Please read this manual thoroughly before operation and keep it handy for further reference.
CONTENTS
CONTENTS
CONTENTSCONTENTS
Warning & Caution
What’s in the Box?
General Features
3
3
4
Overview of Parts
Installation
A. Connection Methods
B. Ceiling Mount Type
C. Embedded Mount Type
Quick Operation Keys
Diagnostic
OSD Menu Setting
A. OSD Menu Table
B. DOME SET
C. CAMERA SET
D. PRESET
E. AUTO SCAN
F. TOUR SET
G. PRIVACY SET
H. PATTERN SET
I. ALARM SET
J. SECTOR SET
DIP Switch Setting
A. ID Setting (DIP SW1)
B. Protocol/ Baud Rate Setting (DIP SW1-9~10)
Trouble Shooting
5
6
7
8
9
10
11
16
18
19
20
21
22
23
24
25
26
27
Specification
Dimension
2
28
29
WARNING
WARNINGWARNING
WARNING
&&&&
CAUTION
CAUTIONCAUTION
CAUTION
user to
insulated “dangerous
voltage” within the product’s enclosure that
may be of sufficient magnitude to
electric shock to
This symbol is intended to alert the user to
important operating and
maintenance (servicing) instructions in the
If you fail to read this information and
handle the product incorrectly, death or
serious injury may occur.
The unit should be installed by a trained
professional
Immediately stopusage when the product
emits smoke or abnormal heat.
Never install the product in an area exposed
to water, oil or gas.
Never install the product on a ceiling that
cannot hold its weight.
Never touch the power cord with wet hands.
Clean only with dry cloth.
Never install the product in extreme high or
low temperature.
Never drop, hit strongly, or vibrate the
product.
Never expose the product to direct sunlight
or severe ray.
Never touch the front glass of the product.
Never install the product in areas exposed to
rain or water
This symbol is intended to alert the
the presence of un-
constitute a risk of
persons.
the presence of
literature accompanying the appliance.
Warning
Never operate Pan/Tilt with hands. It may
cause serious damage to the camera.
What’s in the Box ?
1. Camera
2. Screws ( Ø4x16 screw 5EA )
3. Terminal block (6pin 1EA,5pin 1EA)
4. Manual
5. Screw Cap (2 EA)
3
GENERAL FEATURES
GENERAL FEATURESGENERAL FEATURES
GENERAL FEATURES
changeable Day/Night (ICR block filter) function and DSS.
144X Zoom Mini Speed Dome
12X Optical Zoom with 12X digital zoom
±±±±
0.02
°°°°
dome system accuracy with 1/4
micro step
With 0.1° technical accuracy, camera provides excellent
sensitive and delicate controlling on preset mode by
adapting 1/4 micro step and twin gear system
360° Endless Rotation
12X mini speed dome is capable of endless rotation of 360
degrees
Compensation function: preset position
The function minimizes the appearance of shaky images
caused by low-frequency vibration, wind and any impact
and maintains a normal horizontal resolution. Sets the
starting point of pan/tilt on preset mode by using joystick
turning one time without turning off the power of the
camera. It is useful for outdoor surveillance and traffic
monitoring applications.
Over 240
The 360° full pan function moves at a maximum of
240°/sec., enabling you to quickly pinpoint the spot you
want to watch. Tilt speed is a maximum 240°/sec on
preset.
Polarity Protection of Power
This protection function prevents the power board from
being damaged when the power source connects to an
incorrect power terminal.
Filter changeable True Day/Night
Surveillance with optimum picture is possible owing to filter
The auto IR cut filter removable function controls
operation such as color picture plus infrared cut filter during
the day and black and white picture plus filter elimination at
night.
Indoor / Outdoor applications
Compact and minimal dome size allows for various install
applications
°°°°
/Sec Preset Speed
Quick Operation Keys
This camera provides quick functional keys to be easily
controllable by another controller or DVR.
Various Surveillance Functions
Auto Scan
positions with different speed and dwell time.
8 Group Tour
available and each group is consisting up to 60 presets
step with different speed and dwell time with 16
characters.
164 Preset positions
preset positions are available with 16 characters
8 Patterns
patterns are available with 16 characters and each one
consists of 50 seconds, up to total 400 seconds.
8 Sectors
are available with 16 characters
4 Privacy Masking Zones
user-defined privacy masking zones are available with
16 characters
4 Alarm input
preset, tours, patterns.
240
This camera provides up to 240°/sec of manual speed
and is adjustable from 1°/sec to 240°/sec at an interval
of 10°/sec
repeats pan and tilt between two preset
up to 8 Programmable Group tours
up to 164 programmable
up to 8 programmable user-defined
up to 8 programmable user-defined sectors
up to 4 programmable
up to 4 alarms can be activated with
°°°°
/S – Manual speed
1/4” Sony Super-HAD CCD
Equipped with Sony Super-HAD CCD technology, this
camera provides excellent sensitivity and low smear
levels.
Intelligent Pan/Tilt Controlling
Intelligent Pan/Tilt function decreases pan and tilt
speeds in proportion to zoom.
Aluminum case and PC cover
Aluminum body and Poly Carbonate dome
(IP66 Rated)
.
Password Protection
4
OVERVIEW OF PARTS
OVERVIEW OF PARTSOVERVIEW OF PARTS
OVERVIEW OF PARTS
1. Surface Mount Adaptor
2. Cap Screw ( PT3/4 , 2EA )
3. Dip Switch
4. Terminal Block
5. Main body
5
INSTALLATION
INSTALLATIONINSTALLATION
INSTALLATION
A. CONNECTION METHOD
A-1
1. Loosen the screws on the dome cover and remove it from the base.
(Screws will not fall out)
2. Loosen the screws which connect mount cover and Main base and separate dome cover from
the main base. (Screws will not fall out)
3. Connect power (12VDC or 24VAC)
4. Connect video to Video and GND.
5. Connect communication cable to RS-485 connectors.
6. Connect alarm cable to GND like 1 and GND, 2 and GND, 3 and GND, 4 and GND.
(You can use both N.O / N.C methods.)
Don’t screw too tightly. It can be the cause of a defect.
6
INSTALLATION
INSTALLATIONINSTALLATION
INSTALLATION
B. MOUNT
1. Fix the surface mount adaptor with 4pcs of screws on the place where you want to
2. When you use pipe, please note the standard size of pipe. (FIG.5)
3. Re-assemble the domes.
install. (FIG.4)
7
QQQQUICK OPERAT
UICK OPERATION
UICK OPERATUICK OPERAT
1-64 + preset and 101~200 + preset are used for preset and 65-100 + preset used for functions.
For example, to enter OSD MENU, press the button 95 + PRESET or 95 +ENTER
<Quick Operation Key Table 1, Pelco - D, P>
Number Note Function
1 ~ 64, 101~200 +Preset PRESET Executing Preset 1 ~ 64
65 + Preset PRESET STATUS Display Preset Status
66 +Preset AUTO SCAN Executing Auto Scan
67 +Preset AUTO FLIP Selectable On/Off/Auto in Auto Flip function
71~78 +Preset GROUP TOUR Executing Group Tour #1 ~ #8
81~88 +Preset PATTERN Executing Pattern #1 ~ #8
91 + Preset ZERO POSITION
92 + Preset FREEZE
93 + Preset BLC MODE Selectable On/Off in BLC function
94 + Preset D/N MODE Selectable Day/Night Mode (Auto/Day/Night Mode)
95 + Preset OSD MAIN MENU To enter OSD Main Menu
96 + Preset FOCUS ADJUST Focus adjusting
97 +Preset ALARM Selectable Enable/Disable all Alarms
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
Menu Function
Tilt Up / Down Sub menu cursor moves up / down
Pan Left / Right Enter to the sub menu or status change or decrement
Focus Near Using for Enter key when user select YES or NO
Focus Far Using for function changing keys when set coordinate
Zoom Tele Status cursor to the right
Zoom Wide Status cursor to the left
* 65 + preset: Status Report, if user presses ‘Near’ key, it disappears.
ION KEYS
IONION
KEYS
KEYSKEYS
8
QQQQUICK OPERAT
UICK OPERATION
UICK OPERATUICK OPERAT
DIAGNOSTIC
DIAGNOSTIC
DIAGNOSTICDIAGNOSTIC
When Power is on, DIAGONOSTIC is operational.
The following messages are displayed on the monitor.
CAMERA ID : 001
BAUD RATE : 2400 BPS
WAITING………
ION KEYS
IONION
KEYS
KEYS KEYS
PAN ORIGIN CHECK OK
TILT ORIGIN CHECK OK
TX CONNECTION TEST OK
CAMERA COMM TEST OK
A.
Pan Origin Test
Zero point of Pan is found after Panning test.
B.
Tilt
Origin Test
Zero point of Tilt is found after Tilting test.
C
.
TX connection Test
Countdown from 60 seconds for TX Connection Test,
During 60 seconds, the camera must receive a signal from any key of the controller or DVR.
When received the correct signal, OK is displayed after TX CONNECTION TEST.
* If “No Tested” is displayed on the monitor,
- Camera did not receive the any signal.
- Camera did receive the signal but did not correct it.
- User should check protocol, baud rate and RS-485 connection.
D.
Camera Comm. Test
Communication test with the camera is automatically checked.
OK should be displayed in these four tests before installation.
If all the above Tests are OK, “NOW EEPROM CHECKING” and “EEPROM OK” is displayed and the
camera is ready to operate.
9
10
EXIT
[REVIOUS PAGE]
[PREVIO
U
S PAGE]
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
A. OSD MENU TABLE
AUTO SCAN SET
START ANGLE : XXX.X.XX .X
END ANGLE : XXX.X.XX.X
DIRECTION : CW
ENDLESS : OFF/ON
SPEED : 10
PRESET SET
PRESET NO: 001
PRESET ID: PRESET01□□□□□□□ □□
SAVE
EXIT
PAN:XXX.X.XX.X TILT:XX X.X.XX.X
CAMERA SET
FLICKER : OFF/ON
MIRROR : OFF/ON
APERTURE : 02
D ZOOM : OFF/ON
WB MODE : ATW2 MODE
/S
°
DOME SET
RECOVER : OFF
CAMERA ID : CAM1□□□□□□□□□□□ □
SPEED : FAST
MANUAL SPEED : 100
AUTO FLIP : OFF
ZOOM
MAIN MENU
DOME SETUP
CAMERA SET
PRESET
AUTO SCAN
DWELL TIME : 03
SAVE AND EXIT
EXIT
PIC FLIP : OFF/ON
BLC : OFF/ON
D/N MODE : AUTO MODE
DSS MODE : OFF/ON
EXIT
ALARM : DISABLE
LANGUAGE : ENGLISH
TOUR
PRAVACY
EXIT
[NEXT PAGE]
SAVE AND EXIT
PATTERN
ALARM
SECTOR
SECTOR SET
SECTOR NO : 01
SECTOR ID : SECTOR01□□□
SECTOR START: XXX.X.XX .X
SECTOR END : XXX.X.XX.X
SAVE
EXIT
ALARM SET
ALARM NO. : 01
ALARM INPUT : OFF
PATTERN SET
PATT NO. : 01
PATT TITLE PATTERN01□□□
PRIVACY SET
PRIVACY NO. : 01
DISPLAY : OFF
TOUR SET
TOUR NO. : 01
TOUR TITLE : TOUR01□□□□□□
ALARM ACT : 001
SAVE
EXIT
DATA FILL : 000%
SAVE
EXIT
ACTION : MOVE
SAVE
EXIT
/S
°
EXIT
TOUR STEP : 01
PRESET NO : BLK
SAVE AND EXIT
DWELL TIME : 03
SPEED : 200
[INITIALIZATION]
[TOUR CLEAR]
[PRESET CLEAR]
[SECTOR CLEAR]
[PRIVACY CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAUL T
[SYSTEM STATUS]
PROTOCOL : PELCO D,P
BAUD RATE: 2400BPS
FIRMWARE VER.:3.00
UPGRADED DATE: 12.08.1 0
CAMERA MODULE:SCC-ZM12 3
VIDEO TYPE : NTSC
OSD DISPLAY
CAMERA ID: OFF/ON
PRESET ID: OFF/ON
SECTOR ID: OFF ON
COORDINATE:ON/OFF
[PREVIOUS PAGE]
PASSWORD
ENTER PASSWORD
BY ENTERING PRESET COD E
PASSWORD ***
CONFIRM ***
NEXT PAGE
SYSTEM LOCK : OFF/ON
[PASS WORD ]
[OSD DISPLY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
11
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
To enter OSD Menu, press the button 95 + PRESET.
MAIN MENU
DOME SETUP
PRESET
CAMERA SET
AUTO SCAN
TOUR
PRIVACY
PATTERN
ALARM
SECTOR
EXIT
*Move the joystick up / down to highlight the selection and left / right to make the selection
B. Dome Setup
To enter Dome setup, move the joystick to the right when the setting is highlighted
DOME SET
CAMERA ID : CAM1□□□□□□□□□□□□
RECOVER : OFF
MANUAL SPEED : 100°/S
AUTO FLIP : OFF
ZOOM SPEED : FAST
ALARM : DISABLE
LANGUAGE : ENGLISH
[NEXT PAGE]
SAVE AND EXIT
EXIT
DEFAULT SETTING
B-1.
To set camera ID, select up to 16 characters using Joystick to the left or right.
DOME SET - CAMERA ID
Press ZOOM TELE button to move to the next character from left to right direction and
ZOOM WIDE button to move to the next character from right to left direction
(Space displays when appears)
12
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
B-2.
B-3.
B-4.
B-5.
DOME SET - RECOVER
This feature allows the dome to recover to the last setting before the dome was used manually
(Auto scan, group tour, pattern or sectors), after the set time, power will shut down and turn back
on. Recover time can be programmed from 15 second to 90 seconds. The default setting is
OFF.
DOME SET - MANUAL SPEED
Manual Speed of Pan/Tilt is selectable from 1°/sec up to 240°/sec.
The default setting is 100°/sec
DOME SET - AUTO FLIP
Auto Flip is available and the default setting is OFF. Move joystick “right or left” to select ON or
OFF. The default setting is OFF. This function can be recalled by pushing 67+ preset button.
DOME SET – ZOOM SPEED
Zoom speeds are selectable FAST or SLOW mode. Move joystick to the right direction for
selecting FAST or SLOW. The default setting is FAST.
B-6.
DOME SET – ALARM
All alarms are available after set as ENABLE Mode. Move joystick to right or left direction for
selecting ENABLE/DISABLE. The default setting is DISABLE. This function can be recalled by
pushing 97 + preset button.
B-7.
DOME SET - LANGUAGE
Multiple languages are selectable here including English, Italian and Polish. Move joystick to the
right or left direction to select language. The default setting is ENGLISH.
B-8.
DOME SET – [NEXT PAGE]
DOME SET
SYSTEM LOCK: : OFF
[PASS WORD]
[OSD DISPLAY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
B-8-1.
DOME SET – [NEXT PAGE] – SYSTEM LOCK
Password protection allows settings to be stored. One then must enter the correct password to
change the settings. In order to enter [PASS WORD] page, system lock status is must set as ON.
Move joystick to right or left direction to select ON. The default setting is OFF.
DEFAULT SETTING
13
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
B-8-2.
DOME SET – [NEXT PAGE] – [PASSWORD]
To enter this page to set a password, SYSTEM LOCK should be ‘ON’ then move joystick to the
right direction on [PASSWORD]. The password must be set by preset number from 001 to 255
(Default 99)
A. OSD MAIN MENU TABLE (PAGE 11) The default setting is BLANK.
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***
Press any number from 001~255 with preset button on password blank and again it on confirm
blank. Then “CONFIRMED” is displayed on the monitor and the menu will go back to the previous
page automatically.
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***CONFIRMED
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***CANCELLED
B-8-3.
<CONFIRMED> <CANCELLED>
If user presses wrong preset number between PASSWORD and CONFIRM, “CANCELLED” is
displayed on the monitor and if user failed 3 times, the menu will return to the previous page
automatically * After setting a Password, an operator must enter the correct password in order to
enter OSD MAIN MENU, or to change the settings.
* An operator must remember the password for the operation. Manufacturer doesn’t provide
password recovery.
DOME SET – [NEXT PAGE] – [OSD DISPLAY]
OSD ID displayed after set ON in here and it can be hiding if selected OFF. Move joystick to the
right or left direction in order to select OFF/ON when the cursor is located each item.
14
[PREVIOUS PAGE]
OS D M
OS D MENU SETTING
OS D MOS D M
ENU SETTING
ENU SETTINGENU SETTING
OSD DISPLAY
CAMERA ID : OFF
PRESET ID : OFF
SECTOR ID : OFF
COORDINATE : ON
[PREVIOUS PAGE]
DEFAULT SETTING
B-8-4.
B-8-5.
DOME SET – [NEXT PAGE] – [SYSTEM STATUS]
This page shows the information of this camera.
PROTOCOL : PELCO D, P
BAUD RATE : 2400 BPS
FIRMWARE VER. : 3.00
UPGRADED DATE : 12.08.10
CAMERA MODULE : SCC-ZM123
VIDEO TYPE : NTSC/PAL
- Protocol and baud rate are shown according to the dip switch setting
(Refer to page 29, 30 and 31)
- Firmware version and upgraded date will be changed if upgraded.
- Below camera modules can be set as follows.
SCC-ZM123: SAMSUNG 12X ZOOM CAMERA MODULE.
SYSTEM STATUS
DOME SET – [NEXT PAGE] – [INITIALIZATION]
To clear all memorized data for tour, preset, sector, privacy or pattern, move joystick to the right
7th~8th dip switches are used for Protocol Setting.
Factory Default: Pelco-D or Pelco-P (Auto detection)
DIP SW1- 7 DIP SW1- 8
OFF OFF Pelco-D or Pelco-P
A-4. BAUD RATE SETTING
The 9th Dip Switch is used for BAUD RATE setting.
DIP SW can be changeable to 2400bps, 9600bps.
Factory Default: 2400bps.
DIP SW1 9th BAUD RATE
OFF 2400
ON 9600
.
A-5. 485 TERMINATIONS
10th Dip Switch is used for 100Ω termination.
Set on 10th Dip Switch only for the last looped camera from the controller.
Even in case of only one camera, set on 10th Dip Switch of the cameras.
27
cable is connected correctly.
If excessive light is seen on a screen, change the camera
TROUBLESHOOTING
TROUBLESHOOTINGTROUBLESHOOTING
TROUBLESHOOTING
If you have trouble in operating in your camera, refer to the following.
PROBLEM
Check if the power supply is DC12V or AC24V.
No operation
Check if RS-485 communication
Check camera ID setting.
Check the termination.
Check if all the cables are connected correctly.
No picture
Check if the monitor is adjusted correctly.
Check if video signal line is cut.
Dark screen Adjust the monitor status.
Abnormal camera
Operation status
Check if voltage level is out of the specification.
Check the termination.
Check if there is dust on the lens.
Adjust the monitor status.
Screen not clear
angle or location.
Adjust the lens focus again.
SOLUTION
28
SPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
PAN /TILT
FUNCTIONS
POWER
OTHERS
CAMERA
MODULE
MODEL
Pan Rotation Angle 360˚ Endless
Pan Speed
Tilt Rotation Angle 0˚ ~ 90˚
Tilt Speed
System Accuracy 0.02˚
Presets
Group Tour
Auto scan Programmable Auto scan
Pattern 8 Programmable Patterns (total 400 seconds)
Privacy Zone 4 privacy zones
Sector 8 selectable Sectors with 16 characters
Password Protection Yes
Alarm Input 4 alarms OFF/NC/NO (with various programmable states)
Alarm Actions Activate preset, Group scanning or Patterns
Auto Flip ON / OFF
OSD Menu Multiple Languages on screen
Communication RS-485
Protocol Pelco D/P
Power Consumption 12VDC 800mA / 24VAC 400mA
Power Supply 12VDC or 24VAC(Dual Voltage)
Construction die-casting , Anti-vandal dome cover
Dimensions 167.0φ (D) * 167.0mm(H)
Weight 1.5 kg
Motor Type Stepper Motor
Micro Steps 1/4 Step
Storage Temperature -40F~ 140F
Operating Temperature -14F ~ 120F
Image Sensor 1/4" Sony Super-HAD CCD
Total
Image
Pixels
Number Of
Effective
Pixels
Horizontal/Vertical
resolution
Lens
Day & Night (ICR) Auto/ Day/ Night
Min. Shooting Distance 0.2m(Wide)/0.8m(Tele)
Digital Slow Shutter 2/4//6/8/12/16/24/32/48/64/96/128/256/ OFF
Min.
illumination
(F1.6/Wide)
Luminance S/N Ratio More than 52dB
Video Output VBS:1.0Vp-p/75 Ohm
BLC ON / OFF
Flickerless ON / OFF
WHITE BALANCE
Manual 1˚ ~ 240˚/sec
Preset Max 240˚ /sec
Manual 1˚ ~ 240˚/sec
Preset Max 240˚ /sec
164 positions with a 16-character label available for each position
Max. 8 Programmable group tours (each one consisting of up to 60 preset steps
NTSC 811(H) * 508(V)
PAL 795(H) * 596(V)
NTSC 768(H) * 494(V)
PAL 752(H) * 582(V)
More Than 560(Color) / 600(BW) TV Lines
Optical
Digital 12x (144x with optical)
Color
mode
Night
mode
12x Optical Zoom(f=3.6 to 44.3mm,
0.008 Lux (50IRE, Sens x256)
0.0008 Lux (50IRE, Sens x256)
ATW1/ATW2/INDOOR/OUTDOOR
HTSD12X
with different speed steps
with different steps)
F1.6(Wide)/F2.0(Tele)
29
DIMENSIONS
DIMENSIONS
DIMENSIONSDIMENSIONS
30
31
32
Speco Technologies is constantly developing product improvements.
We reserve the right to modify product design and specifications
without notice and without incurring any obligation. (Rev. 130328)
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.