: 2400bps.
DIP SW1 9th BAUD RATE
OFF 2400
ON 9600
.
A-5. 485 TERMINATIONS
10th Dip Switch is used for 100 termination.
Set on 10th Dip Switch only for the last looped camera from the controller.
Even in case of only one camera, set on 10th Dip Switch of the cameras.
27
cable is connected correctly.
If excessive light is seen on a screen, change the camera
TROUBLESHOOTING
TROUBLESHOOTINGTROUBLESHOOTING
TROUBLESHOOTING
If you have trouble in operating in your camera, refer to the following.
PROBLEM
Check if the power supply is DC12V or AC24V.
No operation
Check if RS-485 communication Check camera ID setting. Check the termination.
Check if all the cables are connected correctly.
No picture
Check if the monitor is adjusted correctly. Check if video signal line is cut.
Dark screen Adjust the monitor status.
Abnormal camera
Operation status
Check if voltage level is out of the specification. Check the termination.
Check if there is dust on the lens. Adjust the monitor status.
Screen not clear
angle or location. Adjust the lens focus again.
SOLUTION
28
SPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
PAN /TILT
FUNCTIONS
POWER
OTHERS
CAMERA MODULE
MODEL
Pan Rotation Angle 360˚ Endless
Pan Speed
Tilt Rotation Angle 0˚ ~ 90˚
Tilt Speed
System Accuracy 0.02˚
Presets
Group Tour
Auto scan Programmable Auto scan Pattern 8 Programmable Patterns (total 400 seconds) Privacy Zone 4 privacy zones Sector 8 selectable Sectors with 16 characters Password Protection Yes Alarm Input 4 alarms OFF/NC/NO (with various programmable states) Alarm Actions Activate preset, Group scanning or Patterns Auto Flip ON / OFF OSD Menu Multiple Languages on screen Communication RS-485 Protocol Pelco D/P Power Consumption 12VDC 800mA / 24VAC 400mA Power Supply 12VDC or 24VAC(Dual Voltage) Construction die-casting , Anti-vandal dome cover Dimensions 167.0φ (D) * 167.0mm(H) Weight 1.5 kg Motor Type Stepper Motor Micro Steps 1/4 Step Storage Temperature -40F~ 140F Operating Temperature -14F ~ 120F
Image Sensor 1/4" Sony Super-HAD CCD
Total Image Pixels
Number Of
Effective
Pixels
Horizontal/Vertical resolution
Lens
Day & Night (ICR) Auto/ Day/ Night
Min. Shooting Distance 0.2m(Wide)/0.8m(Tele)
Digital Slow Shutter 2/4//6/8/12/16/24/32/48/64/96/128/256/ OFF
Min. illumination (F1.6/Wide)
Luminance S/N Ratio More than 52dB
Video Output VBS:1.0Vp-p/75 Ohm
BLC ON / OFF
Flickerless ON / OFF WHITE BALANCE
Manual 1˚ ~ 240˚/sec Preset Max 240˚ /sec
Manual 1˚ ~ 240˚/sec Preset Max 240˚ /sec
164 positions with a 16-character label available for each position
Max. 8 Programmable group tours (each one consisting of up to 60 preset steps
NTSC 811(H) * 508(V)
PAL 795(H) * 596(V)
NTSC 768(H) * 494(V)
PAL 752(H) * 582(V)
More Than 560(Color) / 600(BW) TV Lines
Optical
Digital 12x (144x with optical)
Color mode Night mode
12x Optical Zoom(f=3.6 to 44.3mm,
0.008 Lux (50IRE, Sens x256)
0.0008 Lux (50IRE, Sens x256)
ATW1/ATW2/INDOOR/OUTDOOR
HTSD12X
with different speed steps
with different steps)
F1.6(Wide)/F2.0(Tele)
29
DIMENSIONS
DIMENSIONS
DIMENSIONSDIMENSIONS
30
31
32
Speco Technologies is constantly developing product improvements. We reserve the right to modify product design and specifications without notice and without incurring any obligation. (Rev. 130328)