SpaNet SV2 Quick Reference Manual

Page 1
03/ UV
SV-2T
UP BUTTON
Short single presses toggle through the three display modes: W.TMP = Water Temperature, S.TMP = Set Temperature, TIME = Clock.
Holding the button will force the controller to begin adjusting the set temperature and will raise the set temperature point.
Also used for adjusting settings.
DOWN BUTTON
Short single presses toggle through the three display modes: W.TMP = Water Temperature, S.TMP = Set Temperature, TIME = Clock.
Holding the button will force the controller to begin adjusting the set temperature and will lower the set temperature point.
Also used for adjusting settings.
SANITISE BUTTON
Press once to activate a 20 minute sanitisation and clean up cycle to refresh water quality after spa use. A second press will cancel the cycle if already running.
WATER TEMP / TIME BUTTON
A shortcut key designed to quickly toggle between actual water temp and time display modes.
OK BUTTON
Used to confirm and save setting adjustments or to enter setting adjustment menus.
SLEEP TIMER INDICATOR LED
This LED will turn on when the controller is in a sleep mode.
SANITISER INDICATOR LED
This LED will turn on to indicate that the ozone or uv sanitiser unit is operating (if fitted).
HEATER INDICATOR LED
This LED will turn on when the heater or heat pump (if fitted) is operating.
AUTOMATIC INDICATOR LED
This LED will turn on whenever the filtration pump is in automatic mode.
LIGHT BUTTON
Press to toggle spa lights on / off. When light is first turned on the user has the ability to adjust the light effect mode or colour via the up, down & OK buttons.
BLOWER BUTTON
Press to toggle blower on/off. A single press turns blower on in vari-speed mode. Use up & down buttons to vary speed. A double press activates the ramping mode.
PUMP B BUTTON
Used to toggle any additional jet pump on / off (if fitted).
PUMP A BUTTON
Used to toggle the filtration pump on / off / auto.
QUICK REFERENCE GUIDE
AM PM
OFF ON
°C °F
MODE SPD BRT
SAT SUN MON TUE WED THU FRI
MENU ICONS
Sleep timer menu icon
Light menu icon
Blower menu icon
40.00
STATUS ICONS
Keypad locked
Sanitise cycle operating
OFF ON
POWER SMART
Filtration cycle operating
Fault condition has occured
DISPLAY MODE ICONS
Water Temperature
Set Temperature
Clock
Page 2
CHANGING LIGHT MODES PARTIAL KEYLOCK [FILT] DAILY FILTRATION TIME Once P.SAV mode is selected the begin
and end times of the PEAK power tariffs When light is first turned on the keypad Press and hold this button combination Adjust the hours of filtration per day. must be set so the control knows NOT will display the light mode menu until LOCK appears on the display: Filtration limits differ for type of pump: to operate during those peak hours. showing current light mode in use.
Circ Pump (2A or less) 1-24 hrs
BGN Peak power begin time
Jet Pump (2spd or 1spd) 1-8 hrs
END Peak power end time
Press or button to step
Repeat button combination to unlock.
through choice of light modes:
[F.CYC] FILTRATION CYCLES
[W.CLN] AUTOMATIC SANITISE
Note: Once locked only pumps, blower, light
WHTE White Light
and sanitise buttons can be used. Access
This setting defines how often filtration
Adjust the start time of the 10 minute
UCLR User Colour
to all other buttons is disabled.
cycles occur. Filtration can be set to run
automatic daily sanitise cycle. Setting
FADE Fade Effect
every 1/2/3/4/6/8/12 or 24 hrs
can be adjusted from 0:00 to 23:59.
STEP Step Effect
SETUP MENU
Press button to confirm light
[SNZE] SLEEP TIMERS
[D.DIS] DEFAULT DISPLAY MODE
mode selection.
The setup menu allows customisation
Used to disable automatic heating and
of the adjustable controller settings.
Used to adjust the default display mode
filtration during certain times of day or
Dependant on light mode selected the
Menu access and item adjustments are shown on the keypad. Setting choices:
night. Upon entering SNZE menu there
keypad will then display one of three
carried out as follows:
W.TMP Water Temperature
are four choices:
light mode option screens.
S.TMP Set Temperature
Press and hold and buttons
TIME Clock
1.SNZ Sleep Timer #1
CL:xx User Colour Number
together until [MODE] is displayed.
2.SNZ Sleep Timer #2
L.SPD Light Transition Speed
R.SET Reset timers to default
L.BRT Light Brightness
[T.OUT] LOAD TIME OUTS
Press or to navigate through
EXIT Exit sleep timer menu
setup menu items.
All accessory loads (pumps & blowers)
Press or button to adjust
Only one sleep timer needs to be set
automatically turn off after a time out
however two timers are provided to
each setting.
Press to enter item adjustment.
period has elapsed. Adjust the time out
facilitate different sleep settings on
period from 10-60 minutes.
different days. Each sleep timer setting
Press button to save each setting
Press or to adjust setting.
consists of a week day setting, start
and move to the next setting.
time and stop time (refer below).
[H.PMP] HEAT PUMP MODE
Press to confirm setting and exit.
Note: All light settings are saved for
x.DAY Day(s) of operation
Defines heat pump operating mode:
All setup menu items follow the same
future ON / OFF use.
x.BGN Sleep timer begin time
adjustment procedure. Menu items that
AUTO Heat & Cool
x.END Sleep timer end time
can be adjusted are as follows:
HEAT Heat Only
Use the Up, Down & OK buttons to
FULL KEYLOCK
COOL Cool Only
adjust and confirm each setting.
OFF Heat Pump Disabled
[MODE] OPERATING MODES
Press and hold this button combination until LOCK appears on the display:
[P.SAV] POWER SAVE (off peak)
Operating modes effect heating and
[H.ELE] ELEMENT BOOST
filtration behaviour. The choices are:
Reduce operating costs by limiting
Enables/disables SV electric element to
filtration and heating to occur during
NORM Normal heating & filtration
boost heat pump heating if the water Repeat button combination to unlock.
o
ECON Heating only during filtration
cheaper off peak power periods. There
temperature is 2 C or more below set
AWAY Heating disabled. Filtration
are three P.SAV modes:
temperature point OR the heat pump
Note: Once locked if any button is
reduced to 1hr p/day.
OFF P.SAV disabled
has been operating for more than 1hr.
pressed the key stroke will be ignored
WEEK Mon-Thu (works like AWAY mode)
LOW Off-peak filtration only
and the display will show LOCK.
Fri-Sun (works like NORM mode)
OFF Element disabled (heat pump only)
HIGH Off-peak filtration & heating
ON SV element + heat pump
up
down
pump a
+ +
up
down
pump b
+ +
Loading...